Specification Sheet

NOTE: FOR ILLUSTRATIVE PURPOSES ONLY.
IMPORTANT: See Mr.Steam
®
Installation, Operation and Maintenance Manual, PUR 100376
and CU Steamstop Installation Instructions, PUR 100451, for details.
Click here to download this manual:
http://mrsteam.com/products/technical-downloads.html
mr
.
steam
®
steambaths Technical Specifications
CU Steam Stop
The CU Steamstop is an emergency stop
switch to electronically shut down the steam
generator. Multiple stop switches can be used
with one generator.
Water resistant IP-
69
K rating suitable for use in-
side or outside the steam room
Used to turn off steam solenoid(s)
Installation must conform to National and local
electrical codes
Accepts
¼
&
½
NPT; M
16
& M
20
; and Pg
13.5
& Pg
16
conduit and fittings
LOCATION AND INSTALLATION
The CU-STEAMSTOP shall be positioned for easy
access by the attendant or user.
ELECTRIC SHOCK HAZARD.
Disconnect all power supplies at the main discon-
nect switch before proceeding with wiring of the
CU-STEAMSTOP. All electrical wiring must be
installed by a qualified, licensed electrician in
accordance with National and local codes.
OPERATION AND USAGE
Pressing the CU-STEAMSTOP button will stop the
flow of steam into the steam room.
NOTE: When used with a Digital
1
Control, the
Digital
1
internal alarm (or CU-ALARM if equipped)
will sound if the CU-STEAMSTOP is pressed.
Steam will flow from the steam-
head as soon as the CU-STEAMSTOP is reset.
Refer to CU Steam Stop Installation Instructions,
PUR
100451
for complete installation
details and instructions.
!
CAUTION
!
WARNING
Fitting Drill Size
1/4” NPT 35/64”
M16 41/64”
M20 51/64”
Pg 13.5 53/64”
1/2” NPT 27/32”
1/2” NPT 27/32”
Pg 16 29/32”
Hole Marking
M16
M20
(Pg 13.5)
Pg 16