WESROC® RMS Cellular Tank Monitor Model MT-9100CTM Operation Manual 72-70-164, Rev.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Table of Contents Safety Information.......................................................................................................................................................4 Hazardous Environments........................................................................................................................... 4 Battery Replacement.....................................................................
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. System Configuration Parameters ...........................................................................................................................18 General..................................................................................................................................................... 18 Parameter List.............................................................................................
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Safety Information Hazardous Environments ® The WESROC RMS Cellular Tank Monitor (CTM) is designed for safe use in environments containing hazardous vapors. However, certain precautions need to be taken to ensure the safety of the person(s) working with the CTM, the tank, and any associated equipment.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Overview Device Characteristics The WESROC® RMS Cellular Tank Monitor (CTM) is used to remotely monitor the level of the contents of a tank. The tank level and additional event and status information are reported to the WESROC® RMS Host System (Host) at scheduled intervals. In addition, the CTM will report to the Host immediately to track tank events in real time.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Installation Mounting Location The WESROC® RMS Cellular Tank Monitor (CTM) is designed to be installed directly on the tank to be monitored. The CTM is connected to the tank gauge by the tank level sensor and sensor cable. The CTM itself may be attached to the tank by the supplied mounting magnets or by a mounting bracket. The CTM may also be located away from the tank if necessary to improve cellular reception.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Host Information The customer information, installation location, and tank configuration for the proposed installation site must be entered into the WESROC® RMS Host System (Host) BEFORE the CTM is installed on the tank. A WESROC® RMS Installation Information Worksheet outlining the required information fields is available from your host administrator or from Independent Technologies, Inc.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. 7] Connect the sensor at the end of the sensor cable to the remote ready dial. This is accomplished by sliding the sensor into the sensor slot on the top of the dial. Slide the sensor from the side towards the center of the dial until it is fully seated. You will hear or feel a small “snap” once it is fully seated.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Operation General After the WESROC® RMS Cellular Tank Monitor (CTM) has been installed on the tank to be monitored; it will periodically report tank level and activity data, and system status information to the WESROC® RMS Host System (Host). Reports can be triggered by expiration of a scheduled report interval timer, or by tank level events or conditions.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. changed since the last measurement. Actions may include starting or ending the qualification of a tank level event, reporting a tank level event to the Host, or reporting to the Host at a scheduled report time. While in Normal mode, the CTM is also constantly monitoring itself for any conditions that may require reporting to the Host.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Tank Level Measurement The CTM wakes up and measures the level of the tank contents once per minute. This enables the CTM to be very responsive to changing tank level conditions and to more accurately qualify events such as tank fills or tank draws. The tank level is reported in a number ranging from 0 to 99, representing the tank level in percent full.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Tank Critical Low Condition: A tank critical low condition will be qualified by the CTM when the tank level has dropped below the configured tank critical low threshold. Missing Sensor Condition: A bad or missing sensor condition will be qualified by the CTM when the tank level has dropped to 0% for a pre-determined amount of time. The qualification of this condition is not configurable.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Portable Diagnostic Unit General The handheld WESROC® RMS Portable Diagnostic Unit (PDU) is used to configure and monitor the status of the WESROC® RMS Cellular Tank Monitor (CTM). This valuable device should be considered an essential part of any installation tool kit. The following is a summary of the sections of the PDU interface that are designed for use with the CTM.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. PDU Screens Logo Screen: This is the first screen displayed when the PDU is powered up. This screen will contain the Independent Technologies logo, or may contain your company logo if arrangements have been made for a custom logo. Press the right arrow key on the PDU to move to the List Screen. This screen will only be displayed once when the PDU is powered on.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Menu Screen: This screen contains a list of screens that can be selected depending on what type of action you want to take. Press the up arrow or down arrow keys to select the desired screen. Press the right arrow key to move to the selected screen. Press the left arrow key to return to the List Screen. At the bottom of this screen is a Ping command that can be executed by pressing the right arrow key.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. System Configuration Screen: This screen contains a list of CTM system configuration parameters. Press the up arrow and down arrow keys to select a configuration parameter to change. Not all of the system configuration parameters are visible on the screen at the same time. Press the right arrow key to move to the selected configuration parameter editing screen. Press the left arrow key to return to the Menu Screen.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. View Details Screen: This is a series of screens that can be used to view detailed information about the CMT system status, the tank level status and history, and information about the cellular network during the last report to the Host. Press the up arrow and down arrow keys to move between the various detail screens. Press the left arrow key to return to the Menu Screen.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. System Configuration Parameters General The WESROC® RMS Cellular Tank Monitor system configuration parameters can be modified using the WESROC® RMS Portable Diagnostic Unit (PDU). These configuration parameters can also be modified by the WESROC® RMS Host System (Host) during a report. Parameter List Base ID: Used to identify a particular CTM device in the Host database.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. High Temperature Threshold: The high temperature alarm threshold in degrees F. Min: -67 F; Max: +302 F Default: +150 F (Effectively Disabled); Disable: 0x8000 (From host only.) Low Temperature Threshold: The low temperature alarm threshold in degrees F. Min: -67 F; Max: +302 F Default: -50 F (Effectively Disabled); Disable: 0x8000 (From host only.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Tank Fill Threshold: The tank fill event qualification amount in percent full. Min: 3%; Max: 95% Default: 5%; Disable: 0% Tank Draw Threshold: The tank draw event qualification amount in percent full. Min: 3%; Max: 95% Default: 10%; Disable: 0% Critical High Threshold: The tank critical high condition level in percent full.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Battery Replacement The WESROC® RMS Cellular Tank Monitor (CTM) uses a field replaceable, intrinsically safe battery pack designed and supplied by Independent Technologies, Inc. The CTM has been designed to operate on a very small amount of power, but eventually the battery pack will need replacement.
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Specifications Mechanical Size: Weight: Mounting: 7.6”L x 5.3”W x 5.6”H Approximately 1.5 lbs Dual channel magnet or right-angle bracket. Environment Temperature: -40C to +60C Power Source Model: Type: Voltage: Expected Life: MT-9100BPK-02 (Available from Independent Technologies) Field replaceable, sealed and intrinsically safe battery pack. 3.6VDC Greater than 5 years (reporting once per day).
WESROC® RMS Cellular Tank Monitor - Operation Manual - Independent Technologies, Inc. Certifications UL The WESROC® RMS Cellular Tank Monitor has been certified for use as Tank Monitoring Equipment in Class I, Division 1, Groups C and D Hazardous (Classified) Locations per ANSI/UL 913 and CAN/CSA C22.2 No. 157.