A Series | Mitsubishi | A0 | A1 | A2 | A3 In Stock | There Tomorow | RyansElectric.com Mitsubishi MELSEC - A Series Platform Presented by - RYANS Electric and Supply Company, Inc. For Product Needs: Email: sales@RyansElectric.com CALL: 1-800-601-0896 FAX: 1-336-855-7415 Check out a partial listing of products we carry at http://www.RyansElectric.com Mitsubishi MELSEC A-Series RYANS ELECTRIC & SUPPLY Company RyansElectric.
PROGRAMMABLE CONTROLLERS MELSEC QnA/A m o c .
Function, Performance, F A superior combination for a su Flexible network configurations, powerful programming tools, and a wide product range m the QnA/A series the right choice for every level o factory automation. m o c .
Contents Flexibility: uperior product make of A Unit for Every Application Need 3 QnA Series CPUs 4 A Series CPUs 5 QnA CPU Features 7 A CPU Features 8 Q4ARCPU Redundancy 9 CPU Base Units and Cables 13 Power Supplies and Memory Modules 14 Input Modules 15 Output Modules 16 Analog Modules 17 Positioning Modules 21 m o High Speed Counter Modules 25 Ultrasonic Linear Scale Interface Module 26 c .
A Unit for Every Application Need Series name Picture QnA I/O points Q4ARCPU Q4ACPU Q3ACPU Q2ACPU-S1 Q2ACPU High performance, multi-function CPU With new developments such as multiple program sequencing and global and local devices along with a bevy of new commands for special function modules, the QnACPU is the perfect solution for a wide range of factory automation needs.
QnA Series CPUs ■ Specifications of QnA/Q4ARCPU Item Q4ARCPU Control method I/O control method Program language Local I/O Incl. remote Capacity No. of modules Max. I/O capacity Program size No. of commands Processing speed LD (µs) MOV (µs) Total Bit devices Device memory (point) Timers counters Word devices File register Pointers (point) Index register (point) Devices for subroutine call with arguments Capacity No. of files Data a y Real time clock 5VDC consumption (A) R m o c .
A Series CPUs ■ Specifications of AnU, AnA and AnN CPUs Item A4UCPU Control system I/O control method Programming language Sequence instructions Basic instructions Application instructions Processing speed (sequence instruction) Total incl.
A Series CPUs A3ACPU (P21/R21) A2ACPU-S1 (P21/R21) A2ACPU A3NCPU A2NCPU-S1 A2NCPU (P21/R21) (P21/R21) (P21/R21) (P21/R21) Repeated operation using stored program Refresh mode (direct mode can be used partially Refresh mode or direct mode (switchable) in accordance with the instruction) A1NCPU (P21/R21) Language dedicated to sequence control. Combined use of relay symbol type and logic symbol type. 25 235 26 238 234 N/A 1.0–2.3µsec/step in direct mode, 1.
QnA CPU Features ■ High speed processing The requirement for faster processing speed of PLC systems will never end because faster processing means shorter production time, more precise control, and better quality in applications. MSP (Mitsubishi Sequence Processor) performance has been greatly improved compared to the types used in AnA/AnUCPU. QnACPUs gives roughly 3 times faster processing speed than AnUCPUs. LD X (input) OUT T (timer) MOV + Q4ARCPU Q4ACPU 0.075µs 0.60µs 0.225µs 0.
A CPU Features A1NCPU A2UCPU A2ACPU A2NCPU A2UCPU-S1 A2ACPU-S1 A2NCPU-S1 A4UCPU A3UCPU A3ACPU A3NCPU m o ■ Large memory/program capacity ■ Extended networking functions The A Series enables choice of memory size by removable memory cassette construction so that users can find the most economical memory size. From the smallest 16k byte memory cassette, A3NMCA-2, to the largest 1M byte, A4UMCA-128, 9 different memory cassette sizes are available.
Q4ARCPU Redundancy The Q4ARCPU system has been specially designed for process control applications that require redundancy of PLCs and extensive process control features. Using state-of-the-art QnA PLC technology as its base architecture, the Q4ARCPU has a number of added features. Q4ARCPU system ■ Configurations process control features. The dual power supply system provides redundancy of power supply modules only with the extensive process control features.
Q4ARCPU Redundancy ■ Hot/Stand-by operation ■ Program tracking The Q4ARCPU’s dual CPU system provides hot/stand-by operations for PLCs. When the hot CPU is operating normally, all the I/O modules are controlled by the hot CPU. During that time, the stand-by CPU does not execute its program, but copies the internal device data of the hot CPU.
Q4ARCPU Redundancy ■ Redundancy PC network system ● Existing PCs and Redundancy PCs can be combined on the same network.
Q4ARCPU Redundancy Item Input voltage Input frequency Max. input VA Inrush current Rated output Over current protection Over voltage protection Efficiency Power indication Terminal screw size Applicable wire size Allowable power interruption Withstand voltage External signal ■ A61RP Power supply module Specification 100-120/200-240VAC +10/-15% 50/60Hz +/-5% 110VA 20A within 8ms 5VDC 8A Over 8.8A 5.5 to 6.5VDC 65% or better LED M4 0.75 to 2 sq-mm 20ms or less 1500VAC 1min.
CPU Base Units and Cables ■ CPU base units One CPU base unit is required for each AnU, AnA, AnN or QnA system. Each allows for one power supply module, one CPU module, and a maximum of either 2, 5 or 8 single slot size I/O modules. At either end of the base unit there is an expansion port for the connection of extension bases. Item Maximum number of I/O modules Extension base connection Installation hole size External dimensions mm (inch) A32B-E 2 Not possible A35B-E A38B-E 5 8 Possible Possible 6mm (0.
Power Supplies and Memory Modules ■ Power supply modules Each A Series system requires at least one power supply module inserted into the CPU base. Additional power supplies are necessary if A65B or A68B extension base units are used in the system configuration. The power supply requires an external power source of either 100/120VAC or 200/240VAC for A61P, A62P, A61PEU, A62PEU & A65P, 24VDC for A63P.
Input Modules A complete range of input modules, suitable for all types of input devices. There are over 16 different input modules available for use with the QnA and AnU, AnA, AnN Series, covering a wide range of voltages. From AC types to DC types, and even sensor input modules, you can choose the one which is correct for your application needs. They are available in 16, 32 or 64 point densities. All of them feature LED operation indicators and screen printed wiring diagrams on the front of the module.
Output Modules A full line up of output modules for all your automation needs With over 30 types to choose from, the range of output modules available for use with the QnA and AnU, AnA, AnN Series cover nearly every automation output device you will ever use. There are four different types of output modules within the range, relay, triac/SSR, transistor, and TTL output types. Each come in 16 or 32 output point densities. The transistor output type is also available with 64 points/module.
Analog Modules ■ A68AD/A68AD-S2 Analog input modules m o ■ Intelligent A/D conversion using built-in microprocessors Analog input modules are available for all MELSEC QnA/A Series PLCs. Each is capable of accepting either current or voltage variable input signals.
Analog Modules ■ Analog output modules ■ Intelligent D/A conversion using built-in microprocessors Analog output modules are available for all MELSEC QnA/A Series PLCs.
Analog Modules ■ A616 Series analog modules ■ High speed, high density analog modules for advanced applications channels per base module. The multiplexer units are available in three different types. One which provides isolated channels; another which gives non-isolated channels, and one which is for use with the thermocouple input module. The A616 high density modules provide increased power and more flexible analog I/O capability.
Analog Modules ■ A616TD, A68RD3/4 Thermocouple input modules m o The A616TD thermocouple input module has the additional function of accepting other temperature sensing devices which produce an analog input. Connection with a multiplexing unit A60MX/MXT/MXR is also possible; providing up to 960 sensor inputs. The A616TD and A68RD3/4 thermocouple input modules allow the direct connection of thermocouple devices to the PLC.
Positioning Modules ■ Positioning modules ■ AD75P1-S3, AD75P2-S3, AD75P3-S3 AD75M1, AD75M2, AD75M3 Positioning modules The AD75 Series of modules represents the combination of Mitsubishi’s technological expertise in the manufacture and design of CNC, Inverter, Servo and PLC systems. These modules provide a plethora of functions which satisfy the requirements of even the most demanding of positioning applications.
Positioning Modules ■ Specifications AD75P1-S3 AD75M1 Item Number of input/output points used Number of control axis Interpolating function Control method Control unit Language Positioning pattern Program Setting device Backup m o Positioning method c . ic Position command range Positioning Accel./ decel. operation s n a y Sudden stop decel. time Start-up time Electronic gear Compensation Backlash compensation Error compensation func.
Positioning Modules ■ AD71 Positioning modules; pulse train output The AD71 is a pulse train output type positioning module with linear interpolation. It is suitable for use with both pulse and servo motors. High speed positioning is attainable over a wide positioning range. In addition the positioning control unit can be set in accordance with the application; i.e. pulse, mm. inch, and degrees. Compensation functions are also available for improving positioning accuracy. m o ■ AD71 specifications c .
Positioning Modules ■ AD70, AD70D, AD72 Positioning modules High speed positioning is attainable over a wide positioning range. In addition the positioning control unit can be set in accordance with the application; i.e. pulse, mm. inch, and degrees. Compensation functions are also available for improving positioning accuracy. AD72 is a voltage output type positioning module. It can be used in conjunction with a servo motor for closed loop control precision positioning applications.
High Speed Counter Modules ■ AD61 (S1) High speed counter module The high speed counter modules are designed to accept input pulses at frequencies up to 50 kHz. Count input pulses with rise and fall times of as little as 500 µs can be counted. The modules have a wide counting range: from 0 to 16,777,215. The counter can be preset or disabled by external signals, as well as from the sequence program in the host PLC CPU. Other features such as a ring counter function and external outputs are also available.
Ultrasonic Linear Scale Interface Module ■ A64BTL ultrasonic linear scale interface A64BTL is an interface module for connecting an ultrasonic linear scale manufactured by Balluf. Use of this linear scale gives the following advantages: ● Sealed construction so that it can be located in fluid. ● No accuracy degrading by friction ■ A64BTL specifications c .
Intelligent Communication Module ■ AD51H-S3, High speed intelligent (BASIC) communication module The AD51H-S3 is a high speed intelligent communications module capable of supporting up to four communications ports, 2 × RS232C, 1 × RS422, and 1 × parallel. It has an internal memory of 384k bytes for the storage of programs written in BASIC. These programs can be transferred to the module either by using an A6GPP/PHP or by using a VT220 compatible terminal.
Parallel Interface Module ■ AD59 Parallel interface module The AD59 parallel interface module allows the storing and printing out of large amounts of data. Data can be stored and accessed using the modules memory card interface, which allows a maximum of 32k bytes of data to be stored per memory card. This data can then be printed out via the modules built-in parallel interface. m o ■ AD59 specifications c .
Interrupt Module ■ AI61, High speed interrupt input module The AI61 is a high speed interrupt input module suitable for machine control applications which require rapid response times. When an interruption input signal is provided, the AI61 temporarily stops the normal sequence program from running and executes an interruption program according to the interruption vector. The interruption start condition may be selected by the use of internal switches according to the type of equipment connected; i.e.
System Monitor Modules ■ AS91 system monitor module The AS91 is a system monitor module which is loaded in an I/O slot of an QnA/A Series base unit. These modules monitor the I/O bus by inserting a fixed sequence program in front of the user program to monitor specific Y outputs. When using these modules, outputs are possible from an I/O bus error contact, a RUN contact and general purpose contacts. A 5 VDC check is also performed.
MELSECNET/10 MELSECNET/10 is a high speed network system offering higher performance than the MELSECNET II network system. MELSECNET/10 Fiber optic system m o c . ic MELSECNET/10 Coaxial cable system r t c e l E 32 stations ■ Up to 10/20M bps transmission speed ■ Extended network devices Computer supported flexible manufacturing requires more and more data flow on the factory floor.
MELSECNET/10 MELSECNET/10 for QnA ■ Extended network devices QSI200/250 fiber optic loop system GI50/125 fiber optic loop system GI62.
MELSECNET/II•B MELSECNET II, MELSECNET/B ■ A high speed, high reliablity data link system MELSECNET II m o c . ic MELSECNET/B r t c e l E s n ■ Choice of cable The MELSECNET system offers a choice of four different varieties of cable. These range from the low cost twisted pair cable bus to dual coaxial cable to the highly reliable GI dual fiber optic cable network. MELSECNET/B refers to the twisted pair cable bus system, while MELSECNET II to both coaxial and fiber optic systems.
MELSECNET/II•B ■ AJ71AP21, AJ71AR21, AJ71AT21B MELSECNET interface module The MELSECNET interface module allows the host PLC CPU to be connected on to the MELSECNET data link system. The module allows the PLC CPU to act as a master or local station on the network, as defined by the switch setting on the module. There are two interface modules, one for fiber optic cable networks and the other for coaxial cable networks. A maximum of one module can be used per PLC CPU.
CC-Link ■ Easy connection of bit level devices combined with advanced message and data transmission is now a reality with CC-Link, a field network system giving more sophisticated field information control while reducing cabling costs. MELSECNET/10 Master PLC Local PLC CC-Link, 10M bps Digital I/O Analog I/O High speed counter positioning etc.
CC-Link ■ Specifications: Network Item Specifications Transmission speed 156k/625k/2.
CC-Link Digital I/O Modules ● Input, output or input/output combined modules ● 16 pt terminal block, or 32 point high density connector ● 2-piece terminal construction for on-line I/O replacement ● 1 common per 2 I/O points type available Small Sized Digital I/O Modules ● DIN Rail mountable ● Can be horizontally or vertically mounted ● Space saving small size ● One touch connector reduces wiring work ■ Specifications: Remote digital I/O Input Model Type AJ65BTB1-16D AJ65BTB2-16D Point DC input Sink
CC-Link ■ Specifications: Small sized remote digital I/O Input Modules Model Type AJ65SBTC1-32D AJ65SBTB3-8D 32 8 AJ65SBTB3-16D 16 AJ65SBTB1-8D 8 AJ65SBTB1-16D AJ65SBTB1-16D1 AJ65SBTB1-32D DC sink/ source AJ65SBTB1-32D1 AJ65SBTC1-32D1 AJ65SBTC4-16D AJ65SBTW4-16D AJ65SBTB2-8A AJ65SBTB2-16A 16 8 16 AC 8 16 Type Output Modules Tr. Output sink 0.1A 0.5A Points per Number of common stations One touch 32 8 16 1.5ms Terminal block 8 16 3 6 0.2ms 15 3 0.2ms One touch 32 14 6 1.
CC-Link AJ65BT-64AD, AJ65BT-64DAV AJ65BT-64DAI Analog I/O Modules ● 12 bit resolution ● A/D conversion or D/A conversion modules ● 4 channel per module AJ65BT-68TD, AJ65BT-64RD3 AJ65BT-64RD4 Thermocouple and RTD Modules ● Isolation between channels (TD only) ● Wire breakage detection ● 8 channel per module (TD only) ● 4 channel per module (RD only) m o c .
CC-Link AJ65SBT-64AD Analog to Digital Conversion Module ● Four analog input (voltage input/current input) channels are provided. ● Greater accuracy and higher resolution than the AJ65BT-64AD has been realized. ● Separate analog input ranges can be set for each channel. ● By incorporating a movement averaging process, the averaging process can be carried out without changing the conversion speed. ● The installation area is 60% smaller and the volume is 38% smaller than the AJ65BT-64AD.
CC-Link AJ65BT-D62, AJ65BT-D62D AJ65BT-D62D-S1 Remote High Speed Counter ● Up to 400kpps counting (differential type) ● Two coincident outputs per channel ● Four special counting functions Ring counter, latch counter, periodic pulse counter, count disable AJ65BT-D75P2-S2 Remote Positioning Module ● 2 axes positioning control with linear or circular interpolation ● Pulse train output for either stepper or servo amplifier ● 32 bit positioning range ● Up to 1Mpps positioning speed (differential output type)
CC-Link AJ65BT-R2 Remote RS232C Interface Any RS232C equipped devices such as bar code reader or weighing meter, etc. can be connected to CC-Link through this RS232C interface module. Because of the high performance of CC-Link system, those RS232C devices can be located far away from PLC while retaining quick data access time. AJ65BT-G4 Remote Programming Interface This is a programming interface that may be located anywhere in the CC-Link system.
MELSECNET/MINI-S3 ■ AJ71PT32-S3 /AJ71T32-S3 MELSECNET/MINI-S3 master module The AJ71PT32-S3 /AJ71T32-S3 MELSECNET/MINI-S3 master module allows the host QnA/A Series PLC to control up to 64 remote I/O stations connected on the MELSECNET/ MINI-S3 networking system. The master module carries out high speed communication processing with the remote units connected to the network it controls. More than one master module can be used per PLC CPU, up to the maximum I/O points of the host CPU.
MELSECNET/MINI-S3 ■ Input Unit Specifications Operating voltage Class Model Outside the panel remote I/O No. of input points Input type AJ35PJ-8D AJ35TJ-8D DC (Sink type) Insulation 8 Input response time Rated input voltage Input current DC12/24V Input display ON voltage OFF voltage Over 9.5V 6V or less 4/10mA OFF ON ON OFF AJ35PTF-32A AC AJ35PTF-32D DC (Sink type) AC100V 10mA Over 80V 40V or less 15ms or less 20ms or less DC12/24V 3/7mA Over 9.
MELSECNET I/O LINK ■ I/O LINK High speed micro area distribution system m o c . ic r t c e l E s n ■ No additional program MELSEC-I/O LINK doesn't require any additional knowledge of programming or network parameter configuration. It works just like a standard I/O module programmed with input (X) and output (Y), but actual I/O signals are distributed to remote I/O modules.
MELSECNET I/O LINK ■ Flexible configuration Numbers of I/O points of the remote I/O modules are kept small so that just the necessary number of I/O signals are distributed to locations where control devices are located. In addition, no terminal resistance requirement and the T shape branch feature give maximum flexibility of configuration and layout. ■ High reliability Bus topology of MELSEC-I/O LINK gives the advantage of high reliability.
QnA Series Ethernet Modules ■ Ethernet modules AJ71QE71, AJ71QE71-B5 Features ● Operates on either of 10BASE5 or 10BASE2. ● TCP/IP, UDP/IP protocol support ● Selection of three communication modes Fixed buffer communication Random buffer communication PLC server function ● UDP/IP broadcasting ● PING function ● Connection through routers m o ■ Fixed buffer communication ■ PING function c .
A Series Ethernet Interface Modules ■ AJ71E71-S3 Ethernet module The AJ71E71-S3 is an ethernet network interface module which allows the host PLC CPU to be directly connected to an ethernet network system. It supports TCP/IP and UDP/IP protocols with the possibility of using either ethernet 10 BASE5 or 10 BASE2 simply by switch selection. The interface conforms with IEEE standard 802.3 (CSMA/CD) and features transmission speeds of up to 10M bps.
QnA Series Communication Modules ■ Serial Communication modules AJ71QC24N, AJ71QC24N-R2, AJ71QC24N-R4 Features ● A total of two channels of RS232C, RS422 and RS422/485 communication interface ports ● Both ports can operate as linked or independently. ● Choice of Dedicated protocol mode, Non-protocol mode, or Bi-directional protocol mode ● Entire QnA device memory area and program area can be accessed with the dedicated protocol mode. ● User definable frame is automatically added to transmission data.
A Series Communication Modules ■ Special communication modules m o ■ A computer interface module for linking to computers and other intelligent devices The AJ71UC24 computer interface modules allow external intelligent devices such as computers, to communicate with the PLC CPU. Sequence programs, bit devices, word devices, parameters etc. can be monitored or written to using serial communications which conform to RS232C and RS422 standards.
PROFIBUS Interface Modules ■ PROFIBUS DP/FMS, AJ71PB92D and AJ71PB96F ● Independent screen resolution AJ71PB92D and AJ71PB96F modules allow connection to PROFIBUS DP and FMS network respectively. Now A Series PLC’s can be used in conjunction with other PROFIBUS compatible equipment to provide a standard open network architecture while maintaining all the advantages and ease of use of the A Series.
DEVICENET Interface Modules AJ71DN91 DeviceNet Master Module The AJ71DN91 module allows connection to a DeviceNet system. This unit functions as a DeviceNet master and can control up to 63 slave stations over a distance of up to 500m. ● Selectable communication speed ● Recognized open network standard ● Wide range of DeviceNet compatible devices available m o Communication specifications ■ AJ71DN91 specifications Item By node type Settable station numbers Max.
MODBUS Interface Modules ■ AJ71UC24-S2 MODBUS interface modules The AJ71UC24-S2 modules allow the QnA/A Series PLC to be connected to the MODBUS network. These modules under a MODBUS network system act as a slave station to write and read data to/from the ACPU memory in accordance with instructions given from a master system. In addition to the MODBUS protocol, these modules also support extended functions equivalent to the dedicated protocols of standard AJ71UC24 modules.
PC Option Boards ■ Overview The A70BDE and A80BDE option boards are for use with an ® IBM AT or 100% compatible computer. The option boards perform a variety of functions, including functioning as a CPU board (A80BDE-A2USH-S1) which performs the same role as an A2USH-S1 CPU, functioning as a network board (A70BDEJ71QLP23, etc.), which turns the computer into a regular station of MELSECNET/10, and functioning as a CC-Link board (A80BDE-J61BT11, etc.), which connects the computer to the CC-Link system.
Programming Units ■ A7PU handy programming units The A7PU is a powerful, small programming device which can be used to compile, monitor and edit programs. It is a handy programming unit which can be used as either a hand held unit or as an interface unit for the programming of all the MELSEC A PLCs. It is capable of displaying two lines of program at a time and is connected to the PLC via an RS422 interface. When used in conjunction with an audio cassette, it can store and maintain programs and data.
Modem Interface Modules Q6TEL Features ● The QnA /A switch allows for connection to all QnA Series and A Series sequencer CPUs. ● Sequencer maintenance via remote access GPP peripheral devices such as DOS/V personal computers can be connected with the sequencer via a phone line allowing monitoring, testing, programming, and other revisions to be conducted at long distances. GPP peripheral devices such as DOS/V computers, and the sequencer when connected by RS-422 operate with the same GPP function.
Programming Software GX Developer (SW MD5C-GPPW-E) MELSEC Programming software ment is easy to use and new program development is both fast and efficient. GX Developer supports programming of all current MELSEC PLC CPUs, so project design using a variety of CPU types and series is possible. GX Developer is a powerful Windows based programming software which replaces the previous DOS version MELSEC MEDOC, GPPA and GPPQ software packages. However, GX Developer is more than just an upgrade.
Programming Software GX Converter (SW MD5C-CNVW-E) MELSEC Data conversion software With this data conversion software package, comments created in CSV format (Text data/Excel data (CSV format data) compatible), etc., can be used. By using this data conversion software package, the command lists from the “read/write of other formats” menu can be used for device comment data. Furthermore, the GX Developer command lists and device comments can be converted and used in the list created by the user.
Programming Software ■ MELSEC MEDOC plus, IEC compatible programming software MELSEC MEDOC plus is the programming software for all MELSEC series PLCs. This software has been developed to improve productivity of programming by incorporation of IEC61131 standards. The requirements to PLC controlled machinery and equipment are becoming more sophisticated. Also, PLC programs are becoming larger and more complicated. This results in a longer time required for PLC programming.
Human Machine Interface ■ GOT-900 series common features ● High speed response ● OS can be installed into GOT from a computer making it easy to upgrade versions and performance. GOT can be directly connected to the base of Mitsubishi PLC’s base which keeps transmission at very high speeds. (It can also be connected to the base of the PLCs of some other manufacturers.) ● Simulation function Through utilizing GT works, simulation from design graphics to debugging in a computer has been made possible.
Standards and Dimensions ■ Foreign Safety Standards Beginning with UL Certification, we have met the safety standards of numerous regulatory agencies. Standard Type of Certification Products Covered UL UL508 (America) A GOT cUL CSA (Canada) A GOT CE LVD, EMC (Europe) QnA A GOT Lloyd’s Register LR Ship Classification Certification QnA A DNV Norway’s Ship Classification Certification A NK Japan’s Ship Classification Certification c .
Dimensions ■ A37RHB ■ A68RB units: mm (inch) 4-ø6 screw hole 4-ø6 screw hole OUT 200 250 200 250 IN 477 497 477 497 29 11.6 11.6 9 9 29 ■ AnU, AnA and AnN r t c 439 (17.28) e l E 460 (18.11) 480 (18.90) m o 9 (0.35) c . ic 250 (9.84) 200 (7.87) 121 (4.76) 130 (5.12) 140 (5.51) 175 (6.89) s n a y ■ MELSEC-I/O LINK remote I/O module R Two ø4.5 mounting holes 66 (2.60) 114 (4.49) 105 (4.13) 45 (1.77) 50 (1.
Product Listing Type QnACPU ACPU Compatibility Model Specifications Q2ACPU Q2ACPU-S1 Q3ACPU Q4ACPU Q4ARCPU A38HB A38HBEU AJ71QC24 AJ71QC24N AJ71QC24-R2 AJ71QC24N-R2 AJ71QC24-R4 AJ71QC24N-R4 AJ71QLP21 AJ71QLP21S AJ71QLP21GE AJ71QBR11 AJ71QLR21 AJ72QLP25 AJ72QLP25G AJ72QBR15 AJ72QLR25 AJ71QE71 AJ71QE71-B5 AJ61QBT11 Q6PU Q6TEL Q1MEM-64S Q1MEM-128S Q1MEM-256S Q1MEM-512S Q1MEM-1MS Q1MEM-2MS Q1MEM-64SE Q1MEM-128SE Q1MEM-256SE Q1MEM-512SE Q1MEM-1MSE Q1MEM-256SF Q1MEM-512SF Q1MEM-1MSF Q1MEM-2MSF Q4ARCPU A61RP A
Product Listing Type Model Specifications A2ACPU A2ACPUP21 A2ACPUR21 A3NCPU A3NCPUP21 A3NCPUR21 A2NCPU-S1 ACPU modules A2NCPUP21-S1 A2NCPUR21-S1 A2NCPU A2NCPUP21 A2NCPUR21 A1NCPU A1NCPUP21 A1NCPUR21 A32B-E Main base A35B-E A38B-E A62B A65B A68B Extension base units A52B A55B A58B A3NMCA-0 A3NMCA-2 A3NMCA-4 A3NMCA-8 A3NMCA-16 A3NMCA-24 Memory modules A3NMCA-40 A3NMCA-56 A3AMCA-96 A4UMCA-128 A4UMCA-8E A4UMCA-32E A4UMCA-128E IC-RAM memory 4KRAM 4KROM EP-ROM memory 8KROM 16KROM E2PROM memory 4KEROM 16KHROM
Product Listing Type Model Specifications AC/DC input modules AX31 AX31-S1 AX40 AX41 AX41-S1 AX42 AX42-S1 AX70 AX71 AX80 AX80E AX81 AX81B AX81-S1 AX81-S2 AX82 AX50-S1 AX60-S1 AX11EU AX21EU AY10 AY10A AY11 AY11A AY11AEU AY11E AY11EEU AY13 AY13E AY13EU AY15EU AY20EU AY22 AY23 AY40 AY40A AY40P AY41 AY41P AY42 AY42-S4 AY50 AY51 AY51-S1 AY60 AY60E AY60EP AY60S AY70 AY71 AY72 AY80 AY80EP AY81 AY81EP AY82EP A42XY AG60 AG62 AI61 A68AD A68AD-S2 A68ADN 32 points, AC 24V or DC 24V 32 points, DC24V 16 points, DC1
Product Listing Type A/D conversion modules D/A conversion modules High speed counter modules Positioning modules Positioning training modules Positioning Detection Unit Ultrasonic linear scale interface unit Model Specifications A616AD A60MX A60MXR A60MXT A616TD AC12MX A68RD3 A68RD4 A68DAV A68DAI-S1 A62DA A62DA-S1 A616DAV A616DAI A68P AD61 AD61-S1 AD75M1 AD75M2 AD75M3 AD75P1-S3 AD75P2-S3 AD75P3-S3 AD778M AD70 AD70D AD71 AD71-S1 AD71-S2 AD71-S7 AD72 AD75TU AD71TU A61LS A62LS-S5 A63LS 0-20mA or 0 t
Product Listing Type MELSECNET/10 modules MELSECNET/10 repeater MELSECNET/10 repeater MELSECNET/10 resistance Coaxial type MELSECNET II Ethernet interface module MELSECNET/MINI-S3 Specifications AJ71BR11 AJ71LR21 AJ72LP25 AJ72LP25G AJ72LP25GE AJ72BR15 AJ72LR25 A6BR10 A6BR10-DC A6RCON-R75 MELSECNET/10 master/local, coaxial MELSECNET/10 master/local, coaxial MELSECNET/10 remote I/O controller, fiber optic MELSECNET/10 remote I/O controller, fiber optic GI MELSECNET/10 remote I/O controller, fiber optic
Product Listing Type Converters Others for MELSECNET/MINI-S3 MELSEC I/O Link I/O LINK master DC input units DC input units Transistor output units Relay output units DC input/transistor output units DC input/relay output units Specifications AJ35PTC-CNV-GI AJ35PP-CNV AJ35PP-CNV-SI AJ35PTF-R2 AJ35PT-OPB-M1-S3 AJ35PT-OPB-P1-S3 AJ35T-JB-S3 AJ35T-JBR-S3 AC30 MINI Twisted pair/GI fiber optic converter Plastic fiber optic/plastic fiber optic converter Plastic fiber optic/SI fiber optic converter RS232C
Product Listing Model Specifications Compact output units AJ65SBTB2-8R AJ65SBTB2-16R AJ65SBTB2N-8R AJ65SBTB2N-16R AJ65SBTB2-8S AJ65SBTB2-16S AJ65SBTB2N-8S AJ65SBTB2N-16S 8 points DC24V/AC240V (2A) relay output, 1-wire, terminal type 16 points DC24V/AC240V (2A) relay output, 1-wire, terminal type 8 points DC24V/AC240V (2A) relay output, 2-wire, terminal type 16 points DC24V/AC240V (2A) relay output, 2-wire, terminal type 8 points AC100-240V (0.
Product Listing Type QnACPU ACPU Compatibility Model Specifications AJ65SBT-RPS SI/QSI type for use with fiber optic cable (2 units can be used together), for 156k/625k/2.5M/ 5M/10Mbps, maximum transmission distance: 500m(SI), 1000m (QSI), maximum number of connection steps: 2 ✓ ✓ AJ65SBT-RPG GI type for use with fiber optic cable (2 units can be used together), for 156k/625k/2.
m o c . ic r t c e l E s n a y R L-174-0-C5177-A NA-0010 Printed in Japan (BUN) New publication, effective Oct. 2000 Specifications subject to change without notice.