Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr.
Contents IMPORTANT SAFETY INSTRUCTIONS ................................................................ 4 Caring for the environment ................................................................................ 13 Description of functions ..................................................................................... 14 Con@ctivity 2.0 function........................................................................................ 15 Guide to the appliance ..........................................
Contents Exhaust duct ........................................................................................................ 46 Condensate trap.................................................................................................... 47 Electrical connection .......................................................................................... 48 Grounding Instructions.......................................................................................... 48 Activating Con@ctivity 2.0 ....
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user. Use CAUTION: For General Ventilating Use Only.
IMPORTANT SAFETY INSTRUCTIONS Children As with any appliance, close supervision is necessary when used by children. Please supervise children in the vicinity of the hood and do not let them play with it. Danger of suffocation! Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children.
IMPORTANT SAFETY INSTRUCTIONS Be certain your appliance is properly installed and grounded by a qualified technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met. If there is any doubt, have the electrical system of the house checked by a qualified electrician.
IMPORTANT SAFETY INSTRUCTIONS During installation, maintenance, and repair work, the ventilation hood must be disconnected from the electrical supply. It is only completely isolated from the electricity supply if one of the following applies: – The circuit breakers on the electrical service panel are tripped. – The screw-type fuses on the electrical service panel have been removed. – The power cable (if present) has been unplugged from the socket (pull the plug not the cord).
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: – a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. – b) NEVER PICK UP A FLAMING PAN - You may be burned. – c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
IMPORTANT SAFETY INSTRUCTIONS Overheated oils and fats can ignite and set the ventilation hood on fire. When cooking with oils or fats, do not leave pots, pans or fryers unattended. Never leave an electric grill unattended when grilling. Fat and debris deposits impair the proper functioning of the ventilation hood. To ensure that cooking vapors are properly cleaned, never use the ventilation hood without the grease filters in place.
IMPORTANT SAFETY INSTRUCTIONS Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. – b) Sufficient air is needed for combustion and exhausting of gases through the flue (chimney of fuel burning equipment to prevent back drafting.
IMPORTANT SAFETY INSTRUCTIONS Be sure to observe the information contained in the "Installation" section when mounting the ventilation hood. Metal parts can have sharp edges which may cause injury. Wear gloves to protect your hands from being cut. When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service.
IMPORTANT SAFETY INSTRUCTIONS FCC Declaration of Conformity These devices comply with FCC Rules Part 15. This equipment has been tested and found to be in compliance with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules of Operation and is subject to the following conditions: These devices may not cause harmful interference. These devices must accept any interference received, including interference that may cause undesired operation.
Caring for the environment Disposal of the packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children. Danger of suffocation! Disposal of your old appliance Do not dispose of this appliance with your household waste. Old appliances may contain materials that can be recycled.
Description of functions The following functions are available on your ventilation hood, depending on the model: Vented mode The air is drawn in and cleaned by the grease filters and directed outside. Non-return flap A non-return flap in the ducting prevents the exchange of inside and outside air from occurring when the ventilation hood is not in use. The flap is closed when the ventilation hood is turned off.
Description of functions Con@ctivity 2.0 function Automatic control This hood features a communication function which enables the automatic control of the hood based on the operational status of a Miele induction cooktop. The cooktop transmits information about its operational status to the hood using a radio signal. – When a burner is turned on, the cooktop lighting on the hood turns on automatically. After a brief delay, the ventilation hood fan also comes on.
Guide to the appliance 16
Guide to the appliance a Chimney extension b Chimney c Canopy d Control panel The symbols act as sensor-controlled buttons. To select a function, tap the button. An audible tone sounds briefly to confirm selection. e Grease filter f Spacer frame The spacer frame creates a shadow gap between the chimney and the ceiling. The hood can be installed with or without the spacer frame.
Operation (Automatic mode) When Con@ctivity 2.0 is active, the hood always operates in Automatic mode (see "Activating Con@ctivity 2.0"). See "Cooking without Con@ctivity 2.0" for information on manually operating the hood. Cooking with Con@ctivity 2.0 (Automatic mode) Turn on a burner to the desired power setting. Overhead cooktop lighting. After a few seconds, the fan will come on, briefly operating at power level 2 before immediately switching to level 1.
Operation (Automatic mode) Cooking process Deactivation If, for example, you switch on a burner at the highest power setting to heat cookware in preparation for searing and then reduce the power level after approx. 60 to 90 seconds, a cooking process is recognized. Turn off all burners. The hood turns on automatically and, after the cooktop power level has been reduced, switches back to fan level 3, where it remains for approx. 5 minutes.
Operation (Automatic mode) Temporarily exiting Automatic mode To temporarily exit the Automatic mode when cooking: Manually select a different fan level, or Manually turn the hood off, or Activate the Delayed shut down function on the ventilation hood. The fan turns off after the delay time selected, and the lighting will remain on. The ventilation hood functions can now be operated manually (see "Cooking without Con@ctivity 2.0").
Operation (Manual mode) Cooking without Con@ctivity 2.0 (Manual mode) Selecting the delayed shut down time The hood can be operated manually if: It is a good idea to let the fan run for a few more minutes after cooking in order to neutralize any lingering vapors and odors in the air. With the delayed shut down function, it is possible to have the fan automatically shut off after a predetermined period of time. – The Con@ctivity 2.0 function is not activated.
Operation (Manual mode) Turning overhead lighting on/ off Tap 1 to turn off the power management. The overhead lighting can be turned on and off separately from the fan. The 1 and IS indicators will flash. Tap the lighting button . The 1 and IS indicators are constantly lit. Power management The ventilation hood features a power management system to help save energy. The fan power level is reduced and the lighting is turned off automatically.
Operation (Automatic and Manual modes) Filter saturation indicator The number of hours the hood has been in operation is stored in appliance memory. The filter saturation indicators show when the filters need to be cleaned or changed by lighting up the grease filter symbol or OdorFree Charcoal Filter symbol . Additional information on cleaning and changing the filters and resetting the filter saturation counters can be found under "Cleaning and care.
Operation (Automatic and Manual modes) Activating/changing the OdorFree Charcoal Filter operating hours counter The OdorFree Charcoal Filter is required for extraction mode. The operating hours counter for the OdorFree Charcoal Filter requires onetime activation and must be set to match your cooking habits. Press the On/Off button to turn the fan off. Tap the delayed shut-down button and the OdorFree Charcoal Filter button at the same time.
Operation (Automatic and Manual modes) Sensor button signal tone Whenever you select a feature with the sensor buttons, you will hear a brief signal tone. You can deactivate this signal tone if you prefer. Press the On/Off button to turn the fan off. Tap the IS and the grease filter buttons at the same time for approx. 5 seconds until a short signal tone is heard. The signal tone is now turned off for all functions. To reactivate the signal tone, follow the same steps.
Cleaning and care WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "IMPORTANT SAFETY INSTRUCTIONS". Stainless steel housing General information The surfaces and control buttons are susceptible to scratching and chipping. Observe the following cleaning instructions. Clean all surfaces and control buttons using warm water and liquid dish soap. Apply with a sponge cloth.
Cleaning and care Important for the controls Do not leave dirt and debris on the buttons for any length of time. Otherwise they may become discolored or damaged. Remove any dirt or debris immediately. Observe the general cleaning instructions contained in this chapter. Do not use a stainless steel cleaner to clean the control buttons. Special instructions for glass surfaces Glass surfaces can be cleaned using a cleaning agent specifically designed for glass.
Cleaning and care Cleaning the grease filters in the dishwasher Place the filters as upright as possible in the lower basket. Ensure that the spray arm is not obstructed. Use a common dishwashing detergent. To remove a grease filter, release the locking clip. Then, open the filter to a 45° angle, unhook it, and remove it from the hood. Cleaning the grease filters by hand Clean the filters with a soft nylon brush in a mild solution of hot water and dish soap. Do not use undiluted dish soap.
Cleaning and care If the filters have been installed incorrectly, you can insert a small screwdriver into the slit to disengage the locking clip. Resetting the filter saturation indicator for the grease filter Once cleaning is complete, the filter saturation indicator must be reset. While the fan is turned on, press the grease filter button for approx. 3 seconds, until only the 1 is flashing. The grease filter symbol goes out.
Cleaning and care When to change the OdorFree Charcoal Filter Disposing of the OdorFree Charcoal Filter Always replace the OdorFree Charcoal Filter whenever it no longer absorbs kitchen odors effectively. Replace the filter at least once every 6 months. Used OdorFree Charcoal Filters can be disposed of with normal household waste. The OdorFree Charcoal Filter saturation counter will light up to remind you to change the charcoal filter regularly.
Installation Before installation Before installing the appliance, read all of the information contained in this chapter and also in the "IMPORTANT SAFETY INSTRUCTIONS" section. Installation parts 4 extension piece holders for aligning and securing the telescopic chimney 4 screws M³/₁₆" x ⁵/₁₆" (M4 x 8.5 mm) for securing the extension piece holders. 4 screws, ¹/₄" x 4 ⁵/₁₆" (7 x 110 mm) and 4 plugs, ³/₈" x 3 ¹/₈" (10 x 80 mm) for securing the ventilation hood to the ceiling (not for use in USA / CDN).
Installation Appliance dimensions a Mounting area for the exhaust ducting and power cable. In recirculation mode, only the power cord is required.
Installation f A power cord is required to connect the hood to the socket in the ceiling. With extraction mode flexible ducting is also required. Exhaust connection 6" (150 mm) Distance between cooktop and ventilation hood (S) Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood. Please also observe the information contained in the "IMPORTANT SAFETY INSTRUCTIONS" section.
Installation Installation recommendations Structural support – We also recommend a distance of at least 26" (660 mm) above electric cooktops to provide more workspace and easier cooking under the hood. – When selecting an installation height, always take the user height into consideration. Users should have ample space to work comfortably on the cooktop and reach the ventilation hood controls with ease.
Installation 85 5/8" m 22 /8" 0 8 m 22 0 mm For vented mode: dai3435aus Draw two intersecting lines on the ceiling. – Place a section of the exhaust ducting in the ceiling and feed it down through the cross-sectional area as illustrated. Exhaust ducting of approx. 27 ⁹/₁₆" (700 mm) length is required between the ceiling and the hood exhaust socket. – Secure the exhaust ducting to the exhaust socket, e.g. with a hose clip (available as an optional accessory) on flexible ducting.
Installation Use a knife to release the four spacers and the two covers from the spacer frame supplied. Drill four holes ³/₈" (10 mm), approx. 4 ¹/₂" (115 mm) deep for the plugs supplied. Use the spacer frame as a drilling template. Place it on the ceiling with the arrows pointing forwards. Using the notches, align the spacer frame on the intersecting lines and make pencil marks for the drill holes.
Installation The spacer frame can be installed between the chimney and the ceiling. This creates a shadow which gives the illusion of a gap between the ceiling and the chimney. This is useful if the ceiling is not level or is uneven. The hood is aligned vertically with the spacers supplied. Visual irregularities between the chimney and the ceiling are then concealed by the shadow. Mount the spacer frame onto the installation frame.
Installation Hang the installation frame on the four screws. The front of the frame is marked with a "V". If using the spacer frame, place the two covers into the fixing holes. 38 Align the installation frame and secure it with the screws. The spacers, which were removed from the spacer frame at the start, can be used to align the hood vertically.
Installation Holding the installation frame securely, remove the two fixing screws and extend the installation frame to its maximum length. Replace the screws. The directional unit from recirculation kit DUI 32 (optional accessory) is installed for recirculation mode (RM): Bend the four retaining tabs on the installation frame outwards. Place the power cord inside the installation frame. Fit the directional unit as shown, noting the marking on the front.
Installation Secure the exhaust socket to the hose using a hose clip. Secure the hose to the directional unit socket using a hose clip. Check that the hose is held securely. Push the telescopic chimney over the installation frame: – with the recirculation grilles at the bottom for vented mode (AE), – with the recirculation grilles at the top for recirculation mode (RM). Bend the two retaining tabs outwards to prevent the telescopic chimney from slipping down again.
Installation Fit the four telescopic chimney clamps. When the screws are tightened, the clamps spread out and push the telescopic expansion piece upwards. Bend back the two retaining tabs. Push the chimney over the telescopic chimney and bend the retaining tabs outwards again to prevent the chimney from slipping down again. Tighten the screws only until the top edge of the telescopic chimney is evenly aligned with the ceiling or the spacer frame.
Installation A non-return flap is supplied with the hood or is already fitted in the exhaust socket of the motor unit (depending on model). With vented mode (AE) insert the non-return flap in the exhaust socket if your ducting system is not equipped with one. Recirculation mode (RM) does not require the non-return flap to be inserted. If there is one present, it should be removed. Hang the hood on the brackets, making sure that the controls are at the front.
Installation Connect the power cord. See "Electrical connection." Unscrew both screws from the installation frame again. Place the exhaust ducting onto the exhaust socket. The canopy can now be adjusted to the desired height, observing the permissible height ranges: – With vented mode: upwards as far as it will go, downwards only to the "A" marking. – With recirculation mode: upwards as far as the "U", downwards as far as it will go. Follow the instructions in "Appliance dimensions.
Installation Raise the canopy to the desired height and secure it with the screws. Hold the chimney securely, bend back the retaining tabs and carefully lower it. The chimney will locate in the cut-out in the canopy.
Installation With recirculation mode (RM) ventilation hoods, insert the OdorFree Charcoal Filter. Remove the grease filters from the hood. Insert the safety screw on the inside. Carefully remove the protective foil from the grease filters. Reinsert the grease filters.
Exhaust duct WARNING: Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only. Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages. To reduce the risk of fire, only use metal ductwork.
Exhaust duct Condensate trap In addition to insulating the exhaust duct, we recommend installing a condensate trap to collect and evaporate any condensate which might accumulate. Condensate traps are available for exhaust ducts with a diameter of 5" (125 mm) or 6" (150 mm). When installing a condensate trap, make sure that it is positioned vertically and, if possible, directly above the hood outlet duct collar. The arrow on the housing indicates the direction of airflow.
Electrical connection WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is OFF while installation or repair work is performed.
Activating Con@ctivity 2.0 Installation of the Con@ctivity 2.0 stick In order for you to be able to use the Con@ctivity 2.0 function, the cooktop must be equipped with a Con@ctivity 2.0 stick. Activating the ventilation hood The cooktop and hood must be turned off. Press the delayed shut down button for approx. 10 seconds until 1 lights up in the fan setting display. See the relevant installation instructions of the Con@ctivity 2.0 stick.
Activating Con@ctivity 2.0 Activating the cooktop Activation failed While the ventilation hood is searching for a wireless connection, start activation on the cooktop. More information can be found in the operating instructions for the cooktop. If a wireless connection cannot be established despite activation of the Con@ctivity function on the ventilation hood and cooktop, the function must first be deactivated and then reactivated on both appliances.
Service and warranty For faults that you cannot resolve on your own, please contact your Miele dealer or Miele Technical Service. MieleCare The telephone number for Miele is listed at the back of these instructions. MieleCare, our Extended Service Contract program, gives you the assurance of knowing that your appliance investment is covered by 5 years of worry free ownership.
Technical data Fan motor Overhead lighting Total connected load Voltage, Frequency Fuse rating Weight 350 W 4x3W 362 W 120 V AC, 60 Hz 15 A 77 lbs (35 kg) Optional accessories for recirculation mode: Recirculation kit DUI 31 and OdorFree Charcoal Filter DKF 12 Contains FCC ID: 2ACUWEI8800 IC: 5669C-EI8800 This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s).
Please have the model and serial number of your appliance available before contacting Technical Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: 800-843-7231 609-419-4298 Fax: www.mieleusa.com Technical Service & Support Nationwide Phone: 800-999-1360 888-586-8056 Fax: TechnicalService@mieleusa.com International Headquarters Miele & Cie.
DA 6690 D en-US M.-Nr.