IN-WALL DIMMER ML IWD 600S DESIGNER SERIES I N S TALL ATION & U S ER GUIDE
MONSTER® ILLUMINESSENCE™ PRODUCTS: Dimmable Table & Floor Lamps Plug In Light Station Dimmer ML LD 300 ON/OFF Compact Fluorescent Lights & Appliances Plug In Light & Appliance Station Dimmer ML LAS 1000 Dimmable Ceiling Lights Table & Floor Lamps In Wall Dimmer ML IWD 600S ON/OFF Ceiling Fluorescents Table & Floor Lamps In Wall Switch ML IWS 1000S Controls All or Selected Lights at the Push of a Button In Wall Scene Controller ML IWC 600 INTRODUCTION MONSTER® ILLUMINESSENCE™: POWERFUL WHOLE HOME LIGHTI
through floors, walls, ceilings and cabinets. IlluminEssence scene-capable dimmer modules are compatible with any Z-Wave™ enabled network, regardless of the manufacturer, and can also be used with other devices displaying the Z-Wave logo. • Dimmer may feel warm to the touch during normal operation. • Recommended minimum wall box depth is 2-1/2". • Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture. • Do not exceed the 600W rating as shown on the safety label.
• If you are unsure about any part of these instructions, consult a qualified electrician. • This device is intended for indoor use only.
BLACK or WHITE may be the color neutral. 5) Remove the caps or screws on your existing dimmer to release the wires.
INSTALLING YOUR DIMMER STEP 2: STEP 1: IDENTIFY YOUR WIRING: WARNING: to avoid, fire, shock or death, turn off the power at the circuit breaker or fuse and test that power is OFF before wiring! NOTE: This diagram represents a typical single-pole, 2-way wiring configuration. This is for one dimmer controlling one load of lights. 8 ��� �� ��� �� ��� �� ��� �� ��� �� ��� �� ��� �� ��� �� ��� �� ��� �� ��� �� ��� �� Single-Pole 1. Line (Hot) 2. Neutral 3. Ground 4.
STEP 3: STEP 4: PREPARING AND CONNECTING WIRES: SINGLE POLE WIRING: This dimmer can be wired using side wire terminal screws or through backwire openings. Choose the appropriate wire stripping specifications accordingly. Cut (if necessary) Strip Gage (measure bare wire here) Side Wire Connection Side wire terminals accept #14 AWG solid copper wire only. 5/8" (1.6 cm) Back Wire (either hole may be used) Back wire openings use #14-12 AWG solid copper wire only.
WIRING DIMMER: STEP 5: Connect wires per WIRING DIAGRAM as follows: TESTING YOUR DIMMER BEFORE MOUNTING ������ �� �� ����������� ������������ ����� ����� ���� ����� �������������������������� ���������������������������� �������������������������� ������������������������� ���� �������� ���� ��������������� • The Green or bare copper wire in wall box goes to the Green terminal screw. • Line Hot wall box wire goes to the terminal screw marked “BK”.
STEP 6: PAIRING YOUR ILLUMINESSENCE IN-WALL DIMMER INTO THE NETWORK Locator Light 1) Follow the instructions on your Monster Controller/Programmer to Pair a Monster IlluminEssence™ or other Z-Wave-enabled lighting station into the lighting network. When it’s ready to Pair a new device, proceed to Step 2. • Restore power at the circuit breaker or fuse. • Press pad until locator light is OFF. Lights should turn ON.
2) While standing close to the dimmer (approximately 2-5 ft.) with the controller in hand, press the center button on the dimmer to Pair it in the network. NOTE: Only one device may be Paired at a time. DO NOT put multiple devices into the Pairing mode at any time. 3) While the Controller/Programmer is in the Pairing mode and the Locator LED is ON on the dimmer, press the push pad to turn on the dimmer. The Programmer/Controller will verify the Pairing and the Locator LED will turn OFF on the dimmer.
STEP 7: REMOVING/EXCLUDING AN ILLUMINESSENCE IN-WALL DIMMER FROM THE NETWORK 1) Follow the instructions on your Monster Controller/Programmer to Remove a Monster IlluminEssence™ or other Z-Wave-enabled lighting station from the lighting network. When it’s ready to Remove the device that you want Removed, proceed to Step 2. LED is ON on the dimmer, press the push pad to turn on the dimmer. The Programmer/Controller will verify Removal and the locator LED will turn OFF.
Factory Default: If your dimmer is not responding, or you are unable to control it after you have tried to Pair or Remove it multiple times, it may be necessary to reset the dimmer to its original factory settings. To do this, proceed as follows: until the locator LED flashes Amber and turns solid Red. The dimmer is now reset. Once the dimmer is reset, it will be necessary to re-Pair it to a network before it can be used.
STEP 8: OPERATION MOUNTING THE DIMMER For complete details on operating your lighting within a Monster ControlNet™ or other Z-Wave-enabled network, refer to the instruction guide of your Monster Central or other lighting controller. • TURN OFF POWER AT THE CIRCUIT BREAKER OR FUSE! NOTE: The locator light will illuminate when the load is in the OFF position to facilitate access in the dark. Turn ON from OFF position: Installation may now be completed by tightening mounting screws into wall box.
DIM/BRIGHT Bar BRIGHTEN: Press upper half of DIM/BRIGHT Bar – Lights brighten to desired level. DIM: Press lower half of DIM/BRIGHT Bar – the light will dim to the desired level. If you continue to hold the lower half of the DIM/BRIGHT Bar, the lights will DIM to minimum level and then turn OFF. NOTE: When lights are OFF you can change the light level that the lights will turn ON to using the DIM/BRIGHT Bar.
ADVANCED PROGRAMMING FEATURES Your Monster IlluminEssence™ in-wall dimmer is capable of personalized operations that will bring your lighting to your preferred settings under a variety of everyday situations and conditions: Advanced Features Summary Mode 1 Description Set Min.
Preset 1* * ** *** Fade Rate Presets LED** Fade On Fade Off 1 Approx. 1.5s Approx. 3s from full off from full on 2*** 2 No Fade No Fade 3 3 No Fade Approx. 3s from full on 4 4 Approx. 0.5s from full off Approx. 3s from full on 5 5 Approx. 0.5s from full off Approx. 1.5s from full on 6 6 Approx. 1.5s from full off Approx. 5s from full on 7 7 Approx. 1.5s from full off Approx.
TROUBLESHOOTING LIGHTS ARE FLICKERING. • Lamp has a bad connection. • The wires are not secured firmly under terminal screws of dimmer and/or remote. • The lamp may not be designed for true dimmable control such as non-dimmable fluorescent lighting. LIGHT DOES NOT TURN ON AND LOCATOR LED DOES NOT TURN ON • Circuit breaker or fuse has tripped. • Lamp is burned out. • Lamp Neutral connection is not wired. • Confirm that the device is being supplied from a 120V, 60Hz AC source ONLY.
FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
“Formal Warranty Claim” means a claim made in accordance with the section “Formal Warranty Claims” herein. “Product” means a Product (i) that is listed in the Specifications Table below, (ii) that You bought from an Authorized Dealer new and in its original packaging, and (iii) whose serial number, if any, has not been removed, altered, or defaced.
other commercial use, or (iii) from someone other than an Authorized Dealer. SCOPE OF THIS LIMITED WARRANTY PRODUCTS.
SPECIFICATIONS TABLE Product Model Warranty Period for Product ML IWD 600S Three (3) Years FORMAL WARRANTY CLAIM HOW TO MAKE A CLAIM.
MonsterCentral.com © 2006 Monster, LLC 7251 West Lake Mead Blvd. Las Vegas, NV 89128, USA 1-877-800-8989 Monster Central products are designed in the USA and manufactured for Monster to its quality specifications. Manufactured in Mexico. Monster, Monster Central, the Monster Central logo and the product design, Omnilink, Monster System Tracking Memory, IlluminEssence, ControlNet, are registered or unregistered trademarks of Monster Cable Products, Inc. or its subsidiaries in the US and other countries.