Specification Sheet
NOTE: FOR ILLUSTRATIVE PURPOSES ONLY.
IMPORTANT: See Mr.Steam
®
Installation, Operation and Maintenance Manual, PUR 100376
and CU Steamstop Installation Instructions, PUR 100451, for details.
Click here to download this manual:
http://mrsteam.com/products/technical-downloads.html
mr
.
steam
®
steambaths Technical Specifications
CU Steam Stop
™
The CU Steamstop is an emergency stop
switch to electronically shut down the steam
generator. Multiple stop switches can be used
with one generator.
• Water resistant IP-
69
K rating suitable for use in-
side or outside the steam room
• Used to turn off steam solenoid(s)
• Installation must conform to National and local
electrical codes
• Accepts
¼
” &
½
” NPT; M
16
& M
20
; and Pg
13.5
& Pg
16
conduit and fittings
LOCATION AND INSTALLATION
The CU-STEAMSTOP shall be positioned for easy
access by the attendant or user.
ELECTRIC SHOCK HAZARD.
Disconnect all power supplies at the main discon-
nect switch before proceeding with wiring of the
CU-STEAMSTOP. All electrical wiring must be
installed by a qualified, licensed electrician in
accordance with National and local codes.
OPERATION AND USAGE
Pressing the CU-STEAMSTOP button will stop the
flow of steam into the steam room.
NOTE: When used with a Digital
1
Control, the
Digital
1
internal alarm (or CU-ALARM if equipped)
will sound if the CU-STEAMSTOP is pressed.
Steam will flow from the steam-
head as soon as the CU-STEAMSTOP is reset.
Refer to CU Steam Stop Installation Instructions,
PUR
100451
for complete installation
details and instructions.
!
CAUTION
!
WARNING
Fitting Drill Size
1/4” NPT 35/64”
M16 41/64”
M20 51/64”
Pg 13.5 53/64”
1/2” NPT 27/32”
1/2” NPT 27/32”
Pg 16 29/32”
Hole Marking
M16
M20
(Pg 13.5)
Pg 16