Installation plan Washer-dryer stack PWT 6089 EL (Electrically Heated) en - US 13.15 M.-Nr.
U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: 800-991-9380 609-419-9898 609-419-4241 Fax: www.mieleusa.com Technical Service & Support Nationwide Phone: 800-991-9380 Fax: 800-220-1348 proservice@mieleusa.
PWT 6089 EL - measurements in inches 11 3/4" 27 1/4" 30" 50 3/4" 19 1/2" 52 5/8" 14 5/8" 76" 76" 20 7/8" 21 1/4" 27 1/4" 17 3/8" 11 3/4" 12 3/4" 15 1/8" 28 5/8" 27 1/2" 43 1/4" 27 1/2" 27 1/4" 30" 27 1/4" 43 1/4" 3
2 1/4" < 39 3/8" 51 1/8" 51 1/8" 42 1/4" < 39 3/8" 51 1/8" PWT 6089 EL - measurements in inches 5 7/8" 43 1/4" 4
3/4" 76" PWT 6089 EL - measurements in inches 17 3/8" 27 1/4" 24 3/4" 2" 22" 27 1/8" 43 1/4" 1 5/8" 14" 4" 1/4" 28" 5
PWT 6089 EL - measurements in millimeters 6
< < < PWT 6089 EL - measurements in millimeters 7
PWT 6089 EL - measurements in millimeters 8
Technical datasheet PWT 6089 LP (Drain pump) Electric (EL) Washer/Dryer stack: Heating: Legend: Abbreviations in bold type: Connection required en - US Abbreviations in circle with dashes: Connection optional or required depending on model version Options/accessoires: Dispensing pump External dispensing pumps (2 or 4 head pump): Voltage (external power supply required) Fusing Supplied with supply cable and plug 120V 15A NEMA 5-15 Pump installation may only be performed by Miele Service.
Electrical isolator Both washer-dryer stack connections must be disengaged by a common electrical disconnect device that switches off all poles in accordance with IEC 60947-1 [Q1]. The electrical isolator [Q1] and plug connections [EL1, EL2] must be located in the immediate vicinity of the machine. Both must be visible, accessible and within easy reach.
Cold water (Soft water) Min. flow pressure Max. pressure Max. throughput On-site connection thread Length of connection hose (supplied: 1 connection hose) 14.5 psi 145 psi 2.9 gal/min ¾" external thread 61“ 100 kPa 1000 kPa 11 l/min ¾" external thread 1550 mm Hourly water demand (average for 60°C program) for standard connection (with hot and cold water) approx. 18.5 gal/h approx. 70 l/h 158°F 14.5 psi 145 psi 2.
Machine data Unit width Unit depth Unit height Casing width Casing depth 27 1/2“ 30“ 76“ 27 1/4“ 27 1/4“ 700 mm 752 mm 1930 mm 692 mm 690 mm Minimum width of delivery access to installation site Recommended rear wall gap Minimum rear wall gap Recommended rear wall gap ensures sufficient space for maintenance and servicing 28 3/8“ 43 5/16“ 35 7/16“ 720 mm 1100 mm 900 mm Net weight Dynamic floor load, max. Static floor load, max. Dynamic load, max. Drum frequency, max.