MIL-4750 and MIL-4755 Master/Slave Modules User’s Guide with FastManage™-Specific Information Sunnyvale, California Minnetonka, Minnesota
LEGAL Trademark Rights © 2000 MiLAN, the MiLAN logo, and MiLAN Technology are either trademarks or registered trademarks of Digi International, Inc. in the United States and/or other countries. All other trademarks are the property of their respective holders. Information in this document is subject to change without notice and does not represent a commitment on the part of MiLAN Technology.
Table of Contents Preface About this Manual ................................................................... Master/Slave Documentation ....................................................... Contents of this Document ......................................................... Package Contents .................................................................... Notation Conventions ...............................................................
Appendix B: Technical Support Services World Wide Web Server ......................................................... Internet FTP Server ............................................................... Contacting Technical Support.................................................... Expediting Technical Support.................................................... RMA Procedures................................................................. B-1 B-1 B-1 B-1 B-1 B-2 Doc #:90000225 Rev.
P ref ac e P.1 About this Manual This guide covers both the MIL-4750 and the MIL-4755 Master/Slave modules. These modules were designed to be installed into MiLAN’s Media Conversion System. The terms “Master/Slave module” and “module” are used throughout this document to describe these devices. This manual assumes that you are familiar with the tasks of a system administrator. P.
Preface P.3 Contents of this Document • Chapter 1: Has an overview of the Master/Slave modules • Chapter 2: Provides instructions for installing the modules • Chapter 3: This section has information on FastManage for the MIL-4750 Master module P R E F A C E • Appendix A: Specifications information for both modules • Appendix B: Technical support information P.
Ch ap te r 1 : In tro d u c tio n Chapter 1 gives a description of the MIL-4750 and MIL-4755 Master/Slave modules. 1.1 Overview of the Master/Slave Modules 1.1.1 MIL-4750 Master Module The MIL-4750 Master module is designed to provide two-way communication between a host workstation and MiLAN’s media conversion modules. Communication between these devices is performed via the network link and SNMP management. The module uses auto-negotiation to perform in either 10/100 Mbps. Figure 1-1.
Chapter 1 1.2 Features One MIL-4750 Master module can support (in a daisy-chain configuration via the serial RS-422 interface) up to four MIL4755 Slave modules. Definition of daisy-chain: "out" port of 4750 to "in" port of 4755. Last 4755 "out" port to "in" port of 4750. I N T R O D U C T I O N 1.2.1 Common Features for Both Modules • Hot-swappable • Diagnostic LED(s) 1.2.
Ch ap te r 2 : In s ta lla tio n Chapter 2 gives installation information for the modules. 2.1 Installation Requirements Before installing a module, you will need the following (most items sold separately): • An MIL-9200X Media Conversion System • Ethernet cabling (CAT 5 for in-band management) • RS-232 Serial cabling (for out-of-band management) • Female DB9 connector to RJ45. 2.
Chapter 2 3. Slide the module into the slot through the guide rails. 4. Insert the module into the card-edge connector (port bay). Make sure it is seated firmly. 5. Secure the module with the two thumbscrews located on the faceplate of the unit. 6. Make all your network connections. I N S T A L L A T I O N Note: Do not plug a phone cable (RJ-11) into the RS-232 and/or RJ-45 connectors. 2.3 DIP Switch Settings On the front panel of the MIL-4750 module is a two-position DIP switch.
Ch ap t e r 3 : Fa s tMa n ag e fo r th e M edia Co nve rs io n S y s te m Chapter 3 discusses FastManage-specific software as it applies to the media conversion system, including the MIL-4750 Master module. This chapter does not have detailed FastManage instructions (refer to the FastManage User’s Guide section of the LAN Products CD-ROM). 3.1 Overview of FastManage FastManage configures and manages most SNMP-types of devices over the subnet; including print servers and stackable hubs.
Chapter 3 display its “stack” of device(s) (Figure 3-1). • Media Conversion System Mgr. Icon: a. Also start the software by double-clicking on the Media Conversion System Mgr. icon. b. Enter the IP Address of a specific device that you want to manage. c. A “stack” of SNMP managed device(s) appear. One to sixteen devices may be displayed (Figure 3-1). F A S T M A N A G E Figure 3-1. Stack Device Graphical Icon d. To launch a device in the stack, double-click on that particular unit.
Chapter 3 Figure 3-2. First Device of a Stack e. Double-click on a module to launch it. Figure 3-3 may appear (depending on the module selected). Note: MiLAN offers many different modules to configure, including the MIL-4750 (shown in Figure 3-3). All modules, except the MIL-4755 slave module, have hot spots where the user can gain information. Figure 3-3. MIL-4750 Master Module 3.3 Hot Spots and System Information Hot spots on the graphic are used to gain information on the device.
Chapter 3 MIL-9200X redundant rack mount chassis. For more information and detailed descriptions of these hot spots, refer to the FastManage User’s Guide section of the LAN Products CD-ROM. • Traps (Figure 3-1): This selection alerts the user to any problem associated with the device (e.g., a power failure). • System Information (Figure 3-1): This selection describes the device chosen, including its Location and Up Time.
Appendix A: Specifications A.1 Hardware Features for the MIL-4750 • CPU: An 80186 processor, with a 25 MHz clock • Memory: 256 RAM • Flash: Flash devices are 29F040 @ 90 ns. Each device is 4 Mbps and arranged in 2 × 256k × 8 format • MAC chipsets: Ethernet controller is 10/100 Mbps, with its own memory management • 10/100BASE-TX, RJ-45 (unshielded twisted pair) connector A.
Appendix A A.4 Connectors A.4.1 RS-232, RJ-45 Connector Use a standard null-modem for communication when connecting “straight-through” to a DB9 connector. PIN Number 1 2 3 4 5 S P E C I F I C A T I O N S Signal PIN Number NC RXD TXD DTR/RTS GND 6 7 8 9 (for DB9) Signal NC RTS/DTR CTS NC A.4.2 RJ-45 Pinouts 3 4 1 2 • Pin 1: Transmit data + 5 6 7 8 • Pin 2: Transmit data • Pin 3: Receive data + • Pin 6: Receive data Note: For a workstation/PC port, use a swap cable.
Appendix B: Technical Support Services B.1 World Wide Web Server Product information, manuals, new product announcements, programs, applications stories and more can be obtained through the world wide web. Our address is: http://www.milan.com B.2 Internet FTP Server MiLAN has set up an anonymous FTP server for those with access to the internet. The address is ftp.milan.com. Drivers and installation tips are located in the /pub/ rackmount directory. Note: B.
Appendix B disk space • Note any and all error messages • Be specific about the problem(s) B.5 RMA Procedures To return a unit to MiLAN for repair: 1. Call technical support at 408/744-2751 2. Technical support engineers will work with users to find the problem. If technical support determines that the unit is defective, a return materials authorization (RMA) will be issued by our RMA administrator who will also provide shipping instructions.
Index Numerics 10 Mbps A-1 10/100BASE-TX 1-2, A-1 100 Mbps A-1 25 MHz clock A-1 256 RAM A-1 29F040 A-1 80186 processor A-1 A About this manual P-1 C CAT 5 2-1 Configuration options 3-4 D Daisy-chain configuration 1-2 Device speed A-1 DIP switch settings 2-2 E Environmental operating conditions A-2 Ethernet A-1 F FastManage 3-1 FastManage User’s Guide 3-1, 3-4 Features 1-2 Flash device A-1 ftp.milan.com B-1 H Hardware features A-1 Hot spots 3-3 http:// www.milan.
Media conversion system mgr. 3-1 MIL-4750 P-1, 1-1, 2-2 MIL-4755 P-1, 1-1 N NetBIOS configuration 3-4 P Power supply A-6 R Return materials authorization (RMA) B-2 RJ-45 1-2 RS-232 serial 1-2, 2-1 S SNMP 3-1 Hardware features A-1 www.milan.com B-1 System LEDs A-1 T Technical support B-1 Traps 3-3 Doc #:90000225 Rev.
1299 Orleans Drive Sunnyvale, CA 94089 Part Number: 90000225 Rev.