xxxxxx HiLine LV manual_Layout 1 27/06/2011 09:39 Page 2 Installation, Operating, Maintenance and After Sales Manual. HI-LINE LV Fan Convector Model: 7-4 heatingthroughinnovation. 01.02.2010 ISSUE 3 Product Serial Number: Please leave this manual with the end user.
xxxxxx HiLine LV manual_Layout 1 27/06/2011 09:39 Page 3 Contents 1.0 General Information 03 2.0 Heating System Design 03 3.0 Unit Selection/Sizing 03 4.0 Location 03 5.0 Preparation 04 6.0 Fixing 04 7.0 Water Connections 04 8.0 Electrical Connection 9.0 Commissioning Procedure 05 10.0 Technical Data 06 11.0 Operating Instructions 06 12.0 Troubleshooting 06 13.
xxxxxx HiLine LV manual_Layout 1 27/06/2011 09:39 Page 4 HI-LINE LV Fan Convector 03 l The minimum side clearance is 100mm. l The HI-LINE LV should only be used on closed circulation, two pipe, pump assisted central heating systems. l Before proceeding with the installation, the heating system design must be considered and the unit correctly sized to meet the heat loss requirements of the room at normal fan speed.
xxxxxx HiLine LV manual_Layout 1 27/06/2011 09:39 Page 5 04 HI-LINE LV Fan Convector 5.0 Preparation Before proceeding with the installation, unpack the carton contents and check against the checklist below: 1. HI-LINE LV unit. 2. 15mm isolating valves (1 pair). 3. Instruction manual. 4. Warranty card. 5. Fixing kit (rubber mounts, cable gland and equipotential bond pipe clamp). 6. Transformer. 6.0 Fixing l Using the fixing dimensions below (see fig. 2), mark the fixing hole positions on the wall.
xxxxxx HiLine LV manual_Layout 1 27/06/2011 09:39 Page 6 HI-LINE LV Fan Convector 05 8.0 Electrical Connection WARNING: The electrical installation must comply with local or national wiring regulations. l This unit is supplied with a 2m long mains cord.
xxxxxx HiLine LV manual_Layout 1 27/06/2011 09:39 Page 7 06 HI-LINE LV Fan Convector 10.0 Technical Data Heating Performance Data Temperature Difference (°C) Model 7-4 Heat Output (watts) Fan Speed 20° 30° 40° Normal 352 541 734 Boost 645 991 1344 50° Heat Output (Btu/h) 60° 20° 30° 40° 50° 60° 930 1128 1201 1846 2504 3173 3849 1702 2065 2201 3381 4586 5807 7046 Heat outputs tested in accordance with BS 4856 Part 1. Flow rate 340 ltr/h (75 gal/h).
xxxxxx HiLine LV manual_Layout 1 27/06/2011 09:39 Page 8 HI-LINE LV Fan Convector 12.0 Troubleshooting 07 (continued...
xxxxxx HiLine LV manual_Layout 1 27/06/2011 09:39 Page 1 MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk heatingthroughinnovation. After Sales Service: Spare parts and technical help on all Convector products are available from MYSON Service. 01.02.2010 ISSUE 3 MYSON Service, Somerden Road, Hull, East Yorkshire HU9 5PE T: 01482 713927, F: 01482 789056, service.convectors@myson.co.