OPERATOR'S MANUAL Cat. No. M18 HUP700R M18™ FORCE LOGIC™ 10,000 PSI HYDRAULIC PUMP WARNING To reduce the risk of injury, user must read and understand operator's manual.
•Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury. •Do not overreach. Keep proper footing and balance at all times. This enables better control of the power tool in unexpected situations. •Dress properly. Do not wear loose clothing or jewelry. Keep your hair and clothing away from moving parts. Loose clothes, jewelry or long hair can be caught in moving parts.
•When battery pack is not in use, keep it away • reduce the risk of arc WARNING To flash,electric shock and from other metal objects, like paper clips, coins, property damage, work on de-energized keys, nails, screws or other small metal objects, that can make a connection from one terminal lines when possible. Tool is not insulated. to another.
FUNCTIONAL DESCRIPTION 1 10 12 2 13 14 11 5 3 15 16 4 6 17 9 24 7 18 8 19 20 21 Cat. No. .......................................... M18 HUP700R Volts.......................................................... 18 V DC Battery Type .................................................M18™ Charger Type................................................M18™ Operating Pressure ...............................10,000 psi max. (700 bar max.) Ingress Protection............................................
Priming the Hydraulic System use accessories WARNING Only recommended for this tool. Others The tool should be primed any time that it has run dry of oil. may be hazardous. To prime the system: Removing the Vent Plug Before using the tool, ensure the vent plug is re- 1. Remove the battery pack. 2. Inspect the oil sight line and ensure the tool has moved. enough oil. To remove the vent plug: 3. Connect the coupler to an accessory head that will siphon out the air and excess oil.
Selecting Mode 6. Press and hold the advance button on the remote. ONE-KEY™ 7. If in auto-dump mode , the pump will release pressure as soon as 10,000 psi is reached. The pump features three modes of operation: Auto-Dump mode unloads pump pressure as soon as 10,000 psi is reached. Hold Pressure mode holds pressure until the manual release button is pushed or the retract button is pushed on the remote. Wireless mode allows the user to activate the pump via bluetooth signal.
6. Press the wireless mode button on the pump. Light Indicator Solid Green Tool reached full pressure. red. Solid Red 7. On the remote, turn the wireless power switch on . Tool did not reach full pressure. NOTE: If the indicator shows red, check the oil levels and ensure that no leaks are happening in the at-tachments. Confirm that all connections are secure and the attachments are proper for the job. Repeat the steps under “Operation”.
NOTE: AAA batteries are not required while connected to the pump. To replace the batteries: 1. Remove the battery door screws on the back of the remote. Remove battery door. 2. Insert four AAA batteries according to the polarity marked in the battery compartment. 3. Close the battery door and reinsert the screws, tightening securely. To reduce the risk of personal inWARNING jury and damage, never immerse your tool, battery pack or charger in liquid or ONE-KEY™ Burn Hazard.