R R-NZ R ENGLISH GV60 Bidirectional Control System for use with The Puck and Symax© Handsets together with myfire© App Installation and Operating Instructions APPLICATION AND COMPONENTS Application ................................................................................. 3 Components .............................................................................. 3 GV60 – GAS COMBINATION CONTROL Technical Data ...........................................................................
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY IMPORTANT SAFETY INFORMATION Read these instructions carefully and completely before installing or operating. Failure to follow them could result in a fire or explosion causing property damage, personal injury, or loss of life. Service and installation must be performed by a trained / experienced service technician. WHAT TO DO IF YOU SMELL GAS ▪ Do NOT operate any appliance.
DRAFT INSTALLATION AND OPERATING INSTRUCTIONS FOR OEM USE ONLY APPLICATION AND COMPONENTS APPLICATION GV60 is a battery-powered electronic remote ignition and control system for gas appliances with pilot burners and ODS systems. COMPONENTS 8-button handset B6R-H8(A)TL3P...D The Puck B6R-H8(A)SP... 10-button handset B6R-H8(A)TV...P...D Wall Switch EU G6R-ZWSE… Wall Switch US G6R-ZWSN..-... Switch Panel with cable G6R-SPKS / 1000 ENGLISH with integrated Touchpad G6R-TPN...
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY GV60 – GAS COMBINATION CONTROL APPROVALS CSA: Multifunctional gas control according to ANSI Z21.78 6.20 and ANSI Z21.20 6.20 for U.S. & Canada CE: Gas Appliances Regulation 2016/426/EU and DIN EN 298, DIN EN 126, DIN EN 13611, 2014/53/EU (RED) FUELS CSA: Suitable for natural, manufactured, mixed gases, liquefied petroleum gases, and LP gas-air mixtures. CE: Suitable for use with gases of EN 437 gas family 1, 2 and 3.
DRAFT Drop PIPED GAS SUPPLY Horizontal Gas Control Gas Control 3 inch (76 mm) minimum Riser PIPED GAS SUPPLY Sediment Trap Drop TUBING GAS SUPPLY Horizontal 3 inch (76 mm) minimum Sediment Trap Gas Control Riser 3 inch (76 mm) minimum Sediment Trap Figure 8: Sediment Trap (where required) MOUNTING POSITION I n upright position, gas control knobs are on top of the valve. Valve may be mounted 0° to 90° any direction (including vertical) from the upright position.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY NOTICE Do NOT use if leakage is detected. There is a danger of fire or explosion depending on conditions. WIRING (see figures 28-32, pages 26-30) Connect all components according to the appropriate wiring diagram. ▪ When GV60 components are installed, make sure they are not exposed to dirt, oil, grease or other chemical agents. ▪ Do not permit foreign particles under plastic cover.
DRAFT To avoid damaging the electronics, do NOT use metal tools to remove the batteries from the handset / receiver. ▪ Without using a mains adapter, battery replacement is recommended at the beginning of each heating season. ▪ Old or dead batteries should be removed immediately. If left in the unit the batteries can overheat, leak, and / or explode. ▪ Do NOT expose batteries (including during storage) to direct sunlight, excessive heat, fire, moisture, or severe impact.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY KNOB SETTINGS ⅜ to ½ in. Knobs function as follows (see figure 14, page 8): KNOB Main valve knob Main valve knob POSITION (10 to13 mm) FUNCTION OFF Prevents main gas flow through valve. ON Permits main gas flow through valve if the pilot is lit and thermocouple is generating sufficient power. Manual knob MAN Manual knob ON Allows the pilot to be manually ignited and prevents main gas flow. Allows for automatic ignition.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY that no gas is in the area around the appliance, including near the floor. If you detect gas STOP! Follow “What to do if you smell gas” in the safety information (see page 2). If no gas is present, proceed according to the Mertik Maxitrol Operating Instructions. Fire or Explosion Hazard. Attempted disassembly or repair can cause property damage, severe injury or death.
INSTALLATION AND OPERATING INSTRUCTIONS Piezo Ignitor (optional) ON / OFF Switch (optional) in ON Position 8 Wire Receiver Jack DRAFT Connection Piezo Ignitor Tab 2.8 x 0.8 mm MANUAL Knob in MAN Position Manual Pilot Valve Operator Microswitch Main Valve Knob in OFF Position FOR OEM USE ONLY On-Demand pilot ▪ CSA: 7 Day Shut-Off CE: 5 Day Shut-Off ▪ This green feature eliminates gas energy consumption during extended appliance inactivity.
DRAFT TOUCHPAD / WALL SWITCH SWITCH PANEL Increase flame height A) Increase flame height ON / OFF B) ON / OFF Decrease flame height C) Decrease flame height Figure 19: Touchpad / Wall Switch Figure 20: Switch Panel AMBIENT TEMPERATURE RANGE CSA: Wall Switch / Touchpad: 176 °F CE: Wall Switch / Touchpad: 80 °C AMBIENT TEMPERATURE RANGE CSA: Switch Panel: 221 °F CE: Switch Panel: 105 °C To Turn ON Appliance ▪ Press button (see figure 19, page 11) until two short beeps (CE version) or continuous
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY SYMAX HANDSET AMBIENT TEMPERATURE RANGE CSA: Handset: 32 °F to 131 °F CE: Handset: 0 °C to 55 °C RADIO FREQUENCY CSA: 918.0 MHz for U.S. (FCC), Canada (ISED), New Zealand (RNZ) and Australia (ACMA) (handset, receiver) CE: 868.1 MHz for Europe (handset, receiver) (see general radio frequency information on page 4.) RADIATED POWER OUTPUT CSA: 90.8 µV/m CE: -3.5 dBm POWER SUPPLY Handset: 2 x 1.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY 8-BUTTON OPERATION Child Proof Time Signal Indicator Thermostatic Mode Battery Status AM PM ENGLISH Countdown Timer Fahrenheit or Celsius ON OFF Program Mode Eco Mode 1 2 Temperature 2nd Burner Feature Figure 21: 8-button Display SETTING FAHRENHEIT OR CELSIUS AM PM ▪T o change between °C and °F, press and buttons simultaneously. NOTE: C hoosing °F results in a 12 hour clock. Choosing °C results in a 24 hour clock.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT MANUAL MODE (HANDSET) FOR OEM USE ONLY DESIGNATED LOW FIRE AND HIGH FIRE NOTICE BEFORE OPERATING 1. Make sure MANUAL knob on the GV60 valve is in the ON, full counterclockwise position. 2. Place the ON / OFF switch (if equipped) in the I (ON) position. AM ▪ To go to low fire, double-click ton. ▪ is displayed. but- NOTE: F lame goes to high fire first before going to low fire.