User Manual Part 1

64
Cleaning and Disinfection
G1
US
11 Cleaning and Disinfection
Depending on the cleaning policy adopted, either a designated person or the user should clean each
device after each use. ANSI standards suggest that users should be trained in the cleaning procedure.
Confidence Plus
®
Cleaning Solution (P/N 10009971) from MSA is recommended. It cleans and disin-
fects in one operation. It retains its germicidal efficiency in hard water to inhibit the growth of bacteria.
It will not deteriorate rubber, plastic, glass, or metal parts. Refer to the label for user instructions.
If the SCBA is soiled (i.e. heavy smoke residue or dirt accumulation) use a sponge damp with mild
soap solution or use a soft/medium bristle brush to remove deposits that may interfere with normal
operation of:
- Harness (straps and buckles)
- Carrier (band and latch assembly)
- Cylinder (handwheel, gauge, outlet connection)
- Pressure reducer (bell and coupling nut connection)
- Control module/power module/battery module/speaker module
Inspect the entire SCBA as it is reassembled. Follow the Inspection Instructions.
Preparing Solution
Follow the instructions with the Confidence Plus
®
Cleaning Solution.
If the Confidence Plus Cleaning Solution is not used, wash in a mild cleaning solution, rinse thor-
oughly, and submerge in a germicide solution for the manufacturer's recommended time.
WARNING
- DO NOT use any cleaning substances that can or might attack any part of the SCBA.
- DO NOT use alcohol because it may deteriorate rubber parts.
- If not rinsed thoroughly, cleaning agent residue may irritate the wearer's skin.
Failure to follow these warnings can result in serious injury or death.