User Instructions V-TEC io1 Smart Hook PFL Fall Protection Order No.: 10215637_r0 Print Spec: CR: 8000000XXXX MSAsafety .
WARNING! Read this manual carefully before using or maintaining the device. The device will perform as designed only if it is used and maintained with the manufacturer's instructions. Otherwise, it could fail to perform as designed, and persons who rely on this device could sustain serious injury or death. The warranties made by MSA with respect to the product are voided if the product is not installed and used in accordance with the instructions in this manual.
US Contents 1 Safety Regulations 1.1 Correct Use 1.2 Warnings 4 4 4 2 Description 2.1 Physical Contents 6 6 3 Specifications 3.1 Physical Specifications 7 7 3.2 Electrical Specifications 7 4 Installation 4.1 Installing the V-TEC io1 9 9 5 Operation 5.1 Using the V-TEC io1 System 5.
1 Safety Regulations 1 Safety Regulations 1.1 Correct Use US The V-TEC io1 Smart Hook Personal Fall Limiter (PFL) (V-TEC io1) is intended for use as part of a complete personal fall protection system. The V-TEC io1 is intended to provide real-time audible and visual feedback to users, relaying their connection status to their PPE. The V-TEC io1 is intended for use in applications where connections will be made with overhead-mounted personal fall limiters.
US 1 Safety Regulations anchor point as illustrated in Figure 2. Failure to connect in accordance with instructions may result in damage or failure of the device. • Ensure both V-TEC io1s connectors are compatible with the attachments to which they are connected (to prevent roll-out), and are fully closed and locked before use. See Table 1 for system requirements.
2 Description 2 US Description • The V-TEC io1 consists of a V-TEC PFL and a permanently integrated Smart Hook component on the snaphook that monitors and communicates connection status between the snaphook and a “tagged’ harness. • Motion wakes the V-TEC io1 from sleep mode. During wake-up, an initial alarm sound beeps once to give the initial reminder to connect. • If a connection is present when awake, the V-TEC io1 will pulse a single green LED indicating good connection.
US 3 Specifications 3 Specifications 3.1 Physical Specifications Capacity 310 lbs (141 kg) Anchorage Strength 3,6000 lbf (16 kN) Dimensions 13.5" x 3.4" x 2.75" Product Weight V-TEC io1 PFL only: Entire Product Kit: Standards ANSI Z359.14-2014 CSA Z259.2.2-98 OSHA 1910.140, OSHA1926.503 FCC 3.2 Electrical Specifications Component 24V Converter Specification Input Range: 8V - 40V DC via 16AWG wires Output Voltage: 5V DC Output Current: 2.
3 Specifications US Component V-TEC io1 Smark Hook Specification Input: USB C 5V Battery Capacity: 350mAh LiPo/nom. 3.
US 4 Installation 4 Installation 4.1 Installing the V-TEC io1 <> <> (1) Disconnect power from the Powered Industrial Truck (PIT) electrical system. (2) Remove the access panel/s over the control area. Find the open power receptacle and clean as needed. (3) Plug the input end of the power cord into the available power source. The white-striped wire of the power cord is positive (+) and must be hardwired to a power source of 12-24 V.
4 Installation <> <> US (8) Connect the 10’ USB cable to the USB C port on the back of the io1 hook. (9) Route the cable back to the right cabin pillar and secure it in the upper corner near the roof leaving some slack in the cable as shown. NOTE: Use the provided cable ties and peel and stick cable tie mounts as needed.
US 5 Operation 5.1 Using the V-TEC io1 System 5 Operation Connecting the Snaphook to the D-ring Attach the snaphook to the D-ring. NOTE: When contact is made, the smart device on the snaphook will play a "connection" tri-tone sound and an LED will gently pulse green. WARNING! Ensure the snaphook turns green. Failure to follow this warning can result in serious personal injury or death.
6 Inspection 6 US Inspection Inspection Component Inspect For: Smart Hook Case Inspect for cracks, dents, and chipping. Alarm Sounding Hole Inspect for debris blocking alarm hole (remove if present), Confirm Alarm sounds according to 'Hook Behavior' Chart above. Charging Line Inspect charging line and verify they are free of any cuts or abrasions. The cables should be fully secured at the each connection point and there should be no loose portions of wire.
US 7 7 Troubleshooting Troubleshooting If the V-TEC io1 is not working, perform a hard reset. See Table 1 for status indicators. Press the reset button on the side of the Smart Hook plastic housing with a small paperclip to turn it off. Do this again to turn the Smart Hook back on.
8 Warranty 8 US Warranty Express Warranty – MSA warrants that the product furnished is free from mechanical defects or faulty workmanship for a period of one (1) year from first use or eighteen (18) months from date of shipment, whichever occurs first, provided it is maintained and used in accordance with MSA’s instructions and/or recommendations.