MILBANK MANUAL TRANSFER SWITCH 30 & 50 AMP OWNER’S & INSTALLATION MANUAL MODEL # MMTS301SYS MMTS301 MMTS501SYS MMTS501 Revision 1.1 BOM # 1171740 3.26.15 Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.
California Proposition 65 Warning Certain components in this product and its related accessories contain chemicals known to the state of California to cause cancer, birth defects or other reproductive harm. Wash hands after handling. DISCLAIMERS: All information, illustrations and specifications in this manual are based on the latest information available at the time of publishing. The illustrations used in this manual are intended as representative reference views only.
TABLE OF CONTENTS INTRODUCTION................................................................................................................. 4 CONTACT INFORMATION......................................................................................................................4 MANUAL TRANSFER SWITCHTM...........................................................................................................5 GENERATOR.....................................................................................
INTRODUCTION Thank you for your purchase of a Milbank Manual Transfer Switch (MMTS). This product is designed for use with portable generators. This Manual Transfer Switch may have different installation requirements depending on the generator manufacturer or design. When operated and maintained according to the instructions in this manual, your system will provide many years of electrical energy service for utility outages.
INTRODUCTION For your future reference please record the following pertinent information. This information will help to identify product information should you need to contact Milbank’s Technical Services department.
SAFETY IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. • This manual contains important information that should be used during installation, maintenance and operation of this unit. SAFETY LABELS ! WARNING Only qualified electricians should attempt installation of this equipment, which must strictly comply with all applicable codes, standards and regulations.
SÉCURITÉ IMPORTANT SAFETY INSTRUCTIONS CONSERVER CES INSTRUCTIONS • Ce manuel contient des informations importantes qui doivent être utilisés lors de l’installation, l’entretien et le fonctionnement de cet appareil. SÉCURITÉ SYMBOLE SIGNIFICATION ! AVERTISSMENT Seuls des électriciens qualifiés devraient tenter l’installation de cet équipement, qui doit se conformer strictement aux codes, aux normes et réglementations.
SAFETY WARNING Failure to properly ground equipment can result in electrocution. • Do not touch bare wires. • D o not use equipment with worn, frayed, bare or otherwise damaged wiring. • D o not handle electrical cords while standing in water, while barefoot, or while hands or feet are wet. • I f you must work around a unit while it is operating, stand on an insulated dry surface to reduce shock hazard. • Do not allow unqualified persons or children to service equipment.
SÉCURITÉ AVERTISSMENT Un défaut de terre le matériel peut entraîner une électrocution. • Ne pas toucher les fils nus. • Ne pas utiliser de matériel avec des cordons électriques usés, effilochés ou dénudés, ou autrement endommagé. • Ne pas manipuler les fils électriques tout en restant dans l’eau, pieds nus ou avec les mains ou les pieds mouillés. • Si vous devez travailler autour d’une unité pendant son fonctionnement, tenir sur une surface sèche isolée pour réduire les risques de choc.
PACKAGE CONTENTS Before installation, please refer to the following chart to ensure you have received the appropriate components for your model of Manual Transfer Switch.
OPERATION & INSTALLATION Utilizing a portable generator, your Manual Transfer Switch will power to selected circuits in the event that utility power is interrupted. The MMTS normal operation is to connect the Utility to the selected circuits using the internal Load Subpanel. The MMTS system can manually switch up to 8 AC circuits when operating on generator power.
OPERATION & INSTALLATION ! The installation of the MMTS shall conform to national and local electrical codes and should only be performed by a licensed electrician. Each installation of a manual transfer switch is unique and as such it is not possible for this manual to cover every configuration and procedure necessary to complete the installation; neither can potential hazards and/or the result of each method or procedure be anticipated in this manual. See Figure 2 for a typical install.
OPERATION & INSTALLATION FUNCTIONAL TESTING At the completion of the installation, test for proper operation; 1. Attach the portable generator to the MMTS through the inlet. 2. Turn off all sub panel circuit breakers and the utility circuit breaker. 3. Start the backup Generator. • Turn on circuit breaker A2 and verify that the lower left and the upper right LED’s are illuminated. If the LED’s are not illuminated verify that the circuit has a load attached to the circuit.
MOUNTING DIMENSIONS Figure 3 – Mounting Dimensions 14 Milbank Manual Transfer Switch Owner’s and Installation Manual
SET UP The MMTS monitors power of the selected loads connected to the MMTS and displays the power output on each Phase using 8 LED’s for each Phase. After the MMTS is installed the breakers should be shut off before applying power to the MMTS. To test the unit turn on the Utility circuit breaker and turn on each load circuit breaker. Figure 4 show the MMTS circuit breakers set properly before turning on the generator.
SET UP Learn Function should be activated when on generator power to ensure that the generator can support the desired loads being controlled. The loads are should be turned on until desired generator capacity is reached. Additional loads, such as an electric heater, may be added during the Learn Mode process to force the generator to full capacity. To establish the capacity of the generator several methods may be used: 1.
SET UP NORMAL OPERATION As each circuit breaker is turned on the LED display should be examined to verify that the loads are balanced, within 2 LED’s illuminated on each side. The following figures show how the LEDs advance as the circuit breakers are turned on. Figure 6 – Only A2 “On A2 & B2 “On As each circuit breaker is turned on the LED display should be examined to verify that the loads are balanced, within 2 LED’s illuminated in each side.
TROUBLESHOOTING Problem Cause Correction No LED’s light on the control panel 1. All Circuit breakers are off 2. Utility is off and the Generator is not running or not connected 3. No load is on the circuits 1. Turn off the Circuit Breakers 2. Connect the Generator and turn on 3. Turn on loads on the circuits The LED’s are unbalanced 1. The Loads attached to the MMTS are on one phase 1. Rewire the MMTS load circuits to balance the loads Loads are not on when Utility is restored 1.
WARRANTY MILBANK MANUAL TRANSFER SWITCH OWNER WARRANTY POLICY LIMITED WARRANTY MILBANK MANUFACTURING WILL REPAIR OR REPLACE, FREE OF CHARGE, ANY PART(S) OF THE EQUIPMENT THAT IS DEFECTIVE IN MATERIAL OR WORKMANSHIP OR BOTH PROVIDING THAT INSTALLATION OF THE EQUIPMENT COMPLIES WITH ALL APPLICABLE CODES, INDUSTRY STANDARDS, LAWS, REGULATIONS AND PROVIDED INSTALLATION MANUAL. MANUAL TRANSFER SWITCH AND ASSOCIATED COMPONENTS SHALL BE INSTALLED ONLY BY A LICENSED ELECTRICIAN, AND OTHERWISE THIS WARRANTY IS VOID.
WARRANTY REPLACEMENT PARTS IDENTIFICATION For replacement parts please reference the Milbank part number shown; 301SYS / 501SYS DEAD FRONT 1 2 3 5 6 7 8 301 / 501 DEAD FRONT 5 15 14 4 13 9 10 11 1 12 MANUAL TRANSFER SWITCH REPLACEMENT PARTS ITEM 1 2 3 2 4 3 5 4 5 6 7 8 9 10 11 12 13 14 15 INLET BOX REPLACEMENT PARTS 30A INLET L14-30P 50A INLET CS6375 GROUND CONNECTOR 30A RATING LABEL 50A RATING LABEL COVER WARNING LABEL Z1170217 Z1169531 Z1002769 Z1169883 Z1169884 Z1170465 Z1168019
SPECIFICATIONS Model Number Breaker Amperage MMTS301SYS MMTS501SYS GEN UTIL GEN UTIL 30 60 50 100 Phase Single Limited Warranty 4 Years Circuits Amps Partial House, 8 circuit’s maximum 30 50 Service entrance disconnect YES Maximum Load Current YES Rated AC VoltageA 120 240 Poles 2 Frequency 60 Unit (Height x Width x Depth) 15.25” x 10.25” x 6.63” Shipping Carton 16.25” x 11.25” x 7.75” Weight Milbank Manual Transfer Switch Owner’s and Installation Manual 23 lbs.
The digital monitor on the Milbank Manual Transfer Switch is an added tool that QUICK START GUIDE enables the user to safely use their portable generator and reduce the chance of an overload condition. To effectively utilize this option we have included a learn function in the MTS that will allow you to calibrate the switch for the size of generator you are The digitalusing.
QUICK START GUIDE The digital monitor on the Milbank Manual Transfer Switch is an added tool that enables the user to safely use their portable generator and reduce the chance of an overload condition. To effectively utilize this option we have included a learn function in the MMTS that will allow you to calibrate the switch for the size of generator you are using. Until Generator is “Full” Learn Complete 150% Q: Sometimes the lights blink faster than other times.
MILBANK MANUAL TRANSFER SWITCH Revision 1.1 BOM # 1171740 3.26.15 Milbank | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.