UC-8100A-ME-T Series Hardware User’ s Manual Edition 1.0, January 2019 www.moxa.com/product © 2019 Moxa Inc. All rights reserved.
UC-8100A-ME-T Series Hardware User’ s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement. Copyright Notice © 2019 Moxa Inc. All rights reserved. Trademarks The MOXA logo is a registered trademark of Moxa Inc. All other trademarks or registered marks in this manual belong to their respective manufacturers.
Table of Contents 1. Introduction...................................................................................................................................... 1-1 Model Descriptions..............................................................................................................................1-2 Package Checklist...............................................................................................................................1-2 Product Features ..........................
1 Introduction The UC-8100A-ME-T computing platform is designed for embedded data acquisition applications. The UC-8100A-ME-T platform comes with two RS-232/422/485 serial ports and dual 10/100 Mbps Ethernet LAN ports, as well as a Mini PCIe socket to support cellular modules. These versatile communication capabilities let users efficiently adapt the UC-8100A-ME-T to a variety of complex communications solutions.
UC-8100A-ME-T Series Hardware Introduction Model Descriptions The UC-8100A-ME-T Series includes the following models: • UC-8112A-ME-T-LX: Industrial computing platform with 2 serial ports, 2 Ethernet ports, SD socket, -40 to 85°C operating temperature range • UC-8112A-ME-T-LX-US: Industrial computing platform with 2 serial ports, 2 Ethernet ports, SD socket, US region LTE built-in,-40 to 70°C operating temperature range • UC-8112A-ME-T-LX-EU: Industrial computing platform with 2 serial ports, 2 Ether
UC-8100A-ME-T Series Hardware Introduction Hardware Specifications Computer CPU: Armv7 Cortex-A8 1 GHz OS (preinstalled): Moxa Industrial Linux (Based on Debian 9, Linux Kernel 4.4) USB: USB 2.0 host x 1 (type A connector) DRAM: 1 GB DDR3 SDRAM Storage Storage Expansion:• SDHC/SDXC socket for storage expansion • 8 GB eMMC flash with OS preinstalled Ethernet Interface LAN: 2 auto-sensing 10/100 Mbps ports (RJ45) Magnetic Isolation Protection: 1.
UC-8100A-ME-T Series Hardware Introduction Environmental Limits Operating Temperature: Without LTE Module preinstalled: -40 to 85°C (-40 to 185°F) With LTE Module preinstalled: -40 to 70°C (-40 to 158°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing) Anti-Vibration: 2 Grms @ IEC 60068-2-64, random wave, 5-500 Hz, 1 hr per axis (without any USB devices attached) Anti-Shock: 20 g @ IEC 60068-2-27, half sine wave, 30 ms Power Requirements Input Voltage:
2 Hardware Introduction The UC-8100A-ME-T embedded computers are compact and rugged, making them suitable for industrial applications. The LED indicators allow you to monitor performance and identify trouble spots quickly, and the multiple ports can be used to connect a variety of devices. The UC-8100A-ME-T Series comes with a reliable and stable hardware platform that lets you devote the bulk of your time to application development.
UC-8100A-ME-T Series Hardware Hardware Introduction Appearance Top View Front View 2-2
UC-8100A-ME-T Series Hardware Hardware Introduction Bottom View Dimension Unit: mm (in) 3-2
UC-8100A-ME-T Series Hardware Hardware Introduction LED Indicators The function of each LED is described in the table below: LED Name Color USB SD Power LAN1/ LAN 2 (RJ45 connector) Steady On USB device is connected and working normally. Off USB device is not connected. Steady On SD Card inserted and working normally. Green Off SD card is not detected. Green Power is on and the computer is working normally. Green Power is off.
UC-8100A-ME-T Series Hardware Hardware Introduction Real Time Clock The UC-8100A-ME-T’s real time clock is powered by a non-chargeable battery. We strongly recommend that you do not replace the lithium battery without help from a qualified Moxa support engineer. If you need to change the battery, contact the Moxa RMA service team. WARNING There is a risk of explosion if the battery is replaced with an incorrect type.
UC-8100A-ME-T Series Hardware Hardware Introduction Optional Wall Mounting The UC-8100A-ME-T can be mounted with an optional wall-mounting kit. Follow these steps: Step 1 Step 2 Use four screws to fasten the wall-mounting Use another four screws to mount the computer on brackets on the left panel of the computer. a wall or a cabinet. The optional wall-mounting kit should be purchased separately.
3 Hardware Connection Description In this chapter, we describe how to connect the UC-8100A-ME-T to a network and various devices for first time testing purposes.
UC-8100A-ME-T Series Hardware Hardware Connection Description Wiring Requirements In this section, we describe how to connect various devices to the embedded computer. Be sure to read and follow these common safety precautions before proceeding with the installation of any electronic device: • Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.
UC-8100A-ME-T Series Hardware Hardware Connection Description Connecting to the Network The Ethernet ports are located on the front panel of the UC-8100A-ME-T computers. The pin assignments for the Ethernet port are shown in the following figure. If you are using your own cable, make sure that the pin assignments on the Ethernet cable connector match the pin assignments on the Ethernet port.
UC-8100A-ME-T Series Hardware Hardware Connection Description Connecting to the Console Port The console port is an RS-232 port that can be connected to with a 4-pin pin header cable. You can use this port for debugging or firmware upgrade. Note that the cable is not included in the package. Pin Signal 1 TxD 2 RxD 3 NC 4 GND Connecting the Antennas There are three antenna connectors on the front panel of the UC-8100A-ME-T.
A Regulatory Approval Statements This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Class A: FCC Warning! This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
Federal Communications Commission (FCC) Statement 15.21 You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment. FCC RF Radiation Exposure Statement: 1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
Taiwan NCC Support FDD LTE 850/900/1900/2100 MHz 減少電磁波影響,請妥適使用 『注意:行動電話業務(2G)於106年6月停止提供服務後,本設備2G功能在國內將無法使用。』