DS9208-1D DIGITAL SCANNER PRODUCT REFERENCE GUIDE
DS9208-1D PRODUCT REFERENCE GUIDE 72E-162626-01 Revision A May 2012
ii DS9208-1D Product Reference Guide © 2012 Motorola Solutions, Inc. All rights reserved. No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from Motorola. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice. The software is provided strictly on an “as is” basis.
iii Revision History Changes to the original guide are listed below: Change -01 Rev A Date 5/2012 Description Initial release
iv DS9208-1D Product Reference Guide
TABLE OF CONTENTS About This Guide Introduction ..................................................................................................................................... Configurations................................................................................................................................. Chapter Descriptions ...................................................................................................................... Notational Conventions........................
vi DS9208-1D Product Reference Guide Integrated Electronic Article Surveillance (EAS) ............................................................................ Deactivation Antenna for Checkpoint EAS Systems ................................................................ EAS Deactivation Range ......................................................................................................... DS9208 Host Interface Cables and EAS ....................................................................
Table of Contents Scan Data Transmission Format ............................................................................................. 4-28 FN1 Substitution Values .......................................................................................................... 4-29 Transmit “No Read” Message .................................................................................................. 4-30 Chapter 5: USB Interface Introduction ...........................................................
viii DS9208-1D Product Reference Guide Chapter 7: IBM 468X / 469X Interface Introduction .................................................................................................................................... Connecting to an IBM 468X/469X Host ......................................................................................... IBM Parameter Defaults ................................................................................................................
Table of Contents Transmit UPC-E1 Check Digit ................................................................................................. UPC-A Preamble ..................................................................................................................... UPC-E Preamble ..................................................................................................................... UPC-E1 Preamble .....................................................................................
x DS9208-1D Product Reference Guide MSI ................................................................................................................................................ Enable/Disable MSI ................................................................................................................. Set Lengths for MSI ................................................................................................................. MSI Check Digits .........................................
Table of Contents Appendix C: Sample Bar Codes Code 39 ......................................................................................................................................... UPC/EAN ....................................................................................................................................... UPC-A, 100% ........................................................................................................................... EAN-13, 100% .........................
xii DS9208-1D Product Reference Guide
ABOUT THIS GUIDE Introduction The DS9208-1D Product Reference Guide provides general instructions for setting up, operating, maintaining, and troubleshooting the DS9208-1D digital scanner.
xiv DS9208-1D Product Reference Guide Chapter Descriptions Topics covered in this guide are as follows: • Chapter 1, Getting Started provides a product overview, unpacking instructions, cable connection, and mounting information. • Chapter 2, Data Capture describes parts of the digital scanner, beeper and LED definitions, and how to use the scanner in hand-held and hands-free (presentation) modes.
About This Guide xv Notational Conventions The following conventions are used in this document: • Italics are used to highlight the following: • Chapters and sections in this and related documents • Dialog box, window and screen names • Drop-down list and list box names • Check box and radio button names • Bold text is used to highlight the following: • Key names on a keypad • Button names on a screen.
xvi DS9208-1D Product Reference Guide Service Information If you have a problem using the equipment, contact your facility's technical or systems support. If there is a problem with the equipment, they will contact the Motorola Solutions Global Customer Support Center at: http://www.motorolasolutions.com/support.
CHAPTER 1 GETTING STARTED Introduction The DS9208-1D combines superior 1D omnidirectional bar code scanning and advanced feature set in a compact design. The digital scanner’s built-in stand seamlessly accommodates both counter-top and hand-held use. Whether in presentation or trigger mode, the digital scanner ensures comfort and ease of use for extended periods of time.
1-2 DS9208-1D Product Reference Guide Interfaces The DS9208-1D digital scanner supports: • USB connection to a host. The digital scanner autodetects a USB host and defaults to the HID keyboard interface type. Select other USB interface types by scanning programming bar code menus.This interface supports the following international keyboards (for Windows® environment): North America, German, French, French Canadian, Spanish, Italian, Swedish, UK English, Portuguese-Brazilian, and Japanese.
Getting Started 1-3 Setting Up the Digital Scanner Installing the Interface Cable 1. Insert the interface cable modular connector into the interface cable port on the rear of the digital scanner until you hear a click. The green LED lights and low/medium/high beeps sound, indicating that the scanner is operational. Cable interface port Interface cable modular connector To host Figure 1-2 Installing the Cable NOTE Different hosts require different cables.
1-4 DS9208-1D Product Reference Guide Configuring the Digital Scanner To configure the digital scanner use the bar codes included in this manual, or use the 123Scan2 configuration program. See Chapter 4, User Preferences & Miscellaneous Options and Chapter 9, Symbologies for information about programming the digital scanner using bar code menus. See Chapter 10, 123Scan2 for information on using this configuration program. Also see each host-specific chapter to set up connection to a specific host type.
Getting Started 3. 1-5 Slide the base of the digital scanner into the bracket, oriented so the scan window faces down. Figure 1-4 Inserting the DS9208-1D into the Wall Mount Bracket Locking Mount Bracket An optional locking mount bracket is available for "locking" the scanner into position on a horizontal (or vertical) surface. This option is recommended for applications where it is desirable to affix the scanner to a counter or desktop.
1-6 DS9208-1D Product Reference Guide 2. Tighten the screws to secure the bracket to the counter or desktop. 3. To insert the scanner into the Locking Mount Bracket, place the scanner onto the bracket and turn it 1/4 revolution clockwise until you hear a click and the scanner faces its final position. Figure 1-6 Inserting the DS9208-1D into the Locking Mount Bracket 4.
Getting Started 1-7 Accessories Required Accessories The digital scanner ships with the DS9208 Quick Start Guide. Also order an interface cable for the appropriate interface, and a universal power supply if the interface requires this. For additional items, contact a local Motorola representative or business partner.
1-8 DS9208-1D Product Reference Guide Mounting Templates Use the following templates to facilitate the proper placement of brackets and screws.
CHAPTER 2 DATA CAPTURE Introduction This chapter provides beeper and LED definitions, techniques involved in capturing bar codes, general instructions and tips about scanning, and decode range information.
2-2 DS9208-1D Product Reference Guide Beeper Definitions The digital scanner issues different beep sequences and patterns to indicate status. Table 2-1 defines beep sequences that occur during both normal scanning and while programming the digital scanner. Table 2-1 Beeper Definitions Beeper Sequence Indication Standard Use Low/medium/high beeps Power up. Short beep (tone programmable) A bar code symbol was decoded (if decode beeper is enabled). 4 low beeps Transmission error.
Data Capture 2-3 Table 2-1 Beeper Definitions (Continued) Beeper Sequence Indication Code 39 Buffering High/low beeps New Code 39 data was entered into the buffer. 3 long high beeps Code 39 buffer is full. High/low/high beeps The Code 39 buffer was erased. Low/high/low beeps The Code 39 buffer was erased or there was an attempt to clear or transmit an empty buffer. Low/high beeps A successful transmission of buffered data.
2-4 DS9208-1D Product Reference Guide Selecting Beeper Volume using Trigger The digital scanner emits a short beep when it successfully reads a bar code. To change the volume of the beep either scan the appropriate bar code in Beeper Volume on page 4-7, or use the trigger as follows: 1. Press and hold the trigger for an extended period of time (5 seconds by default - see Volume Adjustment Trigger Timeout on page 4-8 to change this).
Data Capture 2-5 Table 2-2 Standard LED Definitions LED Red Indication Out of rule memory. Erase some existing rules, then try to save rule again. Entry error, wrong bar code scanned, or criteria/action list is too long for a rule. Re-enter criterion or action. Firmware update Red, alternating between solid and fast blinking Firmware download is completing. Wait for this indicator to complete before using the scanner. This indicator is followed by a low/medium/high power up beep.
2-6 DS9208-1D Product Reference Guide To scan in hand-held presentation mode, pick up the digital scanner. It remains in presentation mode and decodes bar codes that are in its field of view. Figure 2-3 Scanning in Presentation Mode, Hand-Held Momentary Trigger Mode Scanning To operate the digital scanner in trigger mode: 1. Pick up the digital scanner. Press and release the trigger. The aiming dot displays. Figure 2-4 Scanning in Momentary Trigger Mode 2.
Data Capture 2-7 After a programmable time period (see Momentary Trigger Mode Timeout on page 4-16), the aiming dot turns off and the digital scanner returns to presentation mode, ready to read bar codes without use of the trigger. For beeper definitions, see Table 2-1. Aiming in Momentary Trigger Mode When scanning, the digital scanner projects a red aiming dot which allows positioning the bar code within its field of view.
2-8 DS9208-1D Product Reference Guide Decode Ranges Table 2-3 Decode Ranges Typical Working Ranges Symbol Density Bar Code Type Near Far 5.0 mil Code 39 0 in / 0 cm 4.5 in / 11.4 cm 10 mil 80% UPCEAN 0 in / 0 cm 8.5 in / 21.6 cm 13 mil 100% UPC 0 in / 0 cm 10.5 in / 26.
CHAPTER 3 MAINTENANCE & TECHNICAL SPECIFICATIONS Introduction This chapter provides suggested digital scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts). Maintenance Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy. • Do not allow abrasive material to touch the window. • Remove any dirt particles with a damp cloth.
3-2 DS9208-1D Product Reference Guide Troubleshooting Table 3-1 Troubleshooting Problem The aiming dot does not appear when pressing the trigger. Possible Causes Possible Solutions No power to the digital scanner. If the configuration requires a power supply, re-connect the power supply. Incorrect host interface cable is used. Connect the correct host interface cable. Interface/power cables are loose. Re-connect cables. Digital scanner is disabled.
Maintenance & Technical Specifications 3-3 Table 3-1 Troubleshooting (Continued) Problem Digital scanner decodes bar code, but does not transmit the data to the host. Host displays scanned data incorrectly. Possible Causes Possible Solutions Digital scanner is not programmed for the correct host type. Scan the appropriate host type programming bar code. See the chapter corresponding to the host type. Interface cable is loose. Re-connect the cable.
3-4 DS9208-1D Product Reference Guide Table 3-1 Troubleshooting (Continued) Problem Possible Causes Possible Solutions Digital scanner emits low/high/low beeps. Clearing Code 39 buffer. Normal when scanning the Code 39 Buffering Clear Buffer bar code or upon attempt to transmit an empty Code 39 buffer. Digital scanner emits a power-up beep after changing USB host type. The USB bus re-established power to the digital scanner. Normal when changing USB host type.
Maintenance & Technical Specifications 3-5 Technical Specifications Table 3-2 Technical Specifications Item Description Physical Characteristics Dimensions 5.512 in H x 3.232 in W x 3.150 in D 14.0 cm H x 8.21 cm W x 8.0 cm D Weight 9.5 oz (269.3 g) Voltage and Current Idle: 5 +/-10% VDC @ 150 ma average Scanning: 5 +/-10% VDC @ 230 ma average Performance Characteristics Light Source Aiming dot: 625 nm LED Illumination: 630 nm LEDs Imager Field of View (Horizontal x Vertical) 46º H x 29.
3-6 DS9208-1D Product Reference Guide Table 3-2 Technical Specifications (Continued) Item Ambient Light Immunity Description Immune to natural and artificial ambient light (i.e.
Maintenance & Technical Specifications Digital Scanner Signal Descriptions Pin 10 Pin 1 Interface cable modular connector Figure 3-1 Digital Scanner Cable Pinouts The signal descriptions in Table 3-3 apply to the connectors on the DS9208 digital scanner and are for reference only.
3-8 DS9208-1D Product Reference Guide
CHAPTER 4 USER PREFERENCES & MISCELLANEOUS OPTIONS Introduction You can program the digital scanner to perform various functions, or activate different features. This chapter describes each user preference feature and provides programming bar codes for selecting these features. The digital scanner ships with the settings shown in Table 4-1 on page 4-2 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults).
4-2 DS9208-1D Product Reference Guide Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high, scan the High Frequency (beeper tone) bar code listed under Beeper Tone on page 4-6. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Serial Response Timeout or Data Transmission Formats, require scanning several bar codes.
User Preferences & Miscellaneous Options Table 4-1 User Preferences Parameter Defaults (Continued) Parameter Parameter Number Default Page Number Decoding Illumination (Hand-Held Mode Only) F0h, 2Ah Enable 4-18 Post Decode Illumination F2h 29h Always Off 4-18 Illumination Always On (Presentation Mode Only) F2h 59h Illumination Automatically Controlled 4-19 Presentation Mode Field of View F1h 61h Full 4-20 Picklist Mode F0h 92h Enabled in Trigger Mode 4-21 Continuous Bar Code Read
4-4 DS9208-1D Product Reference Guide User Preferences Set Default Parameter You can reset the digital scanner to two types of defaults: factory defaults or custom defaults. Scan the appropriate bar code below to reset the digital scanner to its default settings and/or set its current settings as custom defaults. • Set Defaults - Scan this bar code to reset all default parameters as follows.
User Preferences & Miscellaneous Options 4-5 Parameter Bar Code Scanning Parameter # ECh To disable the decoding of parameter bar codes, including the Set Defaults parameter bar codes, scan the Disable Parameter Scanning bar code below. To enable decoding of parameter bar codes, scan Enable Parameter Scanning.
4-6 DS9208-1D Product Reference Guide Beeper Tone Parameter # 91h To select a decode beep frequency (tone), scan one of the following bar codes.
User Preferences & Miscellaneous Options Beeper Volume Parameter # 8Ch To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code.
4-8 DS9208-1D Product Reference Guide Volume Adjustment Trigger Timeout Parameter # F0h 93h Use this parameter to set the length of time needed to hold the trigger to adjust the volume. The scanner changes volume and beeps with the new volume.
User Preferences & Miscellaneous Options Beeper Duration Parameter # F1h 74h To select the duration for the beeper, scan one of the following bar codes. Short (00h) * Medium (01h) Long (02h) Suppress Power-up Beeps Parameter # F1h D1h Select whether or not to suppress the digital scanner’s power-up beeps.
4 - 10 DS9208-1D Product Reference Guide Low Power Mode Parameter # 80h This parameter determines whether or not the digital scanner enters low power mode after a decode attempt. If disabled, power remains on after each decode attempt.
User Preferences & Miscellaneous Options 4 - 11 Time Delay to Low Power Mode Parameter # 92h NOTE This parameter only applies when Low Power Mode is enabled. This parameter sets the time the digital scanner remains active before entering low power mode. The digital scanner wakes upon trigger pull or when the host attempts to communicate with the digital scanner.
4 - 12 DS9208-1D Product Reference Guide Time Delay to Low Power Mode (continued) 30 Minutes (2Dh) 45 Minutes (2Eh) *1 Hour (31h) 3 Hours (33h) 6 Hours (36h) 9 Hours (39h)
User Preferences & Miscellaneous Options 4 - 13 Trigger Mode Parameter # 8Ah Select one of the following trigger modes for the digital scanner: • Standard (Level) - A trigger pull activates decode processing. Decode processing continues until the bar code decodes, you release the trigger, or the Decode Session Timeout occurs. • Presentation - The digital scanner activates decode processing when it detects a bar code in its field of view.
4 - 14 DS9208-1D Product Reference Guide Trigger Aiming Pattern Parameter # F0h, 32h Select Enable Trigger Aiming Pattern to project the aiming pattern during bar code capture in trigger mode, or Disable Trigger Aiming Pattern to turn the aiming pattern off. NOTE With Picklist Mode on page 4-21 enabled, the decode aiming pattern flashes even when the Decode Aiming Pattern is disabled.
User Preferences & Miscellaneous Options 4 - 15 Presentation Aiming Pattern Parameter # F1h, 4Eh Select Enable Presentation Aiming Pattern to project the aiming pattern during bar code capture in presentation mode or Disable Presentation Aiming Pattern to turn the aiming pattern off. NOTE With Picklist Mode on page 4-21 enabled, the decode aiming pattern flashes even when the Decode Aiming Pattern is disabled.
4 - 16 DS9208-1D Product Reference Guide Momentary Trigger Mode Timeout Parameter # EDh In momentary trigger mode, the aiming dot appears upon pressing the trigger. Once in this mode, upon each trigger press the scanner attempts to decode the bar code in front of it. After a period of inactivity while the trigger is not pressed, the scanner reverts to presentation mode where there is no illumination until an item is presented.
User Preferences & Miscellaneous Options 4 - 17 Motion Detect Range Parameter # F2h 3Bh This parameter controls the distance, or range, at which the scanner detects object motion and then triggers while in Presentation Mode.
4 - 18 DS9208-1D Product Reference Guide Decoding Illumination (Hand-Held Mode Only) Parameter # F0h, 2Ah When in hand-held mode, selecting Enable Decoding Illumination causes the digital scanner to flash illumination to aid decoding. Select Disable Decoding Illumination to prevent the digital scanner from using decoding illumination. Enabling illumination usually results in superior images. The effectiveness of the illumination decreases as the distance to the target increases.
User Preferences & Miscellaneous Options 4 - 19 Illumination Always On (Presentation Mode Only) Parameter # F2h 59h Select Illumination Always On to keep the illumination LEDs on all the time. NOTE If you select Illumination Always On and the Post Decode Illumination is disabled, Illumination Always On takes precedence.
4 - 20 DS9208-1D Product Reference Guide Presentation Mode Field of View Parameter # F1h 61h In presentation mode, by default the digital scanner searches the larger area of the aiming pattern (Full Field of View). To search for a bar code in a smaller region around the aiming pattern’s center cross in order to speed search time, select Small Field of View or Medium Field of View.
User Preferences & Miscellaneous Options 4 - 21 Picklist Mode Parameter # F0h 92h Picklist mode enables the digital scanner to decode only the bar code targeted by the aiming dot. Select one of the following picklist modes for the digital scanner: • Disabled - Picklist mode is always disabled. • Enabled in Trigger Mode - Picklist mode is enabled when the digital scanner is out of trigger mode and disabled when the digital scanner is in presentation mode.
4 - 22 DS9208-1D Product Reference Guide Continuous Bar Code Read Parameter # F1h 89h Enable this to report every bar code while the trigger is pressed. NOTE Motorola strongly recommends enabling Picklist Mode with this feature. Disabling Picklist Mode can cause accidental decodes when more than one bar code is in the imaging engine's field of view.
User Preferences & Miscellaneous Options 4 - 23 Decode Session Timeout Parameter # 88h This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds. To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired on time. Enter a leading zero for single digit numbers.
4 - 24 DS9208-1D Product Reference Guide Timeout Between Decodes, Different Symbols Parameter # 90h Use this option in presentation mode and Continuous Bar Code Read to control the time the scanner is inactive between decoding different symbols. It is programmable in 0.1 second increments from 0.1 to 9.9 seconds. The default is 0.2 seconds.
User Preferences & Miscellaneous Options 4 - 25 Motion Tolerance (Hand-Held Trigger Modes Only) Parameter # F2h 5Ah Less Motion Tolerance provides optimal decoding performance on 1D bar codes. To increase motion tolerance and speed decoding when scanning a series of 1D bar codes in rapid progression, scan More Motion Tolerance.
4 - 26 DS9208-1D Product Reference Guide Miscellaneous Scanner Parameters Transmit Code ID Character Parameter # 2Dh A Code ID character identifies the code type of a scanned bar code. This is useful when decoding more than one code type. In addition to any single character prefix already selected, the Code ID character is inserted between the prefix and the decoded symbol. Select no Code ID character, a Symbol Code ID character, or an AIM Code ID character.
User Preferences & Miscellaneous Options 4 - 27 Prefix/Suffix Values Key Category Parameter # P = 63h, S1 = 62h, S2 = 64h Decimal Value Parameter # P = 69h, S1 = 68h, S2 = 6Ah You can append a prefix and/or one or two suffixes to scan data for use in data editing. To set a value for a prefix or suffix, scan a four-digit number (i.e., four bar codes from Appendix D, Numeric Bar Codes) that corresponds to that value. See Table E-1 on page E-1 for the four-digit codes.
4 - 28 DS9208-1D Product Reference Guide Scan Data Transmission Format Parameter # EBh To set the scan data format, scan one of the following bar codes. NOTE If using this parameter do not use ADF rules to set the prefix/suffix. To set values for the prefix and/or suffix, see Prefix/Suffix Values on page 4-27.
User Preferences & Miscellaneous Options 4 - 29 Scan Data Transmission Format (continued) (05h) (06h) (07h) FN1 Substitution Values Key Category Parameter # 67h Decimal Value Parameter # 6Dh The wedge and USB HID keyboard hosts support a FN1 Substitution feature. Enabling this substitutes any FN1 character (0x1b) in an EAN128 bar code with a value. This value defaults to 7013 (Enter key).
4 - 30 DS9208-1D Product Reference Guide Transmit “No Read” Message Parameter # 5Eh Scan a bar code below to select whether or not to transmit a No Read message. Enable this to transmit the characters NR when a successful decode does not occur before trigger release or the Decode Session Timeout expires. See Decode Session Timeout on page 4-23. Disable this to send nothing to the host if a symbol does not decode.
CHAPTER 5 USB INTERFACE Introduction This chapter describes how to set up the digital scanner with a USB host. The digital scanner connects directly to a USB host, or a powered USB hub, which powers it. No additional power supply is required. Throughout the programming bar code menus, asterisks (*) indicate default values. *Indicates Default NOTE *North American Standard USB Keyboard Feature/Option Most computer monitors allow scanning the bar codes directly on the screen.
5-2 DS9208-1D Product Reference Guide Connecting a USB Interface Interface Cable USB Connector Figure 5-1 USB Connection The digital scanner connects with USB-capable hosts including: • Desktop PCs and notebooks • Apple™ iMac, G4, iBooks (North America only) • IBM SurePOS terminals • Sun, IBM, and other network computers that support more than one keyboard. The following operating systems support the digital scanner through USB: • Windows® 98, 2000, ME, XP • MacOS 8.5 and higher • IBM 4690 OS.
USB Interface 5-3 4. On first installation when using Windows, the software prompts to select or install the Human Interface Device driver. To install this driver, provided by Windows, click Next through all the choices and click Finished on the last choice. The digital scanner powers up during this installation. 5. To modify any other parameter options, scan the appropriate bar codes in this chapter. If problems occur with the system, see Troubleshooting on page 3-2.
5-4 DS9208-1D Product Reference Guide USB Host Parameters USB Device Type Select the desired USB device type. NOTE NOTE When changing USB Device Types, the digital scanner automatically resets and issues the standard startup beep sequences. Before selecting USB CDC Host, install the CDC INF file on the host to ensure the scanner does not stall during power up (due to a failure to enumerate USB).
USB Interface USB Device Type (continued) Simple COM Port Emulation USB CDC Host Symbol Native API (SNAPI) Symbol Native API (SNAPI) Status Handshaking After selecting a SNAPI interface as the USB device type, select whether to enable or disable status handshaking.
5-6 DS9208-1D Product Reference Guide USB Country Keyboard Types - Country Codes Scan the bar code corresponding to the keyboard type. This setting applies only to the USB HID Keyboard Emulation device. NOTE When changing USB country keyboard types the digital scanner automatically resets and issues the standard startup beep sequences.
USB Interface USB Country Keyboard Types - Country Codes (continued) French Belgian Windows Spanish Windows Italian Windows Swedish Windows UK English Windows Japanese Windows (ASCII) Portuguese-Brazilian Windows 5-7
5-8 DS9208-1D Product Reference Guide USB Keystroke Delay This parameter sets the delay, in milliseconds, between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data.
USB Interface 5-9 Simulated Caps Lock Enable this to invert upper and lower case characters on the bar code as if the Caps Lock state is enabled on the keyboard. This inversion occurs regardless of the keyboard’s Caps Lock state. Note that this only applies to alpha characters. *Disable Simulated Caps Lock Enable Simulated Caps Lock USB CAPS Lock Override This option applies only to the HID Keyboard Emulation device.
5 - 10 DS9208-1D Product Reference Guide USB Ignore Unknown Characters This option applies only to the HID Keyboard Emulation device and IBM device. Unknown characters are characters the host does not recognize. Select Send Bar Codes With Unknown Characters to send all bar code data except for unknown characters. The digital scanner issues no error beeps.
USB Interface 5 - 11 USB Ignore Beep Directive This applies only to IBM hand-held, IBM tabletop, and OPOS devices. Scan one of the following bar codes to honor or ignore a beep directive. All directives are still acknowledged as if they were processed. *Honor USB Beep Directive Ignore USB Beep Directive USB Ignore Type Directive This applies only to IBM hand-held, IBM tabletop, and OPOS devices. Scan one of the following bar codes to honor or ignore a code type enable/disable directive.
5 - 12 DS9208-1D Product Reference Guide Emulate Keypad Enable this to send all characters as ASCII sequences over the numeric keypad. For example ASCII A transmits as “ALT make” 0 6 5 “ALT Break”. *Disable Keypad Emulation Enable Keypad Emulation Emulate Keypad with Leading Zero Enable this to send character sequences sent over the numeric keypad as ISO characters which have a leading zero. For example ASCII A transmits as “ALT MAKE” 0 0 6 5 “ALT BREAK”.
USB Interface 5 - 13 USB Keyboard FN 1 Substitution This option applies only to the USB HID Keyboard Emulation device. Enable this to replace any FN 1 characters in an EAN 128 bar code with a user-selected Key Category and value (see FN1 Substitution Values on page 4-29 to set the Key Category and Key Value). Enable *Disable Function Key Mapping ASCII values under 32 are normally sent as a control-key sequences (see Table 5-2 on page 5-19).
5 - 14 DS9208-1D Product Reference Guide Convert Case Enable this to convert all bar code data to the selected case. *No Case Conversion Convert All to Upper Case Convert All to Lower Case USB Static CDC When disabled, each device connected consumes another COM port (first device = COM1, second device = COM2, third device = COM3, etc.) When enabled, each device connects to the same COM port.
USB Interface 5 - 15 USB Transmission Speed Parameters Use the following parameters to speed USB data transmission: • USB Polling Interval - When using more current USB systems, use this parameter to set a lower interval in order to increase data transmission speed. • Fast HID Keyboard - When configured as a USB HID keyboard device, use this parameter to increase the data transmission speed of printable (7-bit) ASCII characters.
5 - 16 DS9208-1D Product Reference Guide USB Polling Interval (continued) 3 msec 4 msec 5 msec 6 msec 7 msec *8 msec 9 msec
USB Interface 5 - 17 Fast HID Keyboard This option transmits USB HID keyboard data at a faster rate. NOTE Enabling Emulate Keypad on page 5-12 or Quick Keypad Emulation overrides Fast HID Keyboard. Enable *Disable Quick Keypad Emulation This option applies only to the HID keyboard emulation device when Emulate Keypad on page 5-12 is enabled. This parameter enables a quicker method of emulation utilizing the numeric keypad. The default value is Disable.
5 - 18 DS9208-1D Product Reference Guide IBM Specification Version The IBM USB interface specification version selected defines how code types are reported over the IBM USB interface. *Original Specification Version 2.
USB Interface 5 - 19 ASCII Character Set for USB Table 5-2 USB Prefix/Suffix Values Full ASCII Code 39 Encode Char.
5 - 20 DS9208-1D Product Reference Guide Table 5-2 USB Prefix/Suffix Values (Continued) Full ASCII Code 39 Encode Char.acter Prefix/ Suffix Value Keystroke 1026 $Z CTRL Z 1027 %A CTRL [/ESC1 1028 %B CTRL \ 1029 %C CTRL ] 1030 %D CTRL 6 1031 %E CTRL - 1032 Space Space 1033 /A ! 1034 /B “ 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . .
USB Interface 5 - 21 Table 5-2 USB Prefix/Suffix Values (Continued) Full ASCII Code 39 Encode Char.
5 - 22 DS9208-1D Product Reference Guide Table 5-2 USB Prefix/Suffix Values (Continued) Full ASCII Code 39 Encode Char.
USB Interface 5 - 23 Table 5-2 USB Prefix/Suffix Values (Continued) Full ASCII Code 39 Encode Char.acter Prefix/ Suffix Value Keystroke 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1117 +U u 1118 +V v 1119 +W w 1120 +X x 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q | 1125 %R } 1126 %S ~ 1The keystroke in bold transmits only if you enable Function Key Mapping on page 5-13. Otherwise, the unbolded keystroke transmits.
5 - 24 DS9208-1D Product Reference Guide Table 5-3 USB ALT Key Character Set ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z
USB Interface 5 - 25 Table 5-4 USB GUI Key Character Set GUI Key Keystroke 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P 3081 GUI Q Note: GUI Shift Keys - The Apple™ iMac keyboard has an ap
5 - 26 DS9208-1D Product Reference Guide Table 5-4 USB GUI Key Character Set (Continued) GUI Key Keystroke 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Note: GUI Shift Keys - The Apple™ iMac keyboard has an apple key on either side of the space bar. Windows-based systems have a GUI key to the left of the left ALT key, and to the right of the right ALT key.
USB Interface 5 - 27 Table 5-5 USB F Key Character Set F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 5018 F18 5019 F19 5020 F20 5021 F21 5022 F22 5023 F23 5024 F24
5 - 28 DS9208-1D Product Reference Guide Table 5-6 USB Numeric Keypad Character Set Numeric Keypad Keystroke 6042 * 6043 + 6044 undefined 6045 - 6046 .
USB Interface 5 - 29 Table 5-7 USB Extended Keypad Character Set Extended Keypad Keystroke 7001 Break 7002 Delete 7003 PgUp 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Down Arrow 7017 Left Arrow 7018 Right Arrow
5 - 30 DS9208-1D Product Reference Guide
CHAPTER 6 RS-232 INTERFACE Introduction This chapter describes how to set up the digital scanner with an RS-232 host. Use the RS-232 interface to connect the digital scanner to point-of-sale devices, host computers, or other devices with an available RS-232 port (e.g., com port). If your host does not appear in Table 6-2, refer to the documentation for the host device to set communication parameters to match the host.
6-2 DS9208-1D Product Reference Guide Connecting an RS-232 Interface Connect the digital scanner directly to the host computer. Interface Cable Serial Port Connector to Host Power Supply Cable Figure 6-1 RS-232 Direct Connection NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 6-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the digital scanner are the same. 1.
RS-232 Interface RS-232 Parameter Defaults Table 6-1 lists the defaults for RS-232 host parameters. To change any option, scan the appropriate bar code(s) provided in the RS-232 Host Parameters section beginning on page 6-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
6-4 DS9208-1D Product Reference Guide RS-232 Host Parameters Various RS-232 hosts use their own parameter default settings. Selecting standard, ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, Omron, or Common Use Terminal Equipment (CUTE-LP/LG bar code readers) sets the defaults listed in Table 6-2.
RS-232 Interface 6-5 RS-232 Host Parameters (continued) Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, Omron, or Common Use Terminal Equipment (CUTE-LP/LG bar code readers) enables the transmission of code ID characters listed in Table 6-3. These code ID characters are not programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature for these terminals.
6-6 DS9208-1D Product Reference Guide RS-232 Host Types To select an RS-232 host interface, scan one of the following bar codes. *Standard RS-2321 ICL RS-232 Wincor-Nixdorf RS-232 Mode A Wincor-Nixdorf RS-232 Mode B Olivetti ORS4500 Omron 1Scanning Standard RS-232 activates the RS-232 driver, but does not change port settings (e.g., parity, data bits, handshaking). Selecting another RS-232 host type bar code changes these settings.
RS-232 Interface 6-7 RS-232 Host Types (continued) OPOS/JPOS Fujitsu RS-232 CUTE 1 1The CUTE host disables all parameter scanning, including Set Defaults. If you inadvertently select CUTE, scan *Enable Parameter Bar Code Scanning (01h) on page 4-5, then change the host selection.
6-8 DS9208-1D Product Reference Guide Baud Rate Baud rate is the number of bits of data transmitted per second. Set the digital scanner's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form. NOTE The digital scanner does not support baud rates below 9600.
RS-232 Interface 6-9 Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. • Select Odd parity to set the parity bit value to 0 or 1, based on data, to ensure that the coded character contains an odd number of 1 bits. • Select Even parity to set the parity bit value is set to 0 or 1, based on data, to ensure that the coded character contains an even number of 1 bits.
6 - 10 DS9208-1D Product Reference Guide Stop Bits The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. Select the number of stop bits (one or two) based on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
RS-232 Interface 6 - 11 Check Receive Errors Select whether or not to check the parity, framing, and overrun of received characters. The parity value of received characters is verified against the parity parameter selected above. *Check For Received Errors Do Not Check For Received Errors Hardware Handshaking The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS).
6 - 12 DS9208-1D Product Reference Guide Hardware Handshaking (continued) • None: Scan this bar code to disable hardware handshaking. • Standard RTS/CTS: Scan this bar code to select Standard RTS/CTS Hardware Handshaking. • RTS/CTS Option 1: If you select RTS/CTS Option 1, the digital scanner asserts RTS before transmitting and ignores the state of CTS. The scanner de-asserts RTS when the transmission completes.
RS-232 Interface 6 - 13 Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options. If software handshaking and hardware handshaking are both enabled, hardware handshaking takes precedence. • None: Select this to transmit data immediately. The digital scanner expects no response from the host.
6 - 14 DS9208-1D Product Reference Guide Software Handshaking (continued) *None ACK/NAK ENQ ACK/NAK with ENQ XON/XOFF
RS-232 Interface 6 - 15 Host Serial Response Timeout This parameter specifies how long the digital scanner waits for an ACK, NAK, or CTS before determining that a transmission error occurred. This only applies when in one of the ACK/NAK software handshaking modes, or RTS/CTS hardware handshaking mode. *Minimum: 2 Sec Low: 2.5 Sec Medium: 5 Sec High: 7.5 Sec Maximum: 9.
6 - 16 DS9208-1D Product Reference Guide RTS Line State This parameter sets the idle state of the Serial Host RTS line. Scan a bar code below to select Low RTS or High RTS line state. *Host: Low RTS Host: High RTS Beep on If you enable this parameter, the digital scanner issues a beep when it detects a character on the RS-232 serial line. indicates an illegal entry or other important event.
RS-232 Interface 6 - 17 Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions.
6 - 18 DS9208-1D Product Reference Guide Nixdorf Beep/LED Options If you selected Nixdorf Mode B, this indicates when the digital scanner beeps and turns on its LED after a decode. *Normal Operation (Beep/LED immediately after decode) Beep/LED After Transmission Beep/LED After CTS Pulse Ignore Unknown Characters Unknown characters are characters the host does not recognize. Select Send Bar Codes with Unknown Characters to send all bar code data except for unknown characters.
RS-232 Interface 6 - 19 ASCII Character Set for RS-232 You can assign the values in Table 6-4 as prefixes or suffixes for ASCII character data transmission.
6 - 20 DS9208-1D Product Reference Guide Table 6-4 Prefix/Suffix Values (Continued) Prefix/Suffix Value Full ASCII Code 39 Encode Character ASCII Character 1028 %B FS 1029 %C GS 1030 %D RS 1031 %E US 1032 Space Space 1033 /A ! 1034 /B " 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . .
RS-232 Interface 6 - 21 Table 6-4 Prefix/Suffix Values (Continued) Prefix/Suffix Value Full ASCII Code 39 Encode Character ASCII Character 1059 %F ; 1060 %G < 1061 %H = 1062 %I > 1063 %J ? 1064 %V @ 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 10
6 - 22 DS9208-1D Product Reference Guide Table 6-4 Prefix/Suffix Values (Continued) Prefix/Suffix Value Full ASCII Code 39 Encode Character ASCII Character 1090 Z Z 1091 %K [ 1092 %L \ 1093 %M ] 1094 %N ^ 1095 %O _ 1096 %W ` 1097 +A a 1098 +B b 1099 +C c 1100 +D d 1101 +E e 1102 +F f 1103 +G g 1104 +H h 1105 +I i 1106 +J j 1107 +K k 1108 +L l 1109 +M m 1110 +N n 1111 +O o 1112 +P p 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1
RS-232 Interface 6 - 23 Table 6-4 Prefix/Suffix Values (Continued) Prefix/Suffix Value Full ASCII Code 39 Encode Character ASCII Character 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q | 1125 %R } 1126 %S ~ 1127 Undefined 7013 ENTER
6 - 24 DS9208-1D Product Reference Guide
CHAPTER 7 IBM 468X / 469X INTERFACE Introduction This chapter describes how to set up the digital scanner with an IBM 468X/469X host. Throughout the programming bar code menus, asterisks (*) indicate default values. * Indicates Default NOTE *Disable Convert to Code 39 Feature/Option Most computer monitors allow scanning the bar codes directly on the screen.
7-2 DS9208-1D Product Reference Guide Connecting to an IBM 468X/469X Host Connect the digital scanner directly to the host interface. Interface Cable Host Port Connector Figure 7-1 IBM Direct Connection NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 7-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the digital scanner are the same. 1.
IBM 468X / 469X Interface 7-3 IBM Parameter Defaults Table 7-1 lists the defaults for IBM host parameters. To change any option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 7-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
7-4 DS9208-1D Product Reference Guide IBM 468X/469X Host Parameters Port Address This parameter sets the IBM 468X/469X port used. NOTE Scanning one of these bar codes enables the RS-485 interface on the digital scanner.
IBM 468X / 469X Interface 7-5 Convert Unknown to Code 39 Scan a bar code below to enable or disable the conversion of unknown bar code type data to Code 39. Enable Convert Unknown to Code 39 *Disable Convert Unknown to Code 39 Ignore Beep Directive Scan one of the following bar codes to honor or ignore a beep directive made over the IBM RS-485 bus. All directives are still acknowledged to the IBM RS-485 host as if they were processed.
7-6 DS9208-1D Product Reference Guide Ignore Configuration Directive Scan one of the following bar codes to honor or ignore a code type enable/disable directive made over the IBM RS-485 bus. All directives are still acknowledged to the IBM RS-485 host as if they were processed.
CHAPTER 8 KEYBOARD WEDGE INTERFACE Introduction This chapter describes how to set up a Keyboard Wedge interface with the digital scanner. With this interface, the digital scanner is connected between the keyboard and host computer, and translates bar code data into keystrokes. The host computer accepts the keystrokes as if they originated from the keyboard. This mode adds bar code reading functionality to a system designed for manual keyboard input. Keyboard keystrokes are simply passed through.
8-2 DS9208-1D Product Reference Guide Connecting a Keyboard Wedge Interface Male DIN Connector Keyboard Connector Female DIN Connector Figure 8-1 Keyboard Wedge Connection with Y-cable To connect the Keyboard Wedge interface Y-cable: NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 8-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the digital scanner are the same. 1.
Keyboard Wedge Interface 8-3 Keyboard Wedge Parameter Defaults Table 8-1 lists the defaults for Keyboard Wedge host parameters. To change any option, scan the appropriate bar code(s) in the Keyboard Wedge Host Parameters section beginning on page 8-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
8-4 DS9208-1D Product Reference Guide Keyboard Wedge Host Parameters Keyboard Wedge Host Types Select the Keyboard Wedge host by scanning one of the bar codes below.
Keyboard Wedge Interface 8-5 Keyboard Wedge Country Types - Country Codes Scan the bar code corresponding to the keyboard type. If your keyboard type does not appear, see Alternate Numeric Keypad Emulation on page 8-8.
8-6 DS9208-1D Product Reference Guide Keyboard Wedge Country Types - Country Codes (continued) Spanish Windows Italian Windows Swedish Windows UK English Windows Japanese Windows Portuguese-Brazilian Windows
Keyboard Wedge Interface 8-7 Ignore Unknown Characters Unknown characters are characters the host does not recognize. Select Send Bar Codes With Unknown Characters to send all bar code data except for unknown characters. The digital scanner issues no error beeps. Select Do Not Send Bar Codes With Unknown Characters to send bar code data up to the first unknown character. The digital scanner issues an error beep.
8-8 DS9208-1D Product Reference Guide Intra-Keystroke Delay Enable this to insert an additional delay between each emulated key depression and release. This sets the Keystroke Delay parameter to a minimum of 5 msec as well. Enable *Disable Alternate Numeric Keypad Emulation This allows emulation of most other country keyboard types not listed in Keyboard Wedge Country Types Country Codes on page 8-5 in a Microsoft® operating system environment.
Keyboard Wedge Interface 8-9 Simulated Caps Lock Enable this to invert upper and lower case characters on the bar code as if the Caps Lock state is enabled on the keyboard. This inversion occurs regardless of the keyboard’s Caps Lock state. Note that this only applies to alpha characters. Enable Caps Lock On *Disable Caps Lock On Caps Lock Override Enable this on AT or AT Notebook hosts to preserve the case of the data regardless of the state of the Caps Lock key.
8 - 10 DS9208-1D Product Reference Guide Convert Wedge Data Enable this to convert all bar code data to the selected case. Convert to Upper Case Convert to Lower Case *No Convert Function Key Mapping ASCII values under 32 are normally sent as control key sequences (see Table 8-2 on page 8-13). Enable this parameter to send the keys in bold in place of the standard key mapping. Table entries that do not have a bold entry remain the same whether or not you enable this parameter.
Keyboard Wedge Interface 8 - 11 FN1 Substitution Enable this to replace FN1 characters in an EAN128 bar code with a user-selected keystroke (see FN1 Substitution on page 8-11). Enable *Disable Send Make and Break Enable this to prevent sending the scan codes for releasing a key. *Send Make and Break Scan Codes Send Make Scan Code Only NOTE Windows-based systems must use Send Make and Break Scan Codes.
8 - 12 DS9208-1D Product Reference Guide Keyboard Maps Refer to the following keyboard maps for prefix/suffix keystroke parameters. To program the prefix/suffix values, see the bar codes on page 4-27.
Keyboard Wedge Interface 8 - 13 ASCII Character Set for Keyboard Wedge NOTE Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, if you enable Code 39 Full ASCII and scan +B, it transmits as b, %J as ?, and %V as @. Scanning ABC%I outputs the keystroke equivalent of ABC >. Table 8-2 Keyboard Wedge ASCII Character Set Full ASCII Code 39 Encode Char.
8 - 14 DS9208-1D Product Reference Guide Table 8-2 Keyboard Wedge ASCII Character Set (Continued) Full ASCII Code 39 Encode Char.acter ASCII Value Keystroke 1024 $X CTRL X 1025 $Y CTRL Y 1026 $Z CTRL Z 1027 %A CTRL [ /ESC1 1028 %B CTRL \ 1029 %C CTRL ] 1030 %D CTRL 6 1031 %E CTRL - 1032 Space Space 1033 /A ! 1034 /B “ 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . .
Keyboard Wedge Interface 8 - 15 Table 8-2 Keyboard Wedge ASCII Character Set (Continued) Full ASCII Code 39 Encode Char.
8 - 16 DS9208-1D Product Reference Guide Table 8-2 Keyboard Wedge ASCII Character Set (Continued) Full ASCII Code 39 Encode Char.
Keyboard Wedge Interface 8 - 17 Table 8-2 Keyboard Wedge ASCII Character Set (Continued) ASCII Value Full ASCII Code 39 Encode Char.acter Keystroke 1111 +O o 1112 +P p 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1117 +U u 1118 +V v 1119 +W w 1120 +X x 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q | 1125 %R } 1126 %S ~ 1 The keystroke in bold transmits only if you enabled Function Key Mapping on page 8-10. Otherwise, the unbolded keystroke transmits.
8 - 18 DS9208-1D Product Reference Guide Table 8-3 Keyboard Wedge ALT Key Character Set (Continued) ALT Keys Keystroke 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z Table 8-4 Keyboard Wedge GUI Key Character Set GUI Keys Keystrokes 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GU
Keyboard Wedge Interface 8 - 19 Table 8-4 Keyboard Wedge GUI Key Character Set (Continued) GUI Keys Keystrokes 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P 3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Table 8-5 Keyboard Wedge F Key Character Set F Keys Keystroke 5001 F1 5002 F2 5003 F3 500
8 - 20 DS9208-1D Product Reference Guide Table 8-5 Keyboard Wedge F Key Character Set (Continued) F Keys Keystroke 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 5018 F18 5019 F19 5020 F20 5021 F21 5022 F22 5023 F23 5024 F24 Table 8-6 Keyboard Wedge Numeric Keypad Character Set Numeric Keypad Keystroke 6042 * 6043 + 6044 undefined 6045 - 6046 .
Keyboard Wedge Interface 8 - 21 Table 8-6 Keyboard Wedge Numeric Keypad Character Set (Continued) Numeric Keypad Keystroke 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock Table 8-7 Keyboard Wedge Extended Keypad Character Set Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Dn Arrow
8 - 22 DS9208-1D Product Reference Guide
CHAPTER 9 SYMBOLOGIES Introduction This chapter describes symbology features and provides programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner powers down. NOTE Most computer monitors allow scanning the bar codes directly on the screen.
9-2 DS9208-1D Product Reference Guide Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter. Symbology Parameter Defaults Table 9-1 lists the defaults for all symbologies parameters. To change the default values, scan the appropriate bar codes in this guide. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set Default Parameter on page 4-4.
Symbologies 9-3 Table 9-1 Parameter Defaults (Continued) Parameter Parameter Number Default Page Number Convert UPC-E to A 25h Disable 9-20 Convert UPC-E1 to A 26h Disable 9-20 EAN-8/JAN-8 Extend 27h Disable 9-21 UCC Coupon Extended Code 55h Disable 9-21 Coupon Report F1h DAh New Coupon Symbols 9-22 ISSN EAN F1h 69h Enable 9-23 Code 128 08h Enable 9-24 Set Length(s) for Code 128 D1h, D2h Any Length 9-24 GS1-128 (formerly UCC/EAN-128) 0Eh Enable 9-25 ISBT 128 54h
9-4 DS9208-1D Product Reference Guide Table 9-1 Parameter Defaults (Continued) Parameter Parameter Number Default Page Number Code 11 Code 11 0Ah Disable 9-38 Set Lengths for Code 11 1Ch, 1Dh Length Within Range: 4 to 55 9-38 Code 11 Check Digit Verification 34h Disable 9-40 Transmit Code 11 Check Digit(s) 2Fh Disable 9-41 Interleaved 2 of 5 (ITF) 06h Disable 9-41 Set Lengths for I 2 of 5 16h, 17h 1 Length; Length = 14 9-41 I 2 of 5 Check Digit Verification 31h Disable 9-44
Symbologies 9-5 Table 9-1 Parameter Defaults (Continued) Parameter Parameter Number Default Page Number Chinese 2 of 5 Chinese 2 of 5 F0h 98h Disable 9-55 Matrix 2 of 5 F1h 6Ah Disable 9-56 Matrix 2 of 5 Lengths F1h 6Bh F1h 6Ch Length; Length = 14 9-57 Matrix 2 of 5 Check Digit F1h 6Eh Disable 9-58 Transmit Matrix 2 of 5 Check Digit F1h 6Fh Disable 9-58 Korean 3 of 5 F1h 45h Disable 9-59 Inverse 1D F1h 4Ah Regular 9-60 GS1 DataBar (GS1 DataBar Omnidirectional, GS1 DataBar
9-6 DS9208-1D Product Reference Guide Disable All Code Types To disable all symbologies, scan the bar code below. This is useful when enabling only a few code types.
Symbologies UPC/EAN Enable/Disable UPC-A Parameter # 01h To enable or disable UPC-A, scan the appropriate bar code below. *Enable UPC-A (01h) Disable UPC-A (00h) Enable/Disable UPC-E Parameter # 02h To enable or disable UPC-E, scan the appropriate bar code below.
9-8 DS9208-1D Product Reference Guide Enable/Disable UPC-E1 Parameter # 0Ch UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. UPC-E1 is not a UCC (Uniform Code Council) approved symbology. NOTE Enable UPC-E1 (01h) *Disable UPC-E1 (00h) Enable/Disable EAN-8/JAN-8 Parameter # 04h To enable or disable EAN-8/JAN-8, scan the appropriate bar code below.
Symbologies 9-9 Enable/Disable EAN-13/JAN-13 Parameter # 03h To enable or disable EAN-13/JAN-13, scan the appropriate bar code below. *Enable EAN-13/JAN-13 (01h) Disable EAN-13/JAN-13 (00h) Enable/Disable Bookland EAN Parameter # 53h To enable or disable Bookland EAN, scan the appropriate bar code below. Enable Bookland EAN (01h) *Disable Bookland EAN (00h) NOTE If Bookland EAN is enabled, select a Bookland ISBN Format on page 9-10.
9 - 10 DS9208-1D Product Reference Guide Bookland ISBN Format Parameter # F1h 40h If Bookland EAN is enabled, select one of the following formats for Bookland data: • Bookland ISBN-10 - The digital scanner reports Bookland data starting with 978 in traditional 10-digit format with the special Bookland check digit for backward-compatibility. Data starting with 979 is not considered Bookland in this mode.
Symbologies 9 - 11 Decode UPC/EAN/JAN Supplementals Parameter # 10h Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). The following options are available: • If you select Ignore UPC/EAN with Supplementals, and the digital scanner is presented with a UPC/EAN plus supplemental symbol, the scanner decodes UPC/EAN and ignores the supplemental characters.
9 - 12 DS9208-1D Product Reference Guide Decode UPC/EAN/JAN Supplementals (continued) Decode UPC/EAN/JAN Only With Supplementals (01h) *Ignore Supplementals (00h) Autodiscriminate UPC/EAN/JAN Supplementals (02h) Enable 378/379 Supplemental Mode (04h) Enable 978/979 Supplemental Mode (05h) Enable 977 Supplemental Mode (07h)
Symbologies 9 - 13 Decode UPC/EAN/JAN Supplementals (continued) Enable 414/419/434/439 Supplemental Mode (06h) Enable 491 Supplemental Mode (08h) Enable Smart Supplemental Mode (03h) Supplemental User-Programmable Type 1 (09h) Supplemental User-Programmable Type 1 and 2 (0Ah) Smart Supplemental Plus User-Programmable 1 (0Bh) Smart Supplemental Plus User-Programmable 1 and 2 (0Ch)
9 - 14 DS9208-1D Product Reference Guide User-Programmable Supplementals Supplemental 1: Parameter # F1h 43h Supplemental 2: Parameter # F1h 44h If you selected a Supplemental User-Programmable option from Decode UPC/EAN/JAN Supplementals on page 9-11, select User-Programmable Supplemental 1 to set the 3-digit prefix. Then select the 3 digits using the numeric bar codes beginning on page D-1. Select User-Programmable Supplemental 2 to set a second 3-digit prefix.
Symbologies 9 - 15 UPC/EAN/JAN Supplemental AIM ID Format Parameter # F1h A0h Select an output format when reporting UPC/EAN/JAN bar codes with Supplementals with Transmit Code ID Character on page 4-26 set to AIM Code ID Character: • Separate - transmit UPC/EAN with supplementals with separate AIM IDs but one transmission, i.e.: ]E<0 or 4>]E<1 or 2>[supplemental data] • Combined – transmit UPC/EAN with supplementals with one AIM ID and one transmission, i.e.
9 - 16 DS9208-1D Product Reference Guide Transmit UPC-A Check Digit Parameter # 28h The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-A check digit. It is always verified to guarantee the integrity of the data.
Symbologies 9 - 17 Transmit UPC-E1 Check Digit Parameter # 2Ah The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E1 check digit. It is always verified to guarantee the integrity of the data.
9 - 18 DS9208-1D Product Reference Guide UPC-E Preamble Parameter # 23h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.
Symbologies 9 - 19 UPC-E1 Preamble Parameter # 24h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E1 preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.
9 - 20 DS9208-1D Product Reference Guide Convert UPC-E to UPC-A Parameter # 25h Enable this to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). Disable this to transmit UPC-E decoded data as UPC-E data, without conversion.
Symbologies 9 - 21 EAN-8/JAN-8 Extend Parameter # 27h Enable this parameter to add five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. Disable this to transmit EAN-8 symbols as is. Enable EAN/JAN Zero Extend (01h) *Disable EAN/JAN Zero Extend (00h) UCC Coupon Extended Code Parameter # 55h Enable this parameter to decode UPC-A bar codes starting with digit ‘5’, EAN-13 bar codes starting with digit ‘99’, and UPC-A/GS1-128 Coupon Codes.
9 - 22 DS9208-1D Product Reference Guide Coupon Report Parameter # F1h DAh Traditional coupon symbols (old coupon symbols) are composed of two bar codes: UPC/EAN and Code128. A new coupon symbol is composed of a single Databar Expanded bar code. The new coupon format offers more options for purchase values (up to $999.99) and supports complex discount offers such as a second purchase requirement. An interim coupon symbol also exists that contains both types of bar codes: UPC/EAN and Databar Expanded.
Symbologies 9 - 23 ISSN EAN Parameter # F1h 69h To enable or disable ISSN EAN, scan the appropriate bar code below.
9 - 24 DS9208-1D Product Reference Guide Code 128 Enable/Disable Code 128 Parameter # 08h To enable or disable Code 128, scan the appropriate bar code below. *Enable Code 128 (01h) Disable Code 128 (00h) Set Lengths for Code 128 Parameter # L1 = D1h, L2 = D2h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 128 to any length, one or two discrete lengths, or lengths within a specific range.
Symbologies 9 - 25 Set Lengths for Code 128 (continued) Code 128 - One Discrete Length Code 128 - Two Discrete Lengths Code 128 - Length Within Range *Code 128 - Any Length Enable/Disable GS1-128 (formerly UCC/EAN-128) Parameter # 0Eh To enable or disable GS1-128, scan the appropriate bar code below.
9 - 26 DS9208-1D Product Reference Guide Enable/Disable ISBT 128 Parameter # 54h ISBT 128 is a variant of Code 128 used in the blood bank industry. Scan a bar code below to enable or disable ISBT 128. If necessary, the host must perform concatenation of the ISBT data.
Symbologies 9 - 27 ISBT Concatenation Parameter # F1h 41h Select an option for concatenating pairs of ISBT code types: • If you select Disable ISBT Concatenation, the digital scanner does not concatenate pairs of ISBT codes it encounters. • If you select Enable ISBT Concatenation, there must be two ISBT codes in order for the digital scanner to decode and perform concatenation. The digital scanner does not decode single ISBT symbols.
9 - 28 DS9208-1D Product Reference Guide Check ISBT Table Parameter # F1h 42h The ISBT specification includes a table that lists several types of ISBT bar codes that are commonly used in pairs. If you set ISBT Concatenation to Enable, enable Check ISBT Table to concatenate only those pairs found in this table. Other types of ISBT codes are not concatenated.
Symbologies 9 - 29 Code 39 Enable/Disable Code 39 Parameter # 00h To enable or disable Code 39, scan the appropriate bar code below. *Enable Code 39 (01h) Disable Code 39 (00h) Enable/Disable Trioptic Code 39 Parameter # 0Dh Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges. Trioptic Code 39 symbols always contain six characters. To enable or disable Trioptic Code 39, scan the appropriate bar code below.
9 - 30 DS9208-1D Product Reference Guide Convert Code 39 to Code 32 Parameter # 56h Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32. NOTE Code 39 must be enabled for this parameter to function.
Symbologies 9 - 31 Set Lengths for Code 39 Parameter # L1 = 12h, L2 = 13h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 39 to any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options.
9 - 32 DS9208-1D Product Reference Guide Code 39 Check Digit Verification Parameter # 30h Enable this feature to check the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm. Only Code 39 symbols which include a modulo 43 check digit are decoded. Enable this feature if the Code 39 symbols contain a Modulo 43 check digit.
Symbologies 9 - 33 Code 39 Full ASCII Conversion Parameter # 11h Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. Enable Code 39 Full ASCII (01h) *Disable Code 39 Full ASCII (00h) NOTE You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously.
9 - 34 DS9208-1D Product Reference Guide Code 39 Buffering Parameter # 71h This feature allows the digital scanner to accumulate data from multiple Code 39 symbols. Enabling Code 39 Buffering temporarily buffers all Code 39 symbols having a leading space as a first character for later transmission. The leading space is not buffered. Decoding a Code 39 symbol with no leading space transmits in sequence all buffered data in a first-in first-out format, plus the “triggering” symbol.
Symbologies 9 - 35 Clear Buffer NOTE Because the Clear Buffer bar code contains only the dash (minus) character, use Set Lengths for Code 39 to include length 1 in order to scan this command. Transmit Buffer There are two methods to transmit the Code 39 buffer. 1. Scan the Transmit Buffer bar code, which includes only a start character, a plus (+), and a stop character. 2. The digital scanner transmits and clears the buffer. • The digital scanner issues a low/high beep. Transmit Buffer 3.
9 - 36 DS9208-1D Product Reference Guide Code 93 Enable/Disable Code 93 Parameter # 09h To enable or disable Code 93, scan the appropriate bar code below. Enable Code 93 (01h) *Disable Code 93 (00h) Set Lengths for Code 93 Parameter # L1 = 1Ah, L2 = 1Bh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 93 to any length, one or two discrete lengths, or lengths within a specific range.
Symbologies 9 - 37 Set Lengths for Code 93 (continued) Code 93 - One Discrete Length Code 93 - Two Discrete Lengths *Code 93 - Length Within Range Code 93 - Any Length
9 - 38 DS9208-1D Product Reference Guide Code 11 Code 11 Parameter # 0Ah To enable or disable Code 11, scan the appropriate bar code below. Enable Code 11 (01h) *Disable Code 11 (00h) Set Lengths for Code 11 Parameter # L1 = 1Ch, L2 = 1Dh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 11 to any length, one or two discrete lengths, or lengths within a specific range.
Symbologies 9 - 39 Set Lengths for Code 11 (continued) Code 11 - One Discrete Length Code 11 - Two Discrete Lengths *Code 11 - Length Within Range Code 11 - Any Length
9 - 40 DS9208-1D Product Reference Guide Code 11 Check Digit Verification Parameter # 34h This feature allows the digital scanner to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 bar code. The options are to check for one check digit, check for two check digits, or disable the feature.
Symbologies 9 - 41 Transmit Code 11 Check Digits Parameter # 2Fh This feature selects whether or not to transmit the Code 11 check digit(s). Transmit Code 11 Check Digit(s) (Enable) (01h) *Do Not Transmit Code 11 Check Digit(s) (Disable) (00h) NOTE Code 11 Check Digit Verification must be enabled for this parameter to function.
9 - 42 DS9208-1D Product Reference Guide • One Discrete Length - Select this option to decode only I 2 of 5 symbols containing a selected length. Select the length using the numeric bar codes in Appendix D, Numeric Bar Codes. For example, to decode only I 2 of 5 symbols with 14 characters, scan I 2 of 5 - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page D-2.
Symbologies 9 - 43 Set Lengths for Interleaved 2 of 5 (continued) *I 2 of 5 - One Discrete Length I 2 of 5 - Two Discrete Lengths I 2 of 5 - Length Within Range I 2 of 5 - Any Length
9 - 44 DS9208-1D Product Reference Guide I 2 of 5 Check Digit Verification Parameter # 31h Enable this feature to check the integrity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification (USS), or the Optical Product Code Council (OPCC) check digit algorithm.
Symbologies 9 - 45 Convert I 2 of 5 to EAN-13 Parameter # 52h Enable this parameter to convert 14-character I 2 of 5 codes to EAN-13, and transmit to the host as EAN-13. To accomplish this, the I 2 of 5 code must be enabled, and the code must have a leading zero and a valid EAN-13 check digit.
9 - 46 DS9208-1D Product Reference Guide Set Lengths for Discrete 2 of 5 Parameter # L1 = 14h, L2 = 15h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for D 2 of 5 to any length, one or two discrete lengths, or lengths within a specific range. The range for Discrete 2 of 5 lengths is 0 - 55. • One Discrete Length - Select this option to decode only D 2 of 5 symbols containing a selected length.
Symbologies 9 - 47 Set Lengths for Discrete 2 of 5 (continued) *D 2 of 5 - One Discrete Length D 2 of 5 - Two Discrete Lengths D 2 of 5 - Length Within Range D 2 of 5 - Any Length
9 - 48 DS9208-1D Product Reference Guide Codabar (NW - 7) Enable/Disable Codabar Parameter # 07h To enable or disable Codabar, scan the appropriate bar code below. Enable Codabar (01h) *Disable Codabar (00h) Set Lengths for Codabar Parameter # L1 = 18h, L2 = 19h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Codabar to any length, one or two discrete lengths, or lengths within a specific range.
Symbologies 9 - 49 Set Lengths for Codabar (continued) Codabar - One Discrete Length Codabar - Two Discrete Lengths *Codabar - Length Within Range Codabar - Any Length
9 - 50 DS9208-1D Product Reference Guide CLSI Editing Parameter # 36h Enable this parameter to strip the start and stop characters and insert a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format. NOTE Symbol length does not include start and stop characters.
Symbologies 9 - 51 Codabar Upper or Lower Case Start/Stop Characters Detection Parameter # F2h 57h Select whether to detect upper case or lower case Codabar start/stop characters.
9 - 52 DS9208-1D Product Reference Guide MSI Enable/Disable MSI Parameter # 0Bh To enable or disable MSI, scan the appropriate bar code below. Enable MSI (01h) *Disable MSI (00h) Set Lengths for MSI Parameter # L1 = 1Eh, L2 = 1Fh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for MSI to any length, one or two discrete lengths, or lengths within a specific range.
Symbologies 9 - 53 Set Lengths for MSI (continued) NOTE Due to the construction of the MSI symbology, it is possible for a scan line covering only a portion of the code to transmit as a complete scan, yielding less data than is encoded in the bar code. To prevent this, select specific lengths (MSI - One Discrete Length, Two Discrete Lengths) for MSI applications.
9 - 54 DS9208-1D Product Reference Guide MSI Check Digits Parameter # 32h With MSI symbols, one check digit is mandatory and always verified by the reader. The second check digit is optional. If the MSI codes include two check digits, scan the Two MSI Check Digits bar code to enable verification of the second check digit. See MSI Check Digit Algorithm on page 9-55 for the selection of second digit algorithms.
Symbologies 9 - 55 MSI Check Digit Algorithm Parameter # 33h Two algorithms are possible for the verification of the second MSI check digit. Select the bar code below corresponding to the algorithm used to encode the check digit. MOD 10/MOD 11 (00h) *MOD 10/MOD 10 (01h) Chinese 2 of 5 Enable/Disable Chinese 2 of 5 Parameter # F0h 98h To enable or disable Chinese 2 of 5, scan the appropriate bar code below.
9 - 56 DS9208-1D Product Reference Guide Matrix 2 of 5 Enable/Disable Matrix 2 of 5 Parameter # F1h 6Ah To enable or disable Matrix 2 of 5, scan the appropriate bar code below.
Symbologies 9 - 57 Set Lengths for Matrix 2 of 5 Parameter # L1 = F1h 6Bh, L2 = F1h 6Ch The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Matrix 2 of 5 to any length, one or two discrete lengths, or lengths within a specific range. • One Discrete Length - Select this option to decode only Matrix 2 of 5 symbols containing a selected length.
9 - 58 DS9208-1D Product Reference Guide Matrix 2 of 5 Check Digit Parameter # F1h 6Eh The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the Matrix 2 of 5 check digit.
Symbologies 9 - 59 Korean 3 of 5 Enable/Disable Korean 3 of 5 Parameter # F1h 45h To enable or disable Korean 3 of 5, scan the appropriate bar code below. NOTE The length for Korean 3 of 5 is fixed at 6.
9 - 60 DS9208-1D Product Reference Guide Inverse 1D Parameter # F1h 4Ah This parameter sets the 1D inverse decoder setting. Options are: • Regular Only - the digital scanner decodes regular 1D bar codes only. • Inverse Only - the digital scanner decodes inverse 1D bar codes only. • Inverse Autodetect - the digital scanner decodes both regular and inverse 1D bar codes.
Symbologies 9 - 61 GS1 DataBar GS1 DataBar types are: • GS1 DataBar Omnidirectional • GS1 DataBar Truncated • GS1 DataBar Stacked • GS1 DataBar Stacked Omnidirectional • GS1 DataBar Limited • GS1 DataBar Expanded • GS1 DataBar Expanded Stacked Scan the appropriate bar codes to enable or disable each type of GS1 DataBar.
9 - 62 DS9208-1D Product Reference Guide GS1 DataBar Limited Parameter # F0h 53h Enable GS1 DataBar Limited (01h) *Disable GS1 DataBar Limited (00h)
Symbologies 9 - 63 GS1 DataBar Limited Security Level Parameter # F1h D8h The digital scanner offers four levels of decode security for GS1 DataBar Limited bar codes. There is an inverse relationship between security and digital scanner aggressiveness. Increasing the level of security may result in reduced aggressiveness in scanning, so only choose the level of security necessary. • Level 1 – No clear margin required.
9 - 64 DS9208-1D Product Reference Guide GS1 DataBar Expanded Parameter # F0h 54h Scan the appropriate bar code below to enable or disable the following code types: • GS1 DataBar Expanded • GS1 DataBar Expanded Stacked. *Enable GS1 DataBar Expanded (01h) Disable GS1 DataBar Expanded (00h) Convert GS1 DataBar to UPC/EAN Parameter # F0h, 8Dh This parameter only applies to GS1 DataBar and GS1 DataBar Limited symbols not decoded as part of a Composite symbol.
Symbologies 9 - 65 Redundancy Level Parameter # 4Eh The digital scanner offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of bar code quality. As redundancy levels increase, the digital scanner’s aggressiveness decreases. Select the redundancy level appropriate for the bar code quality.
9 - 66 DS9208-1D Product Reference Guide Redundancy Level 4 The following code types must be successfully read three times before being decoded: Table 9-5 Redundancy Level 4 Codes Code Type All Code Length All *Redundancy Level 1 (01h) Redundancy Level 2 (02h) Redundancy Level 3 (03h) Redundancy Level 4 (04h)
Symbologies 9 - 67 Security Level Parameter # 4Dh The digital scanner offers four levels of decode security for delta bar codes, which include UPC/EAN and Code 93. Select increasing levels of security for decreasing levels of bar code quality. There is an inverse relationship between security and digital scanner aggressiveness, so choose only that level of security necessary for any given application.
9 - 68 DS9208-1D Product Reference Guide Intercharacter Gap Size Parameter # F0h, 7Dh The Code 39 and Codabar symbologies have an intercharacter gap that is typically quite small. Due to various bar code-printing technologies, this gap can grow larger than the maximum size allowed, preventing the digital scanner from decoding the symbol. If this problem occurs, scan the Large Intercharacter Gaps parameter to tolerate these out-of-specification bar codes.
CHAPTER 10 123SCAN2 Introduction 123Scan² is an easy to use, PC-based software tool that enables rapid customized setup of Motorola decoders. 123Scan² uses a wizard tool to guide users through a streamlined set up process. Settings are saved in a configuration file that can be distributed via e-mail, electronically downloaded via a USB cable, or used to generate a sheet of scannable programming bar codes.
10 - 2 DS9208-1D Product Reference Guide 123Scan2 Requirements • Host computer with Windows XP SP2 or Windows 7 • Scanner • Cradle • USB cable. For more information on123Scan², go to: http://www.motorolasolutions.com/123Scan For a 1 minute tour of 123Scan², go to: http://www.motorolasolutions.com/scannerhowtovideos To download 123Scan² software and access the Help file integrated in the utility, go to: http://support.symbol.com/support/product/123Scan2.
CHAPTER 11 ADVANCED DATA FORMATTING Introduction Advanced Data Formatting (ADF) is a means of customizing data before transmission to the host device. Use ADF to edit scan data to suit requirements. Implement ADF by scanning a related series of bar codes which program the digital scanner with ADF rules. For information and programming bar codes for ADF, refer to the Advanced Data Formatting Programmer Guide, p/n 72E-69680-xx.
11 - 2 DS9208-1D Product Reference Guide
APPENDIX A STANDARD DEFAULT PARAMETERS Table A-1 Standard Default Parameters Table Parameter Parameter Number Default Page Number User Preferences Set Default Parameter Set Defaults 4-4 Parameter Bar Code Scanning ECh Enable 4-5 Beep After Good Decode 38h Enable 4-5 Beeper Tone 91h Medium 4-6 Beeper Volume 8Ch High 4-7 Volume Adjustment Trigger Timeout F0h 93h 5.
A-2 DS9208-1D Product Reference Guide Table A-1 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number Post Decode Illumination F2h 29h Always Off 4-18 Illumination Always On (Presentation Mode Only) F2h 59h Illumination Automatically Controlled 4-19 Presentation Mode Field of View F1h 61h Full 4-20 Picklist Mode F0h 92h Enabled in Trigger Mode 4-21 Continuous Bar Code Read F1h 89h Disable 4-22 Unique Bar Code Reporting F1h D31h Disable 4-2
Standard Default Parameters Table A-1 A-3 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number USB Convert Unknown to Code 39 Disable 5-10 USB Ignore Beep Directive Honor 5-11 USB Ignore Type Directive Honor 5-11 Emulate Keypad Disable 5-12 Emulate Keypad with Leading Zero Disable 5-12 USB Keyboard FN1 Substitution Disable 5-13 Function Key Mapping Disable 5-13 Convert Case No Case Conversion 5-14 USB Static CDC Enable 5-14 USB Pollin
A-4 DS9208-1D Product Reference Guide Table A-1 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number IBM 468X/469X Host Parameters Port Address None Selected 7-4 Convert Unknown to Code 39 Disable 7-5 Ignore Beep Directive Honor 7-5 Ignore Configuration Directive Honor 7-6 Keyboard Wedge Host Type IBM PC/AT& IBM PC Compatibles1 8-4 Country Types (Country Codes) North American 8-5 Ignore Unknown Characters Transmit 8-7 Keystroke Delay No De
Standard Default Parameters Table A-1 A-5 Standard Default Parameters Table (Continued) Parameter Decode UPC/EAN/JAN Supplementals (2 and 5 digits) Parameter Number 10h Default Ignore Page Number 9-11 User-Programmable Supplementals Supplemental 1: Supplemental 2: F1h 43h F1h 44h 9-14 UPC/EAN/JAN Supplemental Redundancy 50h 10 9-14 Decode UPC/EAN/JAN Supplemental AIM ID F1h A0h Combined 9-15 Transmit UPC-A Check Digit 28h Enable 9-16 Transmit UPC-E Check Digit 29h Enable 9-16 Tran
A-6 DS9208-1D Product Reference Guide Table A-1 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number Code 39 Code 39 00h Enable 9-29 Trioptic Code 39 0Dh Disable 9-29 Convert Code 39 to Code 32 (Italian Pharmacy Code) 56h Disable 9-30 Code 32 Prefix E7h Disable 9-30 Set Length(s) for Code 39 12h, 13h 2 to 55 9-31 Code 39 Check Digit Verification 30h Disable 9-32 Transmit Code 39 Check Digit 2Bh Disable 9-32 Code 39 Full ASCII Convers
Standard Default Parameters Table A-1 A-7 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number Codabar (NW - 7) Codabar 07h Disable 9-48 Set Lengths for Codabar 18h, 19h 5 to 55 9-48 CLSI Editing 36h Disable 9-50 NOTIS Editing 37h Disable 9-50 Codabar Upper or Lower Case Start/Stop Characters Detection F2h 57h Lower Case 9-51 MSI 0Bh Disable 9-52 Set Length(s) for MSI 1Eh, 1Fh 4 to 55 9-52 MSI Check Digits 32h One 9-54 Transmit M
A-8 DS9208-1D Product Reference Guide Table A-1 Standard Default Parameters Table (Continued) Parameter Parameter Number Default Page Number GS1 DataBar Expanded (GS1 DataBar Expanded, GS1 DataBar Expanded Stacked) F0h 54h Enable 9-64 Convert GS1 DataBar to UPC/EAN F0h 8Dh Disable 9-64 Redundancy Level 4Eh 1 9-65 Security Level (UPC/EAN and Code 93) 4Dh 0 9-67 Intercharacter Gap Size F0h 7Dh Normal 9-68 Symbology-Specific Security Levels 1 User selection is required to configure
APPENDIX B PROGRAMMING REFERENCE Symbol Code Identifiers Table B-1 Symbol Code Characters Code Character Code Type A UPC-A, UPC-E, UPC-E1, EAN-8, EAN-13 B Code 39, Code 32 C Codabar D Code 128, ISBT 128, ISBT 128 Concatenated E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5, or Discrete 2 of 5 IATA H Code 11 J MSI K GS1-128 L Bookland EAN M Trioptic Code 39 N Coupon Code R GS1 DataBar Family S Matrix 2 of 5 U Chinese 2 of 5 V Korean 3 of 5 X ISSN EAN
B-2 DS9208-1D Product Reference Guide AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character (ASCII 93) c = Code Character (see Table B-2) m = Modifier Character (see Table B-3) Table B-2 Aim Code Characters Code Character Code Type A Code 39, Code 39 Full ASCII, Code 32 C Code 128, ISBT 128, ISBT 128 Concatenated, GS1-128, Coupon (Code 128 portion) E UPC/EAN, Coupon (UPC portion) e GS1 DataBar Family F Codabar G Code 93 H Code 11
Programming Reference B-3 The modifier character is the sum of the applicable option values based on Table B-3. Table B-3 Modifier Characters Code Type Code 39 Option Value Option 0 No check character or Full ASCII processing. 1 Reader has checked one check character. 3 Reader has checked and stripped check character. 4 Reader has performed Full ASCII character conversion. 5 Reader has performed Full ASCII character conversion and checked one check character.
B-4 DS9208-1D Product Reference Guide Table B-3 Modifier Characters (Continued) Code Type D 2 of 5 Option Value 0 Option No options specified at this time. Always transmit 0. Example: A D 2 of 5 bar code 4123, is transmitted as ]S04123 UPC/EAN 0 Standard data packet in full EAN format, i.e. 13 digits for UPC-A, UPC-E, and EAN-13 (not including supplemental data). 1 Two digit supplemental data only. 2 Five digit supplemental data only.
APPENDIX C SAMPLE BAR CODES Code 39 123ABC UPC/EAN UPC-A, 100% 0 12345 67890 5
C-2 DS9208-1D Product Reference Guide EAN-13, 100% 3 456789 012340 Code 128 1234567890 Interleaved 2 of 5 12345678901231
Sample Bar Codes GS1 DataBar-14 NOTE DataBar-14 must be enabled to read the bar code below (see GS1 DataBar on page 9-61).
C-4 DS9208-1D Product Reference Guide
APPENDIX D NUMERIC BAR CODES Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).
D-2 DS9208-1D Product Reference Guide Numeric Bar Codes (continued) 5 6 7 8 9 Cancel To correct an error or change a selection, scan the bar code below.
APPENDIX E ASCII CHARACTER SETS Table E-1 ASCII Value Table ASCII Value Full ASCII Code 39 Encode Char Keystroke 1000 %U CTRL 2 1001 $A CTRL A 1002 $B CTRL B 1003 $C CTRL C 1004 $D CTRL D 1005 $E CTRL E 1006 $F CTRL F 1007 $G CTRL G 1008 $H CTRL H/BACKSPACE1 1009 $I CTRL I/HORIZONTAL TAB1 1010 $J CTRL J 1011 $K CTRL K 1012 $L CTRL L 1013 $M CTRL M/ENTER1 1014 $N CTRL N 1015 $O CTRL O The keystroke in bold transmits only if you enabled Function Key Mapping
E-2 DS9208-1D Product Reference Guide Table E-1 ASCII Value Table (Continued) ASCII Value Full ASCII Code 39 Encode Char Keystroke 1016 $P CTRL P 1017 $Q CTRL Q 1018 $R CTRL R 1019 $S CTRL S 1020 $T CTRL T 1021 $U CTRL U 1022 $V CTRL V 1023 $W CTRL W 1024 $X CTRL X 1025 $Y CTRL Y 1026 $Z CTRL Z 1027 %A CTRL [ 1028 %B CTRL \ 1029 %C CTRL ] 1030 %D CTRL 6 1031 %E CTRL - 1032 Space Space 1033 /A ! 1034 /B “ 1035 /C # 1036 /D $ 1037 /E % 10
ASCII Character Sets Table E-1 ASCII Value Table (Continued) Full ASCII Code 39 Encode Char ASCII Value Keystroke 1045 - - 1046 . .
E-4 DS9208-1D Product Reference Guide Table E-1 ASCII Value Table (Continued) ASCII Value Full ASCII Code 39 Encode Char Keystroke 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 %K [ 1092 %L \ 1093 %M ] 1094 %N ^ 1095 %O _ 1096 %W ‘ 1097 +A a 1098 +B b 1099 +C c 1100 +D d 1101 +E e 1102 +F f The keystroke i
ASCII Character Sets Table E-1 ASCII Value Table (Continued) ASCII Value Full ASCII Code 39 Encode Char Keystroke 1103 +G g 1104 +H h 1105 +I i 1106 +J j 1107 +K k 1108 +L l 1109 +M m 1110 +N n 1111 +O o 1112 +P p 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1117 +U u 1118 +V v 1119 +W w 1120 +X x 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q I 1125 %R } 1126 %S ~ The keystroke in bold transmits only if you enabled Function Key Mapping.
E-6 DS9208-1D Product Reference Guide Table E-2 ALT Key Standard Default Tables ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z
ASCII Character Sets Table E-3 USB GUI Key Character Set GUI Key Keystroke 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P 3081 GUI Q Note: GUI Shift Keys - The Apple™ iMac keyboard has an ap
E-8 DS9208-1D Product Reference Guide Table E-3 USB GUI Key Character Set (Continued) GUI Key Keystroke 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Note: GUI Shift Keys - The Apple™ iMac keyboard has an apple key on either side of the space bar. Windows-based systems have a GUI key to the left of the left ALT key, and to the right of the right ALT key.
ASCII Character Sets Table E-4 PF Key Standard Default Table PF Keys Keystroke 4001 PF 1 4002 PF 2 4003 PF 3 4004 PF 4 4005 PF 5 4006 PF 6 4007 PF 7 4008 PF 8 4009 PF 9 4010 PF 10 4011 PF 11 4012 PF 12 4013 PF 13 4014 PF 14 4015 PF 15 4016 PF 16 E-9
E - 10 DS9208-1D Product Reference Guide Table E-5 F key Standard Default Table F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F 10 5011 F 11 5012 F 12 5013 F 13 5014 F 14 5015 F 15 5016 F 16 5017 F 17 5018 F 18 5019 F 19 5020 F 20 5021 F 21 5022 F 22 5023 F 23 5024 F 24
ASCII Character Sets E - 11 Table E-6 Numeric Key Standard Default Table Numeric Keypad Keystroke 6042 * 6043 + 6044 Undefined 6045 - 6046 .
E - 12 DS9208-1D Product Reference Guide Table E-7 Extended Keypad Standard Default Table Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Dn Arrow 7017 Left Arrow 7018 Right Arrow
GLOSSARY A Aperture. The opening in an optical system defined by a lens or baffle that establishes the field of view. API. An interface by means of which one software component communicates with or controls another. Usually used to refer to services provided by one software component to another, usually via software interrupts or function calls Application Programming Interface. See API. ASCII. American Standard Code for Information Interchange.
Glossary - 2 DS9208-1D Product Reference Guide Bit. Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its meaning. Bits per Second (bps). Bits transmitted or received. Boot or Boot-up. The process a computer goes through when it starts. During boot-up, the computer can run self-diagnostic tests and configure hardware and software. BOOTP.
Glossary - 3 Code Length. Number of data characters in a bar code between the start and stop characters, not including those characters. Cold Boot. A cold boot restarts the mobile computer and erases all user stored records and entries. COM port. Communication port; ports are identified by number, e.g., COM1, COM2. Continuous Code. A bar code or symbol in which all spaces within the symbol are parts of characters. There are no intercharacter gaps in a continuous code.
Glossary - 4 DS9208-1D Product Reference Guide F Flash Disk. An additional megabyte of non-volatile memory for storing application and configuration files. Flash Memory. Flash memory is responsible for storing the system firmware and is non-volatile. If the system power is interrupted the data is not be lost. FTP. See File Transfer Protocol. H Hard Reset. See Cold Boot. Host Computer.
Glossary - 5 I/O Ports. interface The connection between two devices, defined by common physical characteristics, signal characteristics, and signal meanings. Types of interfaces include RS-232 and PCMCIA. IOCTL. Input/Output Control. IP Address. (Internet Protocol address) The address of a computer attached to an IP network. Every client and server station must have a unique IP address. A 32-bit address used by a computer on a IP network.
Glossary - 6 DS9208-1D Product Reference Guide M MIL. 1 mil = 1 thousandth of a meter. Misread (Misdecode). A condition which occurs when the data output of a reader or interface controller does not agree with the data encoded within a bar code symbol. N Nominal. The exact (or ideal) intended value for a specified parameter. Tolerances are specified as positive and negative deviations from this value. Nominal Size. Standard size for a bar code symbol.
Glossary - 7 Percent Decode. The average probability that a single scan of a bar code would result in a successful decode. In a well-designed bar code scanning system, that probability should approach near 100%. PING. (Packet Internet Groper) An Internet utility used to determine whether a particular IP address is online. It is used to test and debug a network by sending out a packet and waiting for a response. Presentation Mode.
Glossary - 8 DS9208-1D Product Reference Guide S Scan Area. Area intended to contain a symbol. Scanner. An electronic device used to scan bar code symbols and produce a digitized pattern that corresponds to the bars and spaces of the symbol.
Glossary - 9 Symbol Aspect Ratio. The ratio of symbol height to symbol width. Symbol Height. The distance between the outside edges of the quiet zones of the first row and the last row. Symbol Length. Length of symbol measured from the beginning of the quiet zone (margin) adjacent to the start character to the end of the quiet zone (margin) adjacent to a stop character. Symbology. The structural rules and conventions for representing data within a particular bar code type (e.g.
Glossary - 10 DS9208-1D Product Reference Guide ignored, because there is no time to retransmit. If UDP is used and a reliable delivery is required, packet sequence checking and error notification must be written into the applications. UPC. Universal Product Code. A relatively complex numeric symbology. Each character consists of two bars and two spaces, each of which is any of four widths. The standard symbology for retail food packages in the United States. V Visible Laser Diode (VLD).
INDEX Numerics 123Scan2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1 A accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 interface cable . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 optional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 ADF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xv, 11-1 advanced data formatting . . . . .
Index - 2 DS9208-1D Product Reference Guide I 2 of 5 check digit verification . . . . . . . . . . . . . . 9-44 I 2 of 5 convert to EAN-13 . . . . . . . . . . . . . . . . . 9-45 I 2 of 5 transmit check digit . . . . . . . . . . . . . . . . 9-44 IBM 468X/469X convert unknown to code 39 . . . . . . . . . . . . . 7-5 default parameters . . . . . . . . . . . . . . . . . . . . 7-3 ignore beep directive . . . . . . . . . . . . . . . . . . 7-5 ignore configuration directive . . . . . . . . . . . .
Index - 3 polling interval . . . . . . . . . . . . . . . . . . 5-15, 5-16 quick keypad emulation . . . . . . . . . . . . . . . 5-17 simulated caps lock . . . . . . . . . . . . . . . . . . . 5-9 SNAPI handshaking . . . . . . . . . . . . . . . . . . . 5-5 static CDC . . . . . . . . . . . . . . . . . . . . . . . . . 5-14 transmission speed . . . . . . . . . . . . . . . . . . 5-15 unknown characters . . . . . . . . . . . . . . . . . . 5-10 beeper beep after good decode . . . . . . . . . . . . . . . . . . .
Index - 4 DS9208-1D Product Reference Guide I P IBM 468X/469X connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 default parameters . . . . . . . . . . . . . . . . . . . . . . . 7-3 parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4 illumination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18 illumination always on . . . . . . . . . . . . . . . . . . . . 4-19 post decode . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index - 5 U unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 UPC/EAN bar codes bookland EAN . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-9 bookland ISBN . . . . . . . . . . . . . . . . . . . . . . . . . 9-10 check digit . . . . . . . . . . . . . . . . . . . . . . . . . 9-16, 9-17 convert UPC-E to UPC-A . . . . . . . . . . . . . . . . . 9-20 convert UPC-E1 to UPC-A . . . . . . . . . . . . . . . . 9-20 coupon report . . . . . . . . . . . . . . . . . . . . . . . . . .
Index - 6 DS9208-1D Product Reference Guide
Tell Us What You Think... We’d like to know what you think about this Manual. Please take a moment to fill out this questionnaire and fax this form to: (631) 627-7184, or mail to: Motorola Solutions, Inc. One Motorola Plaza M/S B-10 Holtsville, NY 11742-1300 Attention: Advanced Data Capture Technical Publications Manager Important If you need product support, please call the appropriate customer support number provided. Unfortunately, we cannot provide customer support at the fax number above.
Motorola Solutions, Inc. One Motorola Plaza Holtsville, New York 11742, USA 1-800-927-9626 http://www.motorolasolutions.com MOTOROLA, MOTO, MOTOROLA SOLUTIONS and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings, LLC and are used under license. All other trademarks are the property of their respective owners. © 2012 Motorola Solutions, Inc. All Rights Reserved.