CU Steam Stop Installation Instructions
1.8 Nm
15.9 lb-in
mr
.
steam
®
Model CU-STEAMSTOP
___________________________________________________________________________________
signals a situation where minor injury or product
damage may occur if you do not follow instructions.
IMPORTANT NOTE:
THIS HIGHLIGHTS INFORMATION THAT IS ESPECIALLY
RELEVANT TO A PROBLEM-FREE INSTALLATION.
IMPORTANT NOTE:
As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient
installation and operation of this AromaFlo. These are two types of potential hazards that may occur during this installation and operation:
states a hazard which may cause serious injury
or death if precautions are not followed.
WARNING
!
CAUTION
!
PACKAGE CONTENTS:
Steam Stop Button
30ft of Low Votage Wire
Installation Instructions
The CU-STEAMSTOP is an emergency stop button that can be
used to shut down the steam generator in the event of an
“emergency. Multiple CU-STEAMSTOPs can be installed on one
Mr. Steam CU steam generator.
CU-STEAMSTOP buttons can be installed inside and outside
of the steam room.
When installed inside the steam room (or any wet location)
only Liquid-Tite, non-metalic fittings and conduit must be used
(not supplied). Non-metalic conduit must be used when
installing the CU-STEAMSTOP outside of the steamroom.
Metalic conduit shall not be used to rout the CU-STEAMSTOP
wires. The CU-STEAMSTOP accepts ¼ & ½ NPT; M16 & M20;
and Pg 13.5 & Pg 16 conduit and fittings.
Locating the CU-STEAMSTOP
1. The CU-STEAMSTOP shall be positioned for
easy access by the attendant or user.
2. Remove the switch cover and use the 4 outer
holes in the box to mark the mounting screw
locations.
3. With the cover off, remove the internal switch
mechanism as shown.
4. Select which conduit location in the box to use
and carefully drill out the opening according to
what conduit / fitting size you will use based on
the chart to the right.
5. Replace the internal switch mechanism to the
middle position in the CU-STEAM stop.
6. Securely fasten the CU-STEAMSTOP to the wall.
Fitting Drill Size
1/4” NPT 35/64”
M16 41/64”
M20 51/64”
Pg 13.5 53/64”
1/2” NPT 27/32”
1/2” NPT 27/32”
Pg 16 29/32”
Hole Marking
M16
M20
(Pg 13.5)
Pg 16