Operating and Installation instructions
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Caring for the environment
- Saving energy
- Guide to the appliance
- Switching on and off
- The correct temperature
- Using SuperFrost
- Temperature and door alarm
- Selecting additional settings
- Freezing and storing food
- Adjusting the interior fittings
- Making ice cubes
- Automatic defrosting
- Cleaning and care
- Frequently Asked Questions
- Causes of noises
- Customer Service
- Information for dealers
- Installation
- Installation
- Installation dimensions
- Limiting the opening angle of the appliance door
- Changing the door hinges
- Building in the appliance
- Preparing the appliance
- With 5/8" (16 mm) thick cabinet walls only:
- Building in the appliance
- Securing the appliance in the niche
- Only for an appliance with a niche height greater than 55" (140 cm)
- Installing the cabinet door
- Adjusting the position of the door
- X: side adjustments
- Y: height adjustment
- Z: depth adjustment
- Water connection
- Electrical connection
Frequently Asked Questions
49
Problem Possible cause and solution
The compressor is turn-
ing on more frequently
and for longer periods
of time; the temperature
in the appliance is too
low.
The ventilation gaps in the cabinetry have been cov-
ered or become too dusty.
Do not block the ventilation gaps.
Clean the ventilation gaps on a regular basis to re-
move any dust.
The door has been opened too frequently, or a large
amount of fresh food has been placed inside and/or
frozen at the same time.
Only open the door when necessary and for as
short a time as possible.
After a while, the temperature will return to normal by
itself.
The appliance door is not properly closed.
A thick layer of ice may have already formed in the
freezer.
Close the appliance door.
After a while, the temperature will return to normal by
itself.
If a thick layer of ice has already formed, this will af-
fect cooling and increase energy consumption.
Defrost the appliance and clean it.
The ambient temperature is too high. The higher the
ambient temperature, the longer the compressor has
to run.
See the “Installation location” section in the “In-
stallation information”.
The appliance was not properly installed in the niche.
See the “Installation information” and “Building in
the appliance” sections.