VL3000 Manager Tool User Guide V1.
Smart Machine Smart Decision Document Title VL3000 Manager Tool User Guide Version 1.00 Date 2013-07-11 Status Release Document Control ID General Notes SIMCom offers this information as a service to its customers, to support application and engineering efforts that use the products designed by SIMCom. The information provided is based upon requirements specifically provided to SIMCom by the customers.
Smart Machine Smart Decision CONTENTS 1. 2. 3. 4. 5. 6. VL3000 Manager Guide ...........................................................................................................5 1.1 Description ..........................................................................................................................5 1.2 Terms and Abbreviations...............................................................................................5 Main Setting.............................................
Smart Machine Smart Decision Revision history Revision Date Description of change Author V1.00 2013-07-11 Initial Zhaolei.yang VL3000 Manager Tool User Guide_V1.05 4 2012.05.
Smart Machine Smart Decision 1. VL3000 Manager Guide 1.1 Description VL3000 manager tool is a PC software which can be used to configure VL3000 through "Data and Charge Cable" interface. It is easy for the backend server developers to configure VL3000 with the manager tool, which has user-friendly interface. The correct command messages sent to VL3000 will be displayed on the management tool. (These messages can also be sent by SMS or GPRS). Follow the steps below to start: 1.
Smart Machine Smart Decision 2. Simtech HS-USB Modem Setting Select the correct com port from the port list, which is displayed in user PC’s "Device Manager" and input the password, with the default value "VL3000". If the password is incorrect, the parameter that users set will not be downloaded to the terminal. 3. The Main Window Function setting AT Command Operations Status VL3000 Manager Tool User Guide_V1.05 6 2012.05.
Smart Machine Smart Decision ¾ Function setting The function setting zone is used to set and view the parameters of the function. ¾ AT Command This column shows the command message which will be sent to the terminal. The command message can also be sent to the terminal through SMS or GPRS. Note: The last parameter of “AT command” (the parameter before ‘$’ character) is the sequence number for command. It will be invoked in the ACK message of the command.
Smart Machine Smart Decision 4. An Example to Configure VL3000 The manager tool is developed based on the VL3000 Air Interface Protocol. Refer to “VL3000 Air Interface Protocol” for detailed references. Following is a general procedure to configure VL3000 with manager tool. 4.1 Set the Parameters of Base Setting Step_1 Step_2 Step_3 Step_4 Step_5 Step_6 Step_7 Step_8 Step_1: Select “Base Setting” option. Step_2: Select “Report Mode”. There are six modes to be selected “0” - “6”.
Smart Machine Smart Decision Step_7: Set “Short TCP Hold Time”. It can be set only when “Report Mode” is set to “1” or “2”. Step_8: Download the base setting. The parameters of GTQSS are changed. 4.2 Set the Parameters of Global Configure Step_1 Step_2 Step_3 Step_4 Step_5 Step_1: Select “Global Configure” option. Step_2: Set a group of parameters: Set “Device Name”. Set the device name, the length of string is 3-10 bytes. Null input means it is the current value without change.
Smart Machine Smart Decision Set “Geofence Check Interval”. Location interval for geofence evaluation, if any geofences are provisioned. Each geofence is evaluated against the location returned at this interval. 0 means no check. Set “SSM2 battery percentage threshold”: Under the premise of setting the “Super sleep mode” parameter to automobile mode (value 2), if the battery percentage is lower than this value, the terminal will enter super sleep mode unconditionally.
Smart Machine Smart Decision 4.3 Set the Parameters of Function Key Step_1 Step_2 Step_3 Step_4 Step_5 Step_6 Step_7 Step_8 Step_1: Select “Function Key” option. Step_2: Set “Power Key” function. Default value is “1”. Step_3: Set “SOS Key Function”. Default value is “0”. Step_4: Set “Disconnect call” function. Default value is “0”. Step_5: Set “SOS Report Interval”. It indicates the interval of GPS information report. Default value is 10 seconds. Step_6: Set “SOS Number”.
Smart Machine Smart Decision 4.4 Set the Parameters of Geo-Fence Step_1 Step_2 Step_3 Step_4 Step_5 Step_6 Step_1: Select “Geo-Fence” option. Step_2: Set the parameter “Confirming Retries”. When a geofence violation is first detected, there shall be this many position retries which attempt to confirm that the position is consistently in violation. The retries shall occur 10 seconds apart. If any of the retries return a position that does not qualify, then the GTGEO report will not be sent.
Smart Machine Smart Decision 4.5 Set the Parameters of Motion Sensor Setting Step_2 Step_1 Step_3 Step_4 Step_5 Step_6 Step_7 Step_8 Step_1: Select “Motion Sensor Setting” option. Step_2: Set “M-threshold” parameter. : M-threshold is a parameter to decide the threshold of Movement Event Report. The movement is judged when terminal detects that its acceleration exceeds the preset acceleration threshold and movement time exceeds the preset movement cycle.
Smart Machine Smart Decision 6: enable both x and y axes acceleration Step_6: Set “Motion Sensor Enable” parameter. 0: disable motion sensor function. 1: enable motion sensor function. Step_7: Select “Super Sleep Mode” parameter. 0: disable 1: normal mode 2: automobile mode Step_8: Download motion sensor setting. The parameters of GTMSS are changed. 4.6 Set the Parameters of Google Link Step_1 Step_2 Step_3 Step_1: Select “Google Link” option. Step_2: Set the number in “White Call List”.
Smart Machine Smart Decision 4.7 Set the Parameters of Fixed Report Information Step_2 Step_1 Step_3 Step_4 Step_5 Step_6 Step_1: Select “Fixed Report Information” option. Step_2: Select “Mode”. 0: disable Fixed Report Function. 1: enable Fixed Report Function. Step_3: Select “Discard no fix”. 0 to report last known GPS position if there is no GPS fix; 1 to send nothing if there is no GPS fix. Step_4: Set a group of parameters: Set “Begin Time” and “End Time”.
Smart Machine Smart Decision 1: enable Set “Movement Speed”. The speed threshold of movement detection. 0 means not to detect speed. Set “Movement Distance”. The distance threshold of movement detection. 0 means not to detect distance. Step_5: Configure the composition of GPS position information for fixed report. GSM Information including: GSM LAI and CI, including , , , ,,.
Smart Machine Smart Decision 1: enable when current speed is in the range. 2: enable when current speed is out of the range. Step_3: Set a group of parameters. Set “Min Speed” .The lower limit of the speed range. Set “Max Speed” .The upper limit of the speed range. Set “Speed Check Interval”. Location interval for speed check purpose. If motion sensor is enabled and no motion is detected then location interval is skipped. 0 means not to check. Set “Speed Send Interval”.
Smart Machine Smart Decision 2: use AssistNow offline AGPS 3: use both AssistNow online and offline AGPS Step_3: Select the “Autonomous control” Step_4: Set a group of online parameters. Set “Online Address”. AssistNow online server Address Set “Online User”. AssistNow online server User Name Set “Online Password”. AssistNow online server password Set “Online Retry Times”. AssistNow online server connect retry times limit Set “Online Update Interval”.
Smart Machine Smart Decision Step_1: Select “FreeFall Detect” option. Step_2: Select “Mode” to disable/enable freefall detection. Step_2: Set “F-count”, the time that the terminal’s acceleration maintains. Step_3: Download the change of freefall detection. The parameters of GTFFA are changed. 4.11 Set the Parameters of Acceptable Incoming White List Number Step_1 Step_2 Step_3 Step_1: Select “Acceptable Incoming White List Number” option. Step_2: Set the number in “Acceptable White Call List” column.
Smart Machine Smart Decision 4.12 Set the Parameters of GPS on Need Step_2 Step_1 Step_3 Step_4 Step_1: Select “GPS on Need” option. Step_2: Select the mode. 0: normal mode 1: always on mode Step_3: Set GPS parameters.
Smart Machine Smart Decision 4.13 Set the Parameters of Extend Setting Step_2 Step_1 Step_3 Step_4 Step_1: Select “Extend Setting” option. Step_2: Select the “Accuracy Parameter”. 0: use accuracy parameter Dop for each GTFRI report 1: use accuracy parameter Satellite number used for each GTFRI report Step_3: Extend Setting. : configure how many seconds the power button needs to be depressed prior to powering off the unit.
Smart Machine Smart Decision 4.14 Set the Renamed Device with the Last 10 Digits of SIM Card(ICCID) Step_2 Step_1 Step_3 Step_1: Select “Renamed Device with the Last 10 Digits of SIM Card(ICCID)” option. Step_2: Select the mode. 0: Restore the device name to original default value “DevName”. 1: Renamed device with the last 10 digits of the SIM card (ICCID) if SIM card is then in existence. Step_3: Download the setting. The parameters of DevName are changed. VL3000 Manager Tool User Guide_V1.
Smart Machine Smart Decision 4.15 Set the Parameters of Protocol Watchdog Step_2 Step_3 Step_1 Step_4 Step_5 Step_1: Select “Protocol Watchdog” option. Step_2: Select the mode. 0: Disable this function. 1: Reboot periodically according to the and
Smart Machine Smart Decision 4.16 Set the Parameters of Time Adjustment Step_2 Step_3 Step_1 Step_4 Step_5 Step_1: Select “Time Adjustment” option. Step_2: Select the Sign. +: positive of the local time offset to UTC. -: positive of the local time offset to UTC. Step_2: Select the Daylight Saving. 0: disable daylight saving time. 1: enable daylight saving time. Step_4: Set “Hour Offset”: UTC offset in hour. Set “UTC Time”: The configuration UTC time. Step_5: Download the setting.
Smart Machine Smart Decision 4.17 Set the Reset Step_2 Step_3 Step_1 Step_1: Select “Reset” option. Step_2: AT Command Step_3: Download the setting. Reset all the protocol command parameter to factory setting, the terminal will restart itself after resetting VL3000 Manager Tool User Guide_V1.05 25 2012.05.
Smart Machine Smart Decision 4.18 Set the Parameters of Password Change Step_2 Step_3 Step_1 Step_1: Select “Password Change” option. Step_2: Change the user password Enter current password in “User Password”. Enter new user password in “New User Password”. Step_3: Download the change of user password. The parameters of GTCFG are changed. VL3000 Manager Tool User Guide_V1.05 26 2012.05.
Smart Machine Smart Decision 4.19 Reading Step_2 Step_1 Step_3 Step_4 Step_1: Select “Reading” option. Step_2: Click “Read Events Information”, the information will show below. Step_3: Click “Read GPS Information”, the information will show below. Step_4: Click “Read Firmware Version”, the information will show below. VL3000 Manager Tool User Guide_V1.05 27 2012.05.
Smart Machine Smart Decision 4.20 History Logs Step_2 Step_1 Step_1: Select “History Logs” option. Step_2: The history logs will be shown. VL3000 Manager Tool User Guide_V1.05 28 2012.05.
Smart Machine Smart Decision 5. Operation Menu The operation menu supports “Read All”, “Download All”, “Export Config”, “Import Config”, “Unlock PIN”, “AT Setting”, “View Log”, “AT Debugging”, and “Exit” functions. 5.1 Read All Read all parameters of VL3000 and list them in the corresponding fields. 5.2 Download All Download all settings to VL3000. 5.3 Export Config “Export Config” exports the current configuration to a new “*.ini” file. VL3000 Manager Tool User Guide_V1.05 29 2012.05.
Smart Machine Smart Decision 5.4 Import Config “Import Config” imports a configuration file. 5.5 Unlock PIN “Unlock PIN” unlocks the PIN of SIM card. 5.6 AT Setting Set the password of AT command. VL3000 Manager Tool User Guide_V1.05 30 2012.05.
Smart Machine Smart Decision 5.7 View Log The document of AT log will pop up. 5.8 AT Debugging User can test AT command through this window. 5.9 Exit Exit the PC Tools. 6. Operation Attention When accomplishing the operation with VL3000 by PC manager tools, exit the tools first then plug out the cable from VL3000. Otherwise the power saving algorithm cannot work. VL3000 Manager Tool User Guide_V1.05 31 2012.05.
Smart Machine Smart Decision Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received,including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant toPart 15 of the FCC Rules.
Smart Machine Smart Decision Contact us: Shanghai SIMCom Wireless Solutions Ltd. Address: Building A, SIM Technology Building, No. 633 Jinzhong Road, Shanghai, P. R. China 200335 Tel: +86 21 3252 3300 Fax: +86 21 3252 3020 URL: www.sim.com/wm VL3000 Manager Tool User Guide_V1.05 33 2012.05.