METROLOGIC INSTRUMENTS, INC.
Locations: USA Corporate Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012 Customer Service: 1-800-ID-METRO Tel: 609-228-8100 Fax: 609-228-6673 EMAIL: info@metrologic.com INTERNET: http://www.metrologic.com Mailing Address: P.O. Box 307 Bellmawr, NJ 08099-0307 South America Metrologic Instruments Centro Ciudad Comercial Tamanaco Torre B, piso 6, ofic. 603-B Chuao 1064 Caracas, Venezuela Tel: 58-2-959-8911 Fax: 58-2-959-9328 EMAIL: info@sa.metrologic.
Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Unpacking List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Scanner Connections to the Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Configuration of the Scanner to the Host System . . . . . . . . . . . . . . . . . . . . . . 3 Parts of the Scanner . . . . . . . . . . . . . . . . . . . . . .
Introduction Metrologic's TECH 10 laser bar code projection scanner is encased in a NEMA-12 steel case. The scanner's construction enables the scanner to operate in harsh surroundings, especially industrial environments. Waterresistant, shock-resistant, and rugged, the TECH 10 scanner is also fast, aggressive and reliable. It can register bar codes at a range of 203mm 559mm (8" - 22") and can autodiscriminate among all common codes.
Scanner Connections to the Host In order for the TECH 10 scanner to maintain compliance with applicable standards, all circuits connected to the scanner (Example: power supply, host system, etc.) must meet the requirements for SELV (Safety Extra Low Voltage) according to EN60950. To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1. Turn off the host system. 2.
Configuration of the Scanner to the Host System The scanner is shipped from the factory programmed to a set of default conditions noted in the ScanSelect™ Scanner Programming Guide by an asterisk that appears before the brief definition next to the bar code. In order for the scanner to communicate with the host system properly, it needs to be programmed to meet your specific scanning needs. Since each host system is unique, the scanner must be configured to match the host system requirements.
Parts of the Scanner Becoming familiar with the features of the TECH 10 scanner will help when operating the scanner. The following illustration and list explain the pertinent parts. 4 1 Green and Red LEDs When the green LED is on, this shows that the unit is receiving power and the laser is on. When the red LED flashes on, the scanner has read a bar code successfully. When the red light turns off, communication to the host is complete. 2 Laser Output Window Laser light is emitted from this aperture.
Installation of the Stand With the Metrologic stand (Part #45479), the scanner can be positioned in a vertical orientation. To use this stand, four 6-32 x ½" machine screws and two #10 panhead wood screws will need to be purchased. The maximum distance the screws should go into the scanner is ½ inch. 1. Lay the scanner face down on a clean cloth to prevent any scratches from occurring on the output window. Position the scanner so the red and green LEDs are pointed toward you. 2.
Figure 2 6
Labels A label is inside the window of the scanner noting that this device is a CDRH Class IIA laser product and IEC 825 LASERKLASSE 1. Also, on the scanner is a label on the back of the unit. This label contains information such as the model number, date of manufacture, and serial number. The following are samples of the labels that are found on the unit. Scanning Bar Codes The depth of field for the scanner is 254mm to 559mm (10" to 22") from the scanner window.
Maintenance Smudges or dirt that appears on the scanner window can interfere with proper scanning. Therefore, only maintenance required is an occasional cleaning of the glass window. 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently wipe the scanner window.
Appendix A Specifications Application: Light Source: Laser Class: Certifications: EMC: Universal Industrial Scanner Visible Laser Diode 670 ± 5nm CDRH: CLASS IIa; EN 60825 Class 1 CE, UL listed for US and Canada FCC Class A, CISPR Class A Mechanical Dimensions: Weight: Orientation: Mounting: Top Cover: 311mm x 262mm x 108mm (12.25"L x 10.32"W x 4.25"D) 5.19 kg. (11.45 lbs.
Operational Depth of Scan Field: Scan Speed: Scan Pattern: Exit Angle: Indicators: Beeper Operation: Maintenance Required: Decode Capability: System Interfaces: Print Contrast: Roll, Pitch, Yaw: 254mm to 559mm (10" to 22") 1,250 scan lines per second 25 line omnidirectional 12E down off perpendicular of scan window LED: red = good read; green = laser on Selection of 3 tones for “Good Read” Clean window periodically Autodiscriminates RS232C; Light Pen Emulation; OCIA; RS422 35% minimum reflectance differenc
Appendix B Pin Assignments for the Mil spec Connector Each TECH 10 scanner has a 19-pin male Mil spec connector that is on the side of the unit. To connect the scanner to the host device, use a communication cable with a female Mil spec connector. The communication cable may include a power transformer or it may be designed to draw power directly from the host device. This item can be ordered when the scanner is purchased. The following is a list of the pin assignments.
Appendix C Warranty and Disclaimer Limited Warranty Products manufactured by Metrologic have a 2-year limited warranty from date of manufacture. This warranty is limited to repair, replacement or refund at Metrologic’s discretion. Faulty equipment must be returned to the Metrologic facility in Blackwood, New Jersey or Puchheim, Germany. To do this, contact Metrologic Customer Service/Repair for a Returned Material Authorization (RMA) number.
Disclaimer Metrologic Instruments, Inc. and the author or authors make no claims or warranties with respect to the contents or accuracy of this publication, or the product it describes, including any warranties of fitness or merchantability for a particular purpose. Any stated or expressed warranties are in lieu of all obligations or liability for any damages, whether special, indirect, or consequential, arising out of or in connection with the use of this publication or the product it describes.
Appendix D Notices Notice This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Anmerkung Nach Überprüfung dieses Geräts wurde festgestellt, daß es den Grenzwerten für Digitalgeräte der Klasse A gemäß Teil 15 der Richtlinien der US-amerikanischen Bundesbehörde für das Fernmeldewesen entspricht. Diese Grenzwerte wurden festgelegt, um einen angemessenen Schutz gegen schädliche Auswirkungen bei Einsatz des Geräts in einer Ladenumgebung zu gewähren.
Appendix E Patents “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.
Index F Faulty equipment 12 Fax ii Function(s) 11 A AC 2, 9 Application 9 Asia ii ASIC 1 Assignments pin 11 G Germany (GmbH) Good read 10 Green LED 4, 5 B Bar code(s) 1, 3, 4, 7 Beep 3 Beeper operation 10 ii, 12 H Headquarters ii Host 2, 3, 4, 11 Humidity 10 C Cable communication 1, 2, 4, 11 CDRH class IIa 7 Clean 14, 16 Compliance 2 Configuration 3 Copyright ii Current 9 Customer Service ii, 12 I IEC 825 LASERKLASSE 1 7 Indicators LED 4, 5, 10 Interfaces 10 Installation Stand 5 Internet ii Introduct
Mechanical 9 Mil spec connector 11 Model number 7 Mounting 9 N NEMA-12 steel case Notices 14, 15 O Operating current 9 Operating temperature Operation 3, 10 Operational 10 Output window 4, 5 P Parts 4 Patents 16 Power consumption Print contrast 10 Programming guide R Red LED Repair 12 Rights property warranty RMA 12 Roll, pitch, yaw RS-232 10, 11 S Scan field Scan lines Scan pattern Scan speed ScanSelect ScanSet 3 Service 12 Shipping carton Shock 10 Socket-outlet 18 4 16 12 10 10 10 10 10 1, 3 1 2 2, 4