WAY-UNIVKF - The 2-Way Universal LCD Keyfob that puts the power of a keypad in your pocket. Easy LCD ICON Indicators Burglar Alarm Fire Alarm Armed - Away Armed - Stay Armed - Instant NAPCO introduces the new 2WAY-UNIVKF, the security industry’s only universal bidirectional Keyfob with LCD status display and integral mini sounder, supported by a revolutionary 2-way receiver.
TABLE OF CONTENTS Section General Description Page GENERAL DESCRIPTION..............................................3 SYSTEM OVERVIEW .....................................................4 WIRING DIAGRAM/ CONFIGURATION .........................5 CONTROLS AND AUDIBLE INDICATORS.....................6 VISUAL INDICATORS ....................................................7 BUS MODE WIRING AND CONFIG ...............................8 BUS MODE ENROLLING KEYFOBS .........................
SYSTEM OVERVIEW General Information The 2WAY-UNIVKF is compatible with virtually any control panel, either through keypad bus operation or universal mode operation. When used on a panel on which it is buscompatible, full functionality is realized, including lighting, appliance and X10 control.
WIRING DIAGRAM AND SYSTEM CONFIGURATION Enroll Mode Push Button Receiver LED A1 A2 A3 AR R2T RE1 RE2 RE3 RE4 RES System Configuration Jumpers J10 J9 J8 Keypad Address Jumpers B Mounting the Receiver The 2 way receiver should be mounted in a location which is centrally located within the area of anticipated usage. It is not recommended that the receiver be installed in an attic or mounted within 24 inches of any metallic objects. Installation in a basement will result in reduced range.
CONTROLS AND INDICATORS Controls The KeyFob’s 4 command buttons provide complete system control. Commands are issued to the alarm system by either pressing or holding down (for 2 seconds) the appropriate button. Audible Indicators Each time a command is issued, the KeyFob’s mini sounder will issue an audible confirmation beep with the visual indication. General Information # of Beeps Status 1 Armed Press ∗ to open garage door 2 Disarmed Hold Down PANIC for 2 seconds to activate a panic alarm.
CONTROLS AND INDICATORS Visual LCD Indicators The 2WAY-UNIVKF uses a series of icons to convey the status of the system. Each time the STATUS button is pressed, or a command is issued, the appropriate icon(s) will display for about 6 seconds. For example, if ON/OFF is pressed to arm the system, the Armed icon will light in a few seconds to confirm that the command was successfully performed. Below is a description of each icon indicator.
STEP 1 - WIRING AND CONFIGURATION Bus Mode Operation If KeyFob panic is desired, Keypad Panic should be enabled in the control panel program. For the Ademco Vista 10 and 20, zone 95 must be programmed for 24 Hr Audible or 24 Hr Silent. For the Vista 40 & 50 zone 99 must be programmed for 24 Hr Audible or 24 Hr Silent.
STEP 2 - ENROLLING KEYFOBS--With NAPCO "Classic" Keypads Enrolling and Removing KeyFobs Each KeyFob must be enrolled into the receiver. The following procedure is used to enroll the unique RF ID number stored in the non-volatile memory of each KeyFob into the receiver memory. Arm system from any keypad 2 Disarm system from any keypad 3 Press 1114 D on keypad The Enroll Mode LED will flash rapidly. The keypad will give error beeps - ignore.
STEP 2 - ENROLLING KEYFOBS--With NAPCO "K Series" Keypads Bus Mode Operation Enrolling and Removing KeyFobs Each KeyFob must be enrolled into the receiver. The following procedure is used to enroll the unique RF ID number stored in the non-volatile memory of each KeyFob into the receiver memory. 1 Arm system from any keypad 2 Disarm system from any keypad 3 Press 1114 U on keypad The Enroll Mode LED will flash rapidly. The keypad will give error beeps - ignore.
STEP 2 - ENROLLING KEYFOBS--With ADEMCO Panels/Keypads Enrolling and Removing KeyFobs Each KeyFob must be enrolled into the receiver. The following procedure is used to enroll the unique RF ID number stored in the non-volatile memory of each KeyFob into the receiver memory. Arm system from any keypad 2 Disarm system from any keypad 3 Press 1114, then [AWAY] on keypad The Enroll Mode LED will flash rapidly. The keypad may sound error beeps* - ignore.
STEP 3 - ENROLLING USER CODES--With NAPCO "Classic" Keypads Bus Mode Operation Enrolling User Codes into the 2 Way receiver After all KeyFobs have been enrolled as described in step 2, a 4-digit User Code must be enrolled into the receiver for each KeyFob. If you have enrolled 3 KeyFobs, you must program into the control panel (3) 4-digit User Codes and then use the following procedure to enroll these User Codes into the receiver.
STEP 3 - ENROLLING USER CODES--With NAPCO "K Series" Keypads Enrolling User Codes into the 2 Way receiver After all KeyFobs have been enrolled as described in step 2, a 4-digit User Code must be enrolled into the receiver for each KeyFob. If you have enrolled 3 KeyFobs, you must program into the control panel (3) 4-digit User Codes and then use the following procedure to enroll these User Codes into the receiver.
STEP 3 - ENROLLING USER CODES--With ADEMCO Panels/Keypads Enrolling User Codes into the 2 Way receiver After all KeyFobs have been enrolled as described in step 2, a 4-digit User Code must be enrolled into the receiver for each KeyFob. If you have enrolled 3 KeyFobs, you must program into the control panel (3) 4-digit User Codes and then use the following procedure to enroll these User Codes into the receiver.
GARAGE DOOR CONTROL / SPECIAL APPLICATIONS When installed on the bus of a Gemini or Ademco control panel, receiver Relays 1 and 2 are available for other applications such as lighting or appliance control, while Relay 3 remains dedicated to the control of a garage door opener. • Press [ON/OFF] and [∗] simultaneously to toggle Relay 1 On / Off • Hold Down [∗] for 2 seconds to toggle Relay 2 On / Off OR • Hold Down [∗] for 2 sec. to momentarily activate Relay 2 to open a second garage door.
TYPICAL APPLICATIONS Typical Gemini control panel application controlling 2 Garage doors and X-10 devices and appliances through the 2WAY-UNIVKF Keyfob. Typical Ademco control panel application controlling 1 Garage door and 2 appliances through the 2WAYUNIVKF Keyfob.
STEP 1 - WIRING FOR ARM / DISARM AND PANIC Universal operation requires the use of control panel zones to provide Arm / Disarm and Panic operation. One zone must be programmed as a keyswitch arm zone which will process a 2 second violation as an Arm / Disarm command. The other zone must be programmed as a 24 hour panic zone, which will process a 2 second violation as a panic alarm.
STEP 2 - ENROLLING KEYFOBS Enrolling and Removing KeyFobs Each KeyFob used in the system must be enrolled into the receiver using the following procedure: # Enroll Mode Push Button Enroll Mode LED Universal Operation Receiver 1 Use a pen or pencil to depress and hold the recessed Enroll Mode Push Button on the top of the receiver. Entered Enroll Mode - The Enroll Mode LED will continue to flash. 2 Press the ∗ button on KeyFob 1. The KeyFob will sound a single confirmation beep.
STEP 3 - WIRING FOR ARM & ALARM SENSE Wiring for Arm Sense Wiring for Alarm Sense In Universal Mode, the receiver requires an Armed output from the control panel in order to pass the system status to the KeyFob. It may be configured for either a positive sense or negative sense. In Universal Mode, the receiver requires an Alarm output from the control panel in order to pass the correct status to the KeyFob. Typical connection will be to the bell output of the control panel.
Wiring for Stay Mode Universal Operation Wiring for Stay Mode When installed on a control panel which provides “Automatic Interior Bypass”, the system can be armed in either the AWAY or STAY mode through the KeyFob. A system which provides “Automatic Interior Bypass” controls the Interior protection by automatically bypassing the Interior Zones if the system is armed and the exit/entry door is not opened.
GARAGE DOOR CONTROL Wiring for Garage Door Control • Typical wiring for a controlling a garage door opener from KeyFob. N/O 14 1 Open battery compartment on back of Keyfob. 2 Remove old battery and replace with new. + AAA COM N/C 15 16 Garage door opener wall mounted push-button switch, or normally open garage door opener input.
TYPICALDOOR APPLICATIONS GARAGE CONTROL Typical Universal Mode applications with EOLR Control Panel (MA1008e) and Zone Doubled Control Panel (GEM-P800) using Arm and Alarm sense with Stay Mode and Garage Door control. E4 ARMED LUG 4 E10 Burg LUG 8 REM. PWR GEM-P800 - 9 Z2 Z3 Z4 Z5 Z6 Z7 Z1/2 Z3/4 13 14 15 16 17 18 19 20 21 22 23 24 25 26 - + + + - + 2 Z5/6 + - + + - 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1 2 3 5 6 6 STAY MODE PGM (4) 7 7 (3) 8 VVV 3.
TYPICALDOOR APPLICATIONS GARAGE CONTROL Typical Universal Mode applications with EOLR Control Panels using Arm and Alarm sense with Stay Mode and Garage Door control. Z1 + Z2 + + Z3 - Z4 + + Z5 - Z6 + + Z7 - Z8 + 1 2 3 4 5 6 7 8 9 10 6 7 10 11 12 13 14 15 16 2WAY-UNIV 9 MODE PGM (4) 8 10 11 12 13 14 15 16 2WAY-UNIV 9 Garage Door Control 8 (4) Enable Automatic Interior Bypass for all Interior zones.
NAPCO LIMITED WARRANTY NAPCO SECURITY SYSTEMS, INC. (NAPCO) warrants its products to be free from manufacturing defects in materials and workmanship for thirty-six months following the date of manufacture. NAPCO will, within said period, at its option, repair or replace any product failing to operate correctly without charge to the original purchaser or user.