AROYA
18362-00 2.24.2020 TABLE OF CONTENTS 1. Introduction............................................................................................... 1 2. Operation.................................................................................................... 3 2.1 Installation................................................................................................. 3 3. System.......................................................................................................... 7 3.
Data to Cloud Data transmitted from Router to Gateway Gateway (H210) Data transmitted from Sensor Nose to Router Router (H110) Sensor Nose (H311) Data transmitted from Sensor to Gateway Sensor Nose (H311) Sensor Nose (H311) Sensor Nose (H311) Sensor Nose (H311) Data transmitted from Sensor Station to Gateway Data transmitted from Climate Router Data transmitted from Sensor Station to Router Climate Router Climate (H111) Sensor Station (H310) Sensor Station (H310) Sensor Station (H310) Sensor
1. INTRODUCTION Thank you for choosing the AROYA system from METER Group, Inc. USA. Prior to use, verify the sensor arrived in good condition. The AROYA Gateway (H210—Figure 5 and Figure 6) is powered over a Power Over Ethernet (POE) enabled device that is compliant with IEEE 802.3af Power Over Ethernet standards.
INTRODUCTION G R S R S R R S S S S S S S S S S S S G—Gatway R—Router/Router Climate S—Sensor Station/Nose S R S S S S S S S S S S S S S S Figure 1 AROYA system Bluetooth mesh network example 2 S
AROYA 2. OPERATION Please read all instructions before operating the AROYA to ensure it performs to its full potential. PRECAUTIONS METER sensors are built to the highest standards, but misuse, improper protection, or improper installation may damage the sensor and possibly void the manufacturer’s warranty. Before integrating AROYA into a system, make sure to follow the recommended installation instructions and have the proper protections in place to safeguard sensors from damage. 2.
OPERATION Table 1 Mounting H210 Gateway Installation (continued) METER recommends mounting the Gateway on a wall with the cable ports at the bottom. Punch holes in the bottom of the mounting bracket. Make the holes large enough to countersink the screws so the heads are below or flush with the bracket surface. Use a cordless drill with screwdriver attachments to screw the mounting bracket to the wall.
AROYA Follow the steps listed in Table 3 to set up the AROYA Router Climate. Table 3 Router Climate (H111) Installation Grow light hanger (e.g., rope ratchet clip hanger) Tools Needed Chain/cable/rope Preparation Consider the Surroundings METER recommends installing the Router Climate in the center of each room of the greenhouse to facilitate quality communication to the Gateway. The Router Climate should be in an area where the environment is as consistent as possible.
OPERATION Table 4 H311 Sensor Station Installation (continued) Connecting Connect Router to Internet and Verify The Sensor Station is shipped to the customer in SLEEP mode, indicated by a solid red STATUS LED light. To wake the Sensor Station up, press the button (Figure 9) one, two, or three times to trigger the green LED. The device has enetered the ON mode when the STATUS LED shows solid green. NOTE: The unit toggles between ON and SLEEP mode after the button is pressed three times.
AROYA 3. SYSTEM This section describes the specifications, components of the AROYA Gateway, Router, Router Climate, Sensor Station, and Sensor Base. 3.1 SPECIFICATIONS MEASUREMENT SPECIFICATIONS ATMOS 14 Temperature and Relative Humidity (RH) Sensor Relative Humidity (RH) Range 0–100% RH (0.00–1.00) Resolution 0.1% RH Accuracy Sensor measurement accuracy is variable across a range of RH. Refer to the chart in Figure 2.
SYSTEM Accuracy Sensor measurement accuracy is variable across a range of temperatures. Refer to the chart in Figure 3. Figure 3 Temperature sensor accuracy Equilibration Time (τ, 63%) <400 s (response time in 1 m/s air stream Long-Term Drift <0.04 °C/year, typical Vapor Pressure Range 0–47 kPa Resolution 0.01 kPa Accuracy Sensor measurement accuracy is variable across a range of temperatures and RH. Refer to the chart in Figure 4.
AROYA TEROS 12 Soil Moisture, Temperature, and Electrical Conductivity (EC) Sensor Volumetric Water Content (VWC) Range Mineral soil calibration 0.00–0.70 m3/m3 Soilless media calibration 0.0–1.0 m3/m3 Apparent dielectric permittivity (εa ) 1 (air) to 80 (water) NOTE: The VWC range is dependent on the media the sensor is calibrated to. A custom calibration will accommodate the necessary ranges for most substrates. Resolution 0.001 m3/m3 Accuracy Generic calibration ±0.
SYSTEM COMMUNICATION SPECIFICATIONS Output Gateway Ethernet (POE) Wireless communication Bluetooth mesh (Gateway, Routers, Sensors) Sensor types SDI-12 based Antenna Manufacturer Raltron Model number RST-W2-P-110-SMA-H Gain 4.15 dBi vertically polarized, dipole professionally installed NOTE: This radio transmitter IC-5123A-MGM12P0 has been approved by Innovation, Science and Economic Development Canada to operate with the antenna types listed below, with the maximum permissible gain indicated.
AROYA ATMOS 14 with radiation shield Diameter 10 cm (3.94 in) Height 8.5 cm (3.35 in) Sensor Station Length 23.5 cm (9.25 in) Width 18.0 cm (7.48 in) Height 12.3 cm (4.84 in) TEROS 12 Length 9.4 cm (3.70 in) Width 2.4 cm (0.95 in) Height 7.5 cm (2.95 in) Needle length 5.5 cm (2.17 in) Sensor Station Length 6.99 cm (2.75 in) Width 18.00 cm (7.10 in) Height 3.02 cm (1.19 in) TEROS 12 Length 9.4 cm (3.70 in) Width 2.4 cm (0.95 in) Height 7.5 cm (2.95 in) Needle length 5.5 cm (2.
SYSTEM Connector Types Gateway power RJ 45 Ethernet cable Router power RJ 45 Ethernet cable Sensor Station/ Sensor Nose power RJ 45 Ethernet cable ATMOS 14 and TEROS 12 M8 circular female plug and female thread (Sensor State/ sensor connection Sensor Nose, Router, Router Climate) Communications port M8 circular female plug and female thread (Sensor State/ Sensor Nose, Router, Router Climate) ELECTRICAL CHARACTERISTICS Power Lithium-ion (Li-on) rechargeable battery Battery cannot be replaced by the
AROYA The Gateway operates using the following components: • Power over Ethernet (POE) module for continuous power • 2.4-GHz Bluetooth low-energy chip antenna Antenna Front/top cover (end cap) LED indicates active internet connection (flashing orange) NOTE: If the internet connection is slow, the light may flash green instead of orange. This also indicates active connection.
SYSTEM Back/bottom cover (end cap) Red LED indicates power status Antenna Figure 6 AROYA Gateway—back/bottom view 3.2.2 ROUTER (H110) AND ROUTER CLIMATE (H111) The AROYA Router/Router Climate receives data from the sensor stations and transmits data to the gateway wirelessly. The Router acts as a range extension for the network and funnels the data to the Gateway device. The Router operates on a Bluetooth Mesh network and relies on an active POE connection to supply power to the device.
AROYA Blue LED indicates power ON Front/top cover (end cap) Ethernet POE port (RJ 45) Antenna Figure 7 M8 connectors AROYA Router—front/top view The AROYA Router Climate receives data from the Sensor Stations/Sensor Noses and transmits data to the Gateway wirelessly. The ATMOS 14, located in a radiation shield and attached to the Router Climate, collect microclimate data that is also transmitted to the Gateway. The radiation shield comprises a mounting bracket and seven discs.
SYSTEM Solar panel ATMOS 14 in radiation shield Router M8 connectors Antenna Figure 8 AROYA Router Climate with ATMOS 14 sensor 3.2.3 SENSOR STATION (H310) AND SENSOR NOSE (H311) Figure 9 and Figure 10 show the AROYA Sensor Station and Figure 11 and Figure 12 show the AROYA Sensor Nose.
AROYA Antenna TEROS 12 sensor Solar panel Fuction button Figure 9 AROYA sensor station with TEROS 12 sensor 17
SYSTEM Sensor port Serial communications port Antenna connection Figure 10 AROYA sensor station connections—bottom view The AROYA Senosr Nose is another version of the station with a different form factor allows the TEROS 12 prongs to be inserted into the side of slabs of soil. The Sensor Nose is powered with a lithium-ion battery that is solar charged.
AROYA Antenna Function button Solar panel Serial communications port Figure 11 Sensor port AROYA sensor nose—top view Serial label Antenna Sensor port connection Figure 12 Serial communications port AROYA sensor nose—bottom view 19
SERVICE 4. SERVICE This section describes the calibration and maintenance of the AROYA. Troubleshooting solutions and customer support information are also provided. The AROYA Sensor Station, Sensor Nose, Router, and Router Climate, and Gateway should be returned to METER in the event that it quits working for any reason or if the battery no longer holds a charge. Please refer to Section 4.2 for instructions for returning the product to METER. 4.
AROYA 4.3 TROUBLESHOOTING Table 6 lists common problems and their solutions. If the problem is not listed or these solutions do not solve the issue, contact Customer Support. Table 6 Troubleshooting Problem Possible Solutions GATEWAY Check that the device is powered on by observing the red light is on. Confirm internet connectivity through the orange flashing light. ROUTER and ROUTER CLIMATE Check that the device is powered on (solid red light).
SERVICE EUROPE Customer service representatives are available for questions, problems, or feedback Monday through Friday, 8:00 to 17:00 Central European time. Email: support.europe@metergroup.com sales.europe@metergroup.com Phone: +49 89 12 66 52 0 Fax: +49 89 12 66 52 20 Website: metergroup.
AROYA Appendix A. COMPLIANCE CERTIFICATIONS A.1 USA CAUTION: This marking indicates that the user should read all included documentation before use. Users of this product are cautioned to use accessories and peripherals approved by METER Group, Inc. USA. The use of accessories other than those recommended, or changes to this product that are not approved by METER Group, may void the compliance of this product and may result in the loss of the user’s authority to operate the equipment.
Appendix A U.S.A. DIGITAL EMISSIONS COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AROYA BATTERY RECYCLING INFORMATION This product contains or uses a lithium-ion (Li-ion) main battery. When the battery reaches the end of its useful life (no longer holds a charge), the user should return the Sensor Station, Sensor Nose, Router, or Router Climate to METER Group, Inc. USA. Do not mix this battery with the solid waste stream. Contact Customer Service for return information. A.2 CANADA CAUTION: This marking indicates that the user should read all included documentation before use.
Appendix A FCC § 15.19 LABELING REQUIREMENTS This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. FCC § 15.
AROYA Cet équipement génère, utilise et peut émettre de l'énergie de radiofréquence et, s'il n'est pas installé et utilisé conformément au manuel d'instructions, peut provoquer des interférences nuisibles aux communications radio. Le fonctionnement de cet équipement dans une zone résidentielle est susceptible de provoquer des interférences nuisibles, auquel cas l'utilisateur devra corriger les interférences à ses propres frais. U.S.A.
Appendix A DÉCLARATION CLASSE A DU CANADA Cet appareil numérique de la Classe A est conforme à toutes les exigences du Règlement canadien sur les équipements causant des interférences. RADIO PRECAUTION STATEMENT Radio transmitters IC-5123A-MGM12P0, IC-25859-H110A00, and IC-25859-H310A00 have been approved by Innovation, Science, and Economic Development Canada to operate with the antenna types listed below, with the maximum permissible gain indicated.
AROYA BATTERY RECYCLING INFORMATION This product contains or uses a lithium-ion (Li-ion) main battery. When the battery reaches the end of its useful life (no longer holds a charge), the user should return the Sensor Station, Sensor Nose, Router, or Router Climate to METER Group, Inc. USA. Do not mix this battery with the solid waste stream. Contact Customer Support for return information. CAUTION: consultez les instructions de la batterie. Aucune pièce réparable par l'utilisateur.
18367-00 2.24.2020 METER Group, Inc. USA 2365 NE Hopkins Court Pullman, WA 99163 T: +1.509.332.2756 F: +1.509.332.5158 E: info@metergroup.com W: metergroup.com METER Group AG Mettlacher Straße 8, 81379 München T: +49 89 1266520 F: +49 89 12665220 E: info.europe@metergroup.com W: metergroup.de © 2020 All Rights Reserved.