Parts List/Tune Up Info

Tune up procedure
Tune up procedure shall be over the power range or at specific operating power levels.
1.
It must provide an operational voltage (3.6 ~ 4.35V DC) to turn onthe device and on
one certain channel in service mode by means of company proprietary software.
2. . The Base station simulator measures this device for their specific RF
characteristics.
3.
The maximum gains of each individual device are adjusted until the target value
met.
RF average conduct power range
1.
GSM850
Output power of range:
GSM/GPRS (GMSK):
GSM:32.5dBm±0.5dBm
1TXslots:32.5dBm±0.5dBm
2TXslots:29.5dBm±0.6dBm
3TXslots:28dBm±0.5dBm
4TXslots:26.5dBm±0.8dBm
EGPRS:
1TXslots:27dBm±1dBm
2TXslots:26dBm±1dBm
3TXslots:24dBm±1dBm
4TXslots:23dBm±1dBm
2.
PCS1900
Output power of range:
GSM/GPRS (GMSK):
GSM: 29dBm±1dBm
1TXslot:29dBm±1dBm
2TXslots:28.5dBm±1dBm
3TXslots:27dBm±0.5dBm
4TXslots:26dBm±0.5dBm
EGPRS:
1TXslots:26dBm±1dBm
2TXslots:25dBm±1dBm
3TXslots:23dBm±1dBm
4TXslots:22dBm±1dBm
3.
WCDMA
WCDMA1900: PWR =21.5±1.5dBm
WCDMA850: PWR = 21.5±1.5dBm
LTE 7 PWR =21±2dBm
4.
BT
BT:4dBm±1dBmBasic Rate
BLE:4dBm±1dBm
5.
1.8 WIFI

Summary of content (2 pages)