MT400 Environment Monitoring Series Operation and Installation Manual
B1-MT400 [Manufacturer]: Wuhan Huchuang Union Technology Co., Ltd. [Production Address]: No.1 Workshop, 1F, Building B10, Wuhan Hi-Tech Medical Device Park, No. 818 Gaoxin Avenue, East Lake Hi-Tech Development Zone, Wuhan, Hubei, China [After-Sales Service Unit]: Wuhan Huchuang Union Technology Co., Ltd.
B1-MT400 Contents 1 Overview .................................................................................................................................................................3 1.1 Operation Instructions of Manual .................................................................................................................3 1.2 Overview ......................................................................................................................................................3 1.
B1-MT400 1 Overview 1.1 Operation Instructions of Manual 1.1.1 It is not allowed to print or disclose any content of this Manual, including pictures and audio products, under any name without the consent of Huchuang Union; 1.1.2 The equipment operator may copy some sections of this Operation Manual for internal use only, such as for instructing the user how to deal with emergencies. These sections are clearly listed in the catalogue of this manual; 1.1.3 Wuhan Huchuang Union Technology Co., Ltd.
B1-MT400 1.3.4 Power adapter (input: AC100V ~ 240V, 50/60Hz; output: 5V, 2.1A, 10.5W); 1.3.5 No metal objects around the equipment (Keep it away from metal wall). 1.4 Environmental Protection Instructions 1.4.1 MT400 device contains reusable materials, and some components can be recycled after being cleaned and sterilized. 1.4.2 During recycling and handling MT400 device, it is recommended that the company's technical personnel dismantle it and recycle it according to different waste groups; 1.4.
B1-MT400 Push-type buttons; set or modify the equipment parameters through button operations.
B1-MT400 Weight Transmission method Wireless Work frequency 433MHz Transmission distance Power failure alarm Battery Display screen No more than 1200 m in open area, no more than 300 m inside buildings Audible and visual alarm 1000mAh, providing the power supply for more than 2 hours after power failure in fully charged state 2.42 inches O2 concentration test range 0~30% O2 concentration test accuracy ±0.2% CO2 concentration test range 0~0.5% CO2 concentration test accuracy ±0.
B1-MT400 Power wire 1 Antenna 1 Warranty card 1 Certificate of Conformity 1 Operation Manual 1 Packing List 1 Magic tape 75mm*25mm,8pcs 3.2 Precautions before Installation Before installation, please check the Parts List to ensure that the parts are complete; Check whether the product is damaged. The transmission distance of MT400 should be limited and not exceed 3 rooms indoor. 3.3 Installation Method 3.3.
B1-MT400 Note: Try to keep the antenna away from metal objects, otherwise the transmission of wireless signals will be affected. 3.3.2 Wall-Mounting Select a relatively open smooth wall, paste 4 pieces of MT400 special magic tapes on the wall, and then paste another 4 pieces of MT400 special magic tapes on the baseplate of MT400, and then stick magic tapes together. Note: Try to keep the antenna away from metal objects, otherwise the transmission of wireless signals will be affected. 3.
B1-MT400 3.5 Main Interface Instructions Key 1: UP key Key 2: DOWN key Key 1 Key 2 Key 3: "INFO" key: Press this key to enter "System information interface" to view the relevant information on the equipment; Key Key 4 3 Key 4: "MENU" key: Press this key to enter "Setting interface" to set the equipment parameters; Interface: The main interface will pop up after the device is started up.
B1-MT400 The power supply status of the adapter is shown as follows: "OK" indicates that the power supply of the adapter is normal; "ERR" indicates that the power supply of the adapter is abnormal, and there is an audible and optical alarm (sound: The buzzer beeps; light: the icon blinks); Current environmental oxygen concentration; Current environmental carbon dioxide concentration; Current environmental temperature and humidity; Current environmental atmospheric pressure; Current environmental VOC; Curre
B1-MT400 below: Display Instructions: "Model" in Row 1 "SN" in Row 2 Row 6 and 7: Version Equipment model; Unique serial number of equipment; Software/ hardware version of equipment; Operation Instructions of Buttons: Key 1: The system returns to the main interface when the key is pressed; Key 2: The system returns to the main interface when the key is pressed; Key 3: The system returns to the main interface when the key is pressed; Key 4: The system returns to the main interface when the key is pressed
B1-MT400 3.7.2 "1.SET DATE TIME" Note: This option is used for setting the current operating date and time of the equipment; Select "1.SET DATE TIME" on the setting menu, and then press the "OK" button (Key 3) to enter the setting interface.
B1-MT400 3.7.3 "2.SET TEMP" Note: This option is used for temperature calibration; Select "2.SET TEMP" on the setting menu, and then press the "OK" button (Key 3) to enter the setting interface. As shown in the following figure: Operation Instructions of Buttons: Key 1- "+" key: Press this button to add the calibration value by 0.1 ℃ and press and hold this button to add the calibration value by 1 ℃; Key 2- "-" key: Press this button to reduce the calibration value by 0.
B1-MT400 Operation Instructions of Buttons: Key 1- "+" key: Press this button to add the calibration value; Key 2- "-" key: Press this button to reduce the calibration value; Key 3- "OK" key: When you press the button, the device will perform calibration and the system will automatically save parameters and return to the setting interface; Key 4 - "EXIT" key: When you press the button, the system directly returns to the setting interface. Note: Only single point humidity calibration is available. 3.7.5 "4.
B1-MT400 Key 3- "OK" key: When you press the button, the device will perform calibration and the system will automatically save parameters and return to the setting interface; Key 4 - "EXIT" key: When you press the button, the system directly returns to the setting interface. Note: This device supports two-point O2 calibration, namely 0% and 21%. 3.7.6 "5.SET VOC" Note: This option is used for VOC calibration; Select "5.
B1-MT400 Operation Instructions of Buttons: Key 1- "+" key: Press this button to add the set value; Key 2- "-" key: Press this button to reduce the set value; Key 3- "OK" key: When you press the button, the system will automatically save parameters and return to the setting interface; Key 4 - "EXIT" key: When you press the button, the system directly returns to the setting interface. 4 Notices for Use of Equipment Do not use it in the environment below 0℃.
B1-MT400 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 15.105 Information to the user.
B1-MT400 Wuhan Huchuang United Technology Co., Ltd. Address: No.1 Workshop, 1F, Building B10, Wuhan Hi-Tech Medical Device Park, No.