MLDV Direct Vent Gas Fireplace Model: MLDV500 Installation & Operating Instructions WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. – WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
MLDV Series Gas Fireplace CONTENTS Thank you and congratulations on your purchase of an MHSC Fireplace. PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE! IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Important Safety Information...................................... 3 Checking Gas Pressure - SCS .................................
IMPORTANT SAFETY INFORMATION MLDV Series Gas Fireplace OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. WARNING INSTALLER • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. • Any change to this fireplace or its controls can be dangerous.
MLDV Series Gas Fireplace IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY It is not unusual for gas fireplaces to give off some odor the first time it is burned. This is due to the manufacturing process.
product features MLDV Series Gas Fireplace product SPECIFICATIONS • This appliance has been certified for use with • • • • • • Insulation Board either natural or propane gas. See appropriate data plates. This appliance is not for use with solid fuels. The appliance is approved for bedroom or bedsitting room installations. The appliance must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in Canada.
MLDV Series Gas Fireplace 30(6 ” (784 mm) 20 6 ” (524 mm) Min. Rough Opening Depth 2256M” (565 mm) 2256M” (565 mm) (9 36 21 56M m ” m ) m m ) 1/2” or 5/8” 91 Min. Rough Opening Width (4256O” 91080 mm) 17 56O ”( 72 5256M” (1327 mm) 5256M” (1327 mm) FIREPLACE and FRAMING DIMENSIONS Min.
installation information MLDV Series Gas Fireplace Before You Start Fireplace Location Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received.
clearances MLDV Series Gas Fireplace WARNING Clearances to combustibles Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
SECURe FIREPLACE to floor or framing MLDV Series Gas Fireplace NOTE The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side nailing flanges are 1/2" or 5/8" to accommodate different wall thickness.
VENTING INSTALLATION MLDV Series Gas Fireplace Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life. NOTICE WARNING Venting installation Failure to follow these instructions will void the warranty.
Venting installation MLDV Series Gas Fireplace The appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent configuration, the appliance can be converted by following the steps below. When removing and refitting the plates and adapter, be sure the associated gaskets are undamaged and refitted as required.
Venting installation Horizontal sections of this vent system require a minimum of 3” clearances to combustibles at the top of the flue and 1” clearance at the sides and bottom until the flue penetrates the outside wall. A minimum 1” clearance all around the flue is acceptable at this point of penetration. If vertical rise is 7Z\x” feet or higher when top venting, the clearance to combustibles is 1” on all sides of the horizontal run.
MLDV Series Gas Fireplace There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness. for horizontal termination Select the amount of vertical rise desired. All horizontal run of venting must have 1/4" rise for every 12" of run towards the termination below 71/2 feet of vertical rise.
MLDV Series Gas Fireplace venting installation General Venting Information - Termination Location INSIDE CORNER DETAIL G V H A D L V E C B V F Figure 11 Horizontal Vent Termination Locations B Fixed Closed Ope rable V B B V Operable B B J X X AIR SUPPLY INLET V K X AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations1 CFM145a DV Termin Location 5/01/01 Rev.
venting installation MLDV Series Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Alcove Applications* Inside Corner Outside Corner G= Combustible 6" (152 mm) G Noncombustible 2" (51 mm) V C V E O F Balcony with perpendicular side wall Balcony with no side wall Figure 12 Allowable Venting F= Combustible 6" (152 mm) Noncombustible 2" (51 mm) V D C E = Min. 6” (152 mm) for non-vinyl sidewalls Min.
MLDV Series Gas Fireplace venting installation REAR WALL VENT INSTALLATION (5" x 8" VENTING ONLY) When installed as a rear vent unit, this appliance may be vented directly to a termination located on the rear wall behind the appliance. Only an MHSC brand termination is allowed for this application. • The maximum horizontal distance between the rear of the appliance and the termination is 20" (508 mm).
MLDV Series Gas Fireplace venting installation REAR WALL VENT INSTALLATION (continued) WARNING 1" to combustibles is maintained. Attach the vent cap with four (4) wood screws supplied. Figure 17 NOTE: Replace the wood screws with appropriate fasteners for Vent Cap stucco, brick, concrete or other types of siding. For vinyl siding, stucco or wood exterior, use vinyl siding standoffs between vent cap and exterior wall for Simpson or Selkirk Terminations only.
MLDV Series Gas Fireplace venting installation HORIZONTAL WITH VERTICAL RISE (THROUGH-THE-WALL) TERMINATION CONFIGURATIONS Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to. The Vent Graph, showing the relationship between vertical and horizontal side wall venting, will help to determine the various dimensions allowable.
venting installation MLDV Series Gas Fireplace 90° HORIZONTAL (THROUGH-THE-WALL) TERMINATION CONFIGURATION (continued) • If a 90° elbow is used in the horizontal vent run (level height A maintained) the horizontal vent length is reduced by 36". Figure 23. This does not apply if the 90° elbows are used to increase or redirect a vertical rise. Figure 22 B Example: According to the vent graph (Page 17) the maximum horizontal vent length in a system with a 7.
MLDV Series Gas Fireplace venting installation Horizontal with vertical rise (through-the-wall) applications 1. Locate and cut the vent opening in the wall. For combustible walls first frame in opening. 101/2" (267 mm) Combustible Interior Walls: Cut a 12Z\x"H x 10Z\x" W hole through the interior wall. WARNING Combustible Exterior Walls: Cut a 10Z\x"H x 10Z\x"W square hole through the exterior wall frame. Figure 25 Noncombustible Walls: Hole opening should be 8Z\x" (216 mm) in diameter. 2.
venting installation MLDV Series Gas Fireplace Below Grade Installations When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178 mm) below grade level. The 7" (178 mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall. Ensure that sidewall venting clearances are observed.
MLDV Series Gas Fireplace venting installation Install restrictor disc as shown in Figure 29 for vertically vented applications. Up to two (2) restrictor discs may be needed for 40' installation. The two (2) restrictor discs suppled will work for most installations. If a third disc is needed order Part No. 56D3027. NOTICE vertical through-the-roof applications A restrictor disc must be installed on any vertical termination that is higher than 12'.
venting installation MLDV Series Gas Fireplace vertical (through-the-roof) applications (continued) This Gas Fireplace has been approved for, • Vertical installations up to 40' (12 m) in height. Up to a 10' (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. Figure 30 40' Max. Height 8' Min. Height 10' Maximum 10' Maximum 40' Max. Height 8' Min.
MLDV Series Gas Fireplace venting installation installation for vertical termination 1. Determine the route your vertical venting will take. If ceiling joist, roof rafters or other framing will obstruct the venting system, consider an offset. Refer to Figure 32 to avoid cutting load bearing members. NOTE: Pay special attention to these installation instructions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, etc.
venting installation MLDV Series Gas Fireplace installation for vertical termination - Flat Ceiling installation (continued) 5. Place the flashing over the pipe section(s) extending through the roof. Secure the base of the flashing to the roof and framing with roofing nails. Be sure roofing material overlaps the top edge of the flashing. There must be a 1" clearance from the vent pipe to combustible materials. 6.
MLDV Series Gas Fireplace Flex vent installation 1. Flexible UL1777 listed venting may be used in any venting application where rigid direct vent components can be used. All restrictions, clearances and allowances that pertain to the rigid piping apply to the flexible venting. Flex kits may not be modified. Flex kits may be added to the end of a vent run made of rigid vent sections using pipe manufacturer's approved flex to pipe adapters.
MLDV Series Gas Fireplace flex vent installation D. Attaching flexible venting to vertical termination assemblies. 1. When using Simpson pipe, an MHSC flex-to-pipe adapter and/or rigid pipe section(s) is required to connect the flexible vent assembly to the vertical termination by using three self-penetrating screws. 2. Review Figure 39 and corresponding instructions for proper overlap, clamp and screw placement. 3.
MLDV Series Gas Fireplace FLEX vent installation 4" x 7" Flex Pipe If you prefer to use 4" x 7" flex pipe, you must install model 7TDVP58 reducer (5" x 8" to 4" x 7") onto the fireplace collar. Then follow the assembly guidelines for 5" x 8" flex venting.
fireplace installation MLDV Series Gas Fireplace check gas type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. A qualified installer or service person must connect appliance to gas supply. Follow all local codes.
fireplace installation Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. CAUTION WARNING MLDV Series Gas Fireplace A manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8” NPT pressure tapping point should be installed upstream of the appliance. Figure 46 NOTE : The gas line connection may be made using 1/2" rigid tubing or an approved flex connector.
Millivolt - CHECKING GAS PRESSURE and Electrical installation MLDV Series Gas Fireplace WARNING 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. 2. To ease installation, a 24" (610 mm) flex line with manual shut-off valve has been provided with on this appliance. Install and attach 1/2" gas line onto shut-off valve. 3.
MLDV Series Gas Fireplace REMOTE WALL SWITCH INSTALLATION Remote Wall mounted Switch OPTIONAL REMOTE WALL SWITCH ON OFF PILOT HI ON A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 48. Do not extend beyond the wall switch wire length provided. LO TH TP TH/TP ON OFF RS OFF WARNING NOTE: Extended lengths of wire may cause the fireplace not to function properly.
OPTIONAL FAN/BLOWER SYSTEM MLDV Series Gas Fireplace Magnet KT503 Figure 50 Magnet Installation 10.Turn blowers with discharge vent facing up. Slide the discharge vent so that it is facing up. Slip discharge vent flange under the KT503the sidewall. Slide blower side tabs Figure 51 flange bracket flush against magnets Blower Installation over into side flange.blower Figure 52. The blower is now locked in place. 11/08 11.
MLDV Series Gas Fireplace OPTIONAL FAN/BLOWER SYSTEM Finishing 1. Re-install the lower access panel. 2. To use the blower, turn the knob on the speed control clockwise. The blower should be operating at the highest speed. Continue to turn the knob until it reaches the desired speed. NOTE: Some older units are not equipped with mounting brackets. Velcro and magnets are used to mount blowers to sidewall and floor.
OPERATING INSTRUCTIONS (Milli-volt) MLDV Series Gas Fireplace WARNING for your safety read before lighting If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas.
MLDV Series Gas Fireplace OPERATING INSTRUCTIONS (Milli-volt) approved leak testing method You may check for gas leaks with the following methods only: • Soap and water solution • An approved leak testing spray danger • Electronic sniffer Never check for gas leak with open flame! WARNING Lighting pilot for the first timE If using a soap and water solution to test for leaks, DO NOT spray solution onto control body. NOTE: Remove any excessive pipe compound from the connections.
OPERATING INSTRUCTIONS (milli-volt) MLDV Series Gas Fireplace Lighting burner OFF RS The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON” position to light the main burner. ON main burner switch On/Off/RS Switch Lighting the burner Depress and turn the knob counterclockwise to the “ON” position.
SIGNATURE MLDV Series GasCOMMAND Fireplace - CHECKING GAS PRESSURE and Electrical installation 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. 2. To ease installation, a 24" (610 mm) flex line with manual shut-off valve has been provided with on this appliance. Install and attach 1/2" gas line onto shut-off valve. 3.
ELECTRICAL INSTALLATION MLDV Series Gas Fireplace JUNCTION BOX WIRING 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing codes. 2. Remove the external junction box cover by removing the screw from the side of the outside firebox wall. Junction box was installed at the factory. 3. The junction box cover has a factory installed “romex” style strain relief connector.
MLDV Series Gas Fireplace ELECTRICAL INSTALLATION Optional AC Module To Junction Box in Fireplace Pilot { Plug in Connector Optional Blower Optional Light { White Black White Black Optional { White Black Aux. Green Connector Pin To Control Board Input 300 Watt Max.
OPTIONAL FAN BLOWER SYSTEMS The black and white wires on the AC box wiring harness are marked ‘Blower’, ‘Light’ and ‘Aux’. It is important to use the wires marked ‘Blower’ or the control will not work correctly. WARNING WARNING Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
MLDV Series Gas Fireplace OPTIONAL FAN BLOWER SYSTEMS BLOTSDV AUTOMATIC THERMOSTAT BLOWER 120VAC Receptacle Junction Box BLACK GREEN WHITE BLACK WHITE BLACK BLACK Speed Control Figure 60 BLOTSDV Blower Wiring Diagram Before installing the blower, wire the receptacle into an electrical circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance FP2685 with prevailing codes.
OPERATING INSTRUCTIONS - SIGNATURE COMMAND MLDV Series Gas Fireplace WARNING for your safety read before lighting If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions. B. BEFORE OPERATING smell all around the appliance area for gas.
MLDV Series Gas Fireplace OPERATING INSTRUCTIONS - SIGNATURE COMMAND OPERATing INSTRUCTIONS 1. STOP! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. With five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on page 38. If you do not smell gas, go to next step. 4.
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS MLDV Series Gas Fireplace FEATURES Command Center RF Receiver ON/OFF • Easy Access Function Operation and System Configuration • Operation Confirmation/Fault Diagnostic Indications (LED/ Buzzer) • ON/OFF/HI/Med/Low Operation • Optional Wall Mounting Control Board • • • • • • • • • • Electronic Ignition Pilot Lockout safety feature Electric Power Regeneration from Thermopile to save battery 6-hour Automatic Shut Down Option Convenient NG/LP Gas Type Conve
MLDV Series Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS SYSTEM CONFIGURATION/SETUP All System configuration/setup is done on the Command Center. NOTE: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center. Intermittent/Standing Pilot Setup (Default intermittent) 1. Holding the ON button on the Command Center while turning on the master switch will toggle between standing pilot and intermittent pilot. 2.
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS MLDV Series Gas Fireplace FUNCTIONS/OPERATION Turning on the fireplace 1. Turn on the master switch and wait for a beep. 2. Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High setting or last memory setting (See Turning Off Fireplace below). For memory feature. Pilot Safety Lockout Function 1. If the pilot doesn’t light after sparking for 30 seconds, pilot trial lockout happens.
MLDV Series Gas Fireplace glass removal and brick installation Glass Frame Removal caution 1. Remove access panel by lifting up and out. 2. Release three (3) clamps on bottom of fireplace. Figure 62 3. Tilt glass frame out and lift glass frame up until it clears hook on top of fireplace. 4. Set glass frame aside. Glass Frame Each clamp has a quick spring force. When reinstalling clamps, keep fingers clear. ! WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED.
logs and rock wool installation MLDV Series Gas Fireplace 1. Distribute one layer of rock wool to cover all round burner ports. Do not cover rectangular slots, located in front and rear. Figure 64 FP1983 Figure 64 Rock Wool Placement on Burner. FP1983 MLDV rock wool place 2. Place log #1 by setting the log over the rear bracket over the two pins. Figure 65 Log #1 LG543 Figure 65 Install log #1 75D0004 WARNING LG543 Note: Placing rock wool on burner provides glowing MLDV log #1 embers.
MLDV Series Gas Fireplace log installation 3. Place log #2 at angle across the burner by setting the logs over the two pins located on top of the burner. Figure 66 Log #2 Figure 66 Install Log #2 LG544 4. Place log #3 at an angle over log #2 toward the back by matching the rectangular notch on the bottom of this log with the rectangular protrusion on log #2.
log installation MLDV Series Gas Fireplace 6. Place log #5 by matching the rectangular notch on the bottom of the log with the rectangular protrusion on log #2, then set the notch on the bottom of this log over the very far left tong on the grate. Figure 69 Log #5 Figure 69 Install Log #5 LG547 7. Place log #6 at an angle over log #5 toward LG547 the back by matching the rectangular notch MLDV log #5of this log with the rectanguon the bottom lar protrusion on log #5.
WARNING MLDV Series Gas Fireplace cleaning and maintenance Thermocouple Sensor Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. Thermopile Burner, Pilot and Control Compartment Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year.
cleaning and maintenance MLDV Series Gas Fireplace Venting SysteM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function. Glass Door Thoroughly clean the inside of the glass door after using the fireplace for ten hours. Periodically clean the glass door as necessary.
MLDV Series Gas Fireplace troubleshooting Standing Pilot Ignition MILLIVOLT SYSTEM SYMPTOM POSSIBLE CAUSE ACTION 1. Spark ignitor will not light pilot after repeated triggering of piezo. A. Wire disconnected. A. Open door and check to make sure wire is connected to ignitor. B. Check for spark at electrode and pilot. If no spark and electrode wire is properly connected, replace pilot assembly. C. Check remote/manual shut off valve from fireplace.
troubleshooting MLDV Series Gas Fireplace Standing Pilot Ignition MILLIVOLT SYSTEM SYMPTOM POSSIBLE CAUSE 4. Frequent pilot outage problem. A. Pilot flame may be too high A. Clean and adjust the pilot flame for maximum flame or too low, causing pilot impingement on thermocouple. safety to drop out 5. The pilot and main burner extinguish while in operation A. Inner vent pipe leaking exhaust gases back into system B. Horizontal vent improperly pitched C. Improper vent cap installation A.
MLDV Series Gas Fireplace troubleshooting SIGNATURE COMMAND SYSTEM OPERATION Install batteries and/or plug in the AC board FAULT No beep in about 8 seconds A Using battery? Make sure Command Center and the control board are connected by a 2 feet or 15 feet cable After the beep Flip the master switch (rocker switch) to the ON position Press the ON button on the Command Center No beep or no sound from the valve indicating pilot solenoid open B No sparking on the pilot C Sparking doesn’t contin
replacement parts MLDV Series Gas Fireplace firebox components and accessories 4 5 7 2 8 3 8 Item Description Qty. MLDV500 Standard Features 1. Junction Box Assembly (not shown) 75D0004 1 26D2128K 2. Control Cover 1 74D0119 MLDV parts 3. Glass Frame Assembly 1 75D1016 4. Insulation Board 1 75D0008 5. Eyebrow 1 20302777 Accessories/Field Installed Options 6. Decorative Mesh Glass Cover (not shown) 1 MLDV500SD 7. Firebrick Walls - Cottage Clay 1 FBMLDV500CC 7.
MLDV Series Gas Fireplace replacement parts LOGS Item 1. 2. 3. 4. 5. 6. 7. 58 Description Qty.
replacement parts MLDV Series Gas Fireplace STANDING PILOT - MILLIVOLT CONTROL 2I 1 2C 2T 2 5 4 6 3 8 9 7 10 11,12, 13, 14, 15 0004 MLDV control parts 75D0004 59
MLDV Series Gas Fireplace replacement parts Standing Pilot – Millivolt Control Item Description Qty. 1. Gas Valve Assembly 1 2. Pilot Assembly 1 2C. Replacement Thermocouple 1 2I. Replacement Igniter and Wire 1 2T. Replacement Thermopile 1 3. Burner Tube 1 4. Flex Hose w/Shutoff Valve 1 5. Rocker Switch 1 6. Piezo Igniter 1 7. Injector 1 8. Burner Assembly 1 9. Venturi 1 10. Wire Assembly 1 10. Wire Assembly 1 Accessories 11. Thermostatic Remote Control 1 12. On/Off Remote Control 1 13.
replacement parts MLDV Series Gas Fireplace SIGNATURE COMMAND SYSTEM 1 2 4 3 5 6 8 7 12 13,14,15,16,17 9 19 0004 SG parts 8/08 75D0004 61
MLDV Series Gas Fireplace replacement parts SIGNATURE COMMAND SYSTEM Ref. 1. 2. 3. 4. Description Qty. Gas Valve Assembly 1 Pilot Assembly 1 Control Box 1 Command Center 1 5. Burner Tube 1 6. Flexhose with Shutoff Valve 1 7. Injector 1 8. Burner Assembly 1 9. Venturi 1 10. Wire Valve/Control (not shown) 1 11. Wire Command Center Control Box 2 feet (not shown) 1 12. A/C Adapter (6 Volt) 1 Accessories 13. Hand Held Remote Control w/ HI/LO and Timer 14. Hand Held Remote Control w/ Hi/lo And Tstat 15.
VENTING COMPONENTS MLDV Series Gas Fireplace 1 7 4 8 9 HO T 5 2 3 6 11 10 0004 MLDV vent parts For more information about, or instructions for, the venting components referenced above, please contact the component manufacturer: Selkirk Corporation: www. selkirkcorp.com or 800-992-8368 Simpson Duravent: www. duravent.
MLDV Series Gas Fireplace VENTING COMPONENTS VENT COMPONENTS FOR 4" X 6B\," Qty.
VENTING COMPONENTS MLDV Series Gas Fireplace VENT COMPONENTS FOR 5" X 8" Current Old Simpson Simpson Duravent Duravent Qty./ or MHSC or MHSC Selkirk Metal-Fab Item Box Description Part no. Part no. Part no. Part no.
VENTING COMPONENTS MLDV Series Gas Fireplace HORIZONTAL VENTING - 4" x 7" Horizontal Vent Termination Kits Description Model Number Rear Vent Hot Touch Termination Kit w/ 10" to 16" 7TBRHTK Adjustable Termination Pipe, Firestop, and Hot Touch Termination w/ Siding Shield Up and Out Side Wall Termination Kit w/ 10" to 16" 7TDVSCTK Adjustable Termination Pipe, 90° Elbow, Firestop, and Cool Touch Termination w/ Siding Shield Rear Vent Cool Touch Termination w/ Siding S
VENTING COMPONENTS MLDV Series Gas Fireplace VERTICAL VENTING - 4" x 7" Description Vertical Vent Termination Kits Model Number Vertical Vent Termination w/ Storm Collar (flashing NOT included) 7TDVSKV Vertical Vent Termination w/ Storm Collar - 8 pack (flashing NOT included) 7TDVSKV/8 Vertical Vent Termination w/ 1/12 - 6/12 Flashing, Storm Collar and Ceiling Support Kit 7TDVSKVA* Vertical Vent Termination w/ 6/12 - 12/12 Flashing, Storm Collar and Ceiling Support K
MLDV Series Gas Fireplace 68 75D0004
MLDV Series Gas Fireplace 75D0004 69
MLDV Series Gas Fireplace Massachusetts Residents Only — Please read and follow these special requirements NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Any residence with a direct vent product must have a CO detector installed in the residence.
MLDV Series Gas Fireplace Limited lifetime warranty policy Lifetime Warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. Five Year Warranty The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
Based on CSA P.4.1-09 Efficiency Ratings Model MLDV500NV MLDV500PV EnerGuide Ratings Fireplace Efficiency (%) 70.5 76.4 D.O.E. (AFUE%) 67.1 67.3 Recherchez dans la brochure les caractéristique de rendement énergétique de foyer au gaz Énerguide Based CSA P.4.1-09 Selonon CSA P.4.1-09 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.