® OPERATING INSTRUCTIONS HyPro-6 HyPro-8 USA/Canada USA/Canada Receiver R-18, R-CAN Compact-M, Compact-M2 Compact-V, PNN-BUS-3 Receiver Type / Version Transmitter Type Factory No. Factory No.
1. STANDARD SPECIFICATION % Portable transmitter. % Receiver with integrated mounting holes. % Optional: Multi-pin connecting cable for the receiver according to your specifications. The actual delivery specification is as detailed on the confirmation of order or the delivery note accompanying the goods! 2. SAFETY PRECAUTIONS Even if you are accustomed to working with radio control systems, read these operating instructions carefully before using this equipment.
. TRANSMITTER HyPro DISPLAY BATTERY DISPLAY RADIO ON EM-STOP The power supply of the transmitter is activated with the EMERGENCY STOP switch. When pressed, the EMERGENCY STOP switch can also be secured by removing the key cap. START An antenna symbol is active in the display during operation. BATTERY / ACCUMULATOR State of charge OPERATION will be shown in the LC-display. Commands can now be put in by means of the controls. 1 2 3 4 5 Battery status is shown in the LC-display.
BATTERY CHARGER L-AD72A2 For charging NiCd and NiMH batteries (7,2V). Optional: Integrated battery charger if DC-supply: In the receivers R-18, R-CAN, Compact-M and Compact-V rapid charging in about 1 hour. In PNN-BUS-3 about 3 hours. Use this battery charger only in closed rooms. Operating instructions 2.250.1449 Universal-charger (12V/24V DC), (without cable), black 2.250.1450 Universal-charger (2.250.1449) (12V/24V DC) set with 2m cable, black, pluggable with plug Europe (3.970.
Battery Before first use, fully charge batteries! To prevent damage to the batteries never use discharged batteries! Only charge fully discharged batteries! Therefore please work with your control until the capacity of the battery is totally exhausted. The battery reaches the maximum energy storage capacity only after at least 5 times charging and discharging completely! Discharge the battery completely in the operating unit before charging once more. The charging time depends on the type of battery.
4. OPERATING THE UNIT Safety equipment in the NBB-radio remote control: In the transmitter, this comprises mainly: % STOP resp. EMERGENCY STOP, with automatic disconnection of the power supply. % Automatic zero positioning. In the receiver: % Automatic zero setting when switching back on after radio interruption. % Locking of the radio commands at relay level in the event of a defective STOP, circuit.
5. RECEIVER R-18, R-CAN, Compact-M, Compact-M2, R-18 R-CAN Compact-V PNN-BUS-3 Compact-M Compact-M2 Compact-V PNN-BUS-3 Mounting possibility of the receiver R-18, R-CAN,Compact-M. The receiver is connected to the unit to be controlled with the multi-pin connecting cable supplied.
6. FUNCTION CHECK To maintain operational safety, a regular function check of the NBB radio remote control is necessary. In single-shift day-to-day operation, we recommend performing this check at least once a week. Checking is possible using the display lights provided on the receiver. To do so, the transmitter must be set to the ready-to-operate state. % First connect just the receiver - the transmitter remains switched off. % Activate the transmitter by unlocking the EMERGENCY STOP switch, resp.
Checking the LED's at the receiver Compact-V: LED 1 green: POWER ON. If LED fails to come on, check the power supply. If the power lead is OK, call in the after-sales service. LED 2 yellow: HF PRESENT. Steady light when transmitter is switched on (insignificant for scanner operation). LED 3 green: Flashes evenly during fault-free operation. Irregular flashing means that the HF channel is probably at fault - please set another channel.
7. IDENTIFICATION PLATES The identification plates state the type of transmitter or receiver, the factory number, the frequency range and the approval number for non EU countries. Always state the factory number in all your queries. Example: Transmitter Type / Version: HyPro Factory No.: 999 899 4990 Frequency: Mhz X X 8. MAINTENANCE 9. WARRANTY 10. IN CASE OF DEFECTS Receiver Type / Version: Compact-V Factory No.
. US-FCC and CANADA IC USA: NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
TECHNICAL DATA ® Operating ambient temperature -20 to +70 °C Insulation class - Protection IP 65 TRANSMITTER HyPro-6, HyPro-8 Transmission frequency range see rating plate Spacing 25 Khz The use of synthesizer technology permits frequencies to be selected in accordance with the appropriate waveband for the country of use. Low frequency modulation GFSK Data repetition rate about 15 ms / 60 ms Baud rate 1200 - 9600 Baud (Bit / sec.
APPROVALS AND CERTIFICATES Approvals EU countries: X X Enclosure: EC Declaration of Conformity Obtainable at demand: M-Zert mbH Certificate DIN EN ISO 9001:2008 © NBB Controls + Components GmbH Otto-Hahn-Straße 3-5 DE-75248 Ölbronn-Dürrn Tel.: 0 72 37 / 9 99 - 0 Fax: 0 72 37 / 9 99 - 1 99 eMail: sales @ nbb.de http://www.nbb.de We reserve the right to alter specifications without notice. Bedienungsanleitung HyPro-6, HyPro-8, R-16, R-CAN, Compact-M, Compact-V, Englisch, Teile-Nr. 3.150.1251, Stand 04.