Endeavor 5 - 10KVA Step Down Transformer User's Manual Para Systems, Inc. 1455 Lemay Dr. Carrollton, TX 75007 Phone: 1-972-446-7363 Fax: 1-972-446-9011 Internet: minutemanups.com UPS Sizing: sizemyups.
Table Of Contents 1. Introduction 2 2. Rear Panels 6 3. Installation 8 4. Operation 14 5. Obtaining Service 16 6. Specifications 17 7. Limited Product Warranty 18 A1.
Chapter 1: Introduction Thank you for purchasing this power protection product. It has been designed and manufactured to provide many years of trouble free service.
CAUTION! To de-energize the outputs of the ED-XFR: 1. Turn off the Load breakers on the rear panel of the ED-XFR. 2. If the UPS is on press and release the On/Off/Test button after the second beep. 2. Turn off the input circuit breaker on the rear panel of the UPS. 3. Turn off the DC breaker on the rear panel of the Battery Pack. 4. Disconnect the UPS from the AC source.
Chapter 2: Rear Panels 1. The Load 4 circuit breaker will trip in the event the load exceeds the power rating. 2. Load 4: 120V output receptacles (3 - 5-15/20R). 3. The Load 3 circuit breaker will trip in the event the load exceeds the power rating. 4. Load 3: 120V output receptacles (3 - 5-15/20R). 5. The Load 2 circuit breaker will trip in the event the load exceeds the power rating. 6. Load 2: 208V output receptacle (1 - L6-20R). NOTE: The default output voltage is 208V.
Chapter 3: Installation INSTALLATION PLACEMENT This ED-XFR series is ONLY intended to be installed in an indoor temperature controlled environment that is free of conductive contaminants. DO NOT operate the unit in: extremely dusty and/or unclean areas, locations near heating devices, water or excessive humidity, or where the unit is exposed to direct sunlight. Select a location, which will provide good air circulation for the unit at all times. Route power cords so they cannot be walked on or damaged.
TOWER CONFIGURATION The tower configuration allows the user to install the ED-XFR in the up-right position. The tower stands are provided with the UPS. The tower stand extenders are provided with the ED-XFR. WARNING: Use two or more people when installing the ED-XFR. USE CAUTION: The ED-XFR is extremely heavy. Use the appropriate number of personnel when installing the UPS system. 1. Once the location of the ED-XFR has been determined, place the tower stands in the desired location.
The ED8000RT-XFR and ED10000RT-XFR come with an #6 AWG input power cable in the box. The pins for the input cable are included. Connect one end of the input power cable to the input terminal block on the ED-XFR. Connect the other end of the input power cable to the output terminal block on the UPS. The AC inputs of these Step Down Transformers are ONLY intended to be connected to the output of their respective UPS models. Do not use extension cords, adapter plugs, or surge strips.
c) 2. 3. 4. 5. Connect the green wire labeled G on the input power cable to the EDXFR AC input terminal block ground terminal and secure. Connect the other end of the #6 AWG input power cable labeled "TO UPS" to the output terminal block on the UPS and secure. a) Connect the black wire labeled L on the input power cable to the UPS output terminal block labeled L and secure. b) Connect the white wire labeled N on the input power cable to the UPS output terminal block labeled N and secure.
Chapter 5: Obtaining Service IF THE STEP DOWN TRANSFORMER REQUIRES SERVICE 1. Use the Troubleshooting section in the UPS user's manual to eliminate obvious causes. 2. Verify there are no tripped circuit breakers. A tripped circuit breaker is the most common issue. 3. Call your dealer for assistance.
Chapter 7: Limited Product Warranty Para Systems, Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period of three years from the date of purchase. For equipment sites within the United States and Canada, this warranty covers depot repair or replacement of defective equipment at the discretion of Para Systems. Depot repair will be from the nearest authorized service center.