INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY 10-BUTTON OPERATION Child Proof Time Signal Indicator Thermostatic Mode Battery Status AM PM ENGLISH Fan Countdown Timer Fahrenheit or Celsius Program Mode Light ON OFF 1 2 Eco Mode Temperature 2nd Burner Feature Figure 22: 10-button Display SETTING FAHRENHEIT OR CELSIUS AM PM ▪T o change between °C and °F, press and buttons simultaneously. NOTE: C hoosing °F results in a 12 hour clock.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT MANUAL MODE (HANDSET) FOR OEM USE ONLY DESIGNATED LOW FIRE AND HIGH FIRE NOTICE BEFORE OPERATING 1. Make sure MANUAL knob on the GV60 valve is in the ON, full counterclockwise position. 2. Place the ON / OFF switch (if equipped) in the I (ON) position. AM ▪ To go to low fire, double-click ton. ▪ is displayed. but- NOTE: F lame goes to high fire first before going to low fire.
DRAFT MODES OF OPERATION AM PM ON OFF 1 2 AM PM ON OFF Thermostatic Mode he room temperature is measured and T compared to the set temperature. The flame height is then automatically adjusted to achieve the set temperature. FOR OEM USE ONLY PROGRAM MODE AM PM ON OFF AM PM ON OFF 1 2 AM Eco Mode Flame height modulates between high and low. If the room temperature is lower than the set temperature, the flame height stays on high for a longer period of time.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT 2ND BURNER FEATURE SELECTED AM PM ON OFF 1 2 FOR OEM USE ONLY ON TIME SETTING (PROGRAM 1): 7. , , is displayed, is displayed shortly, and hour flashes. 8. To select hour press or button. 9. To confirm press button. , , is displayed, displayed shortly, and minutes flash. 10. To select minutes press or button. 11. To confirm press button.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY LIGHT / DIMMER OPERATION AM ON: ▪ Press button ( is displayed). ▪ Light is ON at preset level. OFF: Press button ( disappears). ENGLISH SETTING: 1. Press button and hold until flashes. 2. To adjust light between 20…100 % press or button. 3. To confirm setting either press button or wait ( is displayed). NOTE: The Light works independently of the pilot flame. If you want the light on but no flame, press button.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY THE PUCK HANDSET TECHNICAL DATA SYNCHRONIZATION RECEIVER / THE PUCK HANDSET NOTICE AMBIENT TEMPERATURE RANGE CSA: The Puck: 32 °F to 131 °F CE: The Puck: 0 °C to 55 °C See page 7 for more information about synchronization between receiver and The Puck. RADIO FREQUENCY CSA: 918.0 MHz for U.S. (FCC), Canada (ISED), New Zealand (RNZ) and Australia (ACMA) (The Puck, receiver) CE: 868.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY MYFIRE WI-FI BOX (B6R-W2…) TECHNICAL DATA Receiver WLAN LED 1 LED 2 AMBIENT TEMPERATURE RANGE 32 °F to 176 °F / 0 °C to 80 °C RGB 1 RGB 2 RGB Power Input Receiver cable RADIATED POWER OUTPUT 19.8 dBm POWER SUPPLY 6 VDC powered by the receiver WIRELESS COMMUNICATION ▪ WPA2 authentication ▪ AES 256-bit encryption security ▪ Compatible with IEEE 802.11 b/g/n POWER CONSUMPTION Nominal: max. 0.5 W Standby: max. 0.
DRAFT INSTALLATION AND OPERATING INSTRUCTIONS FOR OEM USE ONLY MYFIRE WI-FI BOX (B6R-W2…) RGB LED'S AND LED DRIVER TECHNICAL DATA Indirect connection ( >5 A) ▪ 5 - 24 VDC direct from the LED driver to the LEDs ▪ Connection of data output (DO) and ground (GND) from the LED RGB control output of the Wi-Fi Box to the RGB LEDs. (see figure 26, page 24) RGB LED WORKING VOLTAGE RANGE 5 - 24 VDC SUPPORTED RGB LED COUNT PER RGB-CHANNEL 300 NOTICE There is no standard for RGB LED controller.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY MYFIRE APP SETUP NOTICE For myfire App setup, you will need your Wi-Fi network SSID and password. USE RETRY IF PASSWORD IS INCORRECT 1. Touch the "Retry" button to repeat the Kwik Connect process. 2. Type in the correct password. INITIAL SETUP 1. Download myfire App from Apple App Store or Google Play Store. 2. Touch screen to start App setup. 3. Choose language, temperature (°C or °F) and time format (12 or 24 hour).
26 / 30 Interrupter Block G60-ZUSV… Ignition Cable G60-ZKIS… Pilot Burner G30-ZP2M-L Antenna Receiver B6R-R8P, B6R-RAP Combination Control GV60… The receiver B6R-R8(A)PT… has main burner supervision (2nd thermocouple option). This option is programmed so that it cannot be used without the second thermocouple installed and vice versa.
NOTE: To connect LED lights or 12 V lamps a driver/ transformator is needed. The appliance manufacturer must test levels with fan. Levels may vary with fan characteristics. Max. AWG 12 / 2.5 mm2 1 2 1 2 1 2 V Module G6R-BUMV3 V Module G6R-BEAV3 Cable V Module-Receiver G6R-CBV… Receiver B6R-R8P, B6R-RAP Combination Control GV60… ENGLISH For more information see instructions GV-S60-II-EN.DE.FR.NL… or consult Mertik Maxitrol.
28 / 30 NOTICE Connection of a 2nd thermocouple ▪A 2nd thermocouple is placed in the main burner to check that the main gas is ignited within a certain time after opening. ▪ The voltage is measured for 22 sec (PT) or 29 sec (PT2) after the motor has turned to high fire (during ignition and after increasing flame height). If the voltage is lower than 1.8 mV, the electronics shut off the gas flow.
Fan Mains Power (115 / 230 V; AC) Fan Light Pilot Burner G30-ZP2M-L Main Burner 1 V Module G6R-BEAV3/G6R-BUMV3 Relay with Cable (volt-free contact) G6R-CL40 (50 V / 0.6 A) G6R-CLB40 (240 V / 5 A) Main Burner 2 Wall Switch (optional) G6R-ZWSE(N)… DOWN ON-OFF UP Figure 31 29 / 30 ENGLISH ▪ Power Flue Control, solenoid valve, fan and pressure switch are not available from Mertik Maxitrol. The Power Flue Control operates the fan and the solenoid valve and checks the pressure switch.
30 / 30 Symax Handset (optional) B6R-H8(A)...P...D... OR The Puck – Handset (optional) B6R-H8(9)SP... REQUIRED HANDSET Cable G6R-CBV... Provided by OEM. RGB 1 Phoenix, MC 1.5/3-ST-3.5 Interrupter Block G60-ZUSV... RGB Power Input LED Driver / Transformer 5 V - 24 V DC / 5 A WS2811 / 12 Standard myfire Wi-Fi Box B6R-W2(XX)-(2)-(T) Cable G60-ZCSW2... Receiver B6R-R8P(T)(T2), B6R-RAP, B6R-RAPT, B6R-RAPT2 Gas Combination Control GV60... RGB 2 Phoenix, MC 1.5/3-ST-3.
INSTALLATION AND OPERATING INSTRUCTIONS © 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
INSTALLATION AND OPERATING INSTRUCTIONS FOR OEM USE ONLY © 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
R Exclusive Distributor Europe for Maxitrol Company Exclusive Distributor North America for Mertik Maxitrol Mertik Maxitrol GmbH & Co. KG Warnstedter Str. 3, 06502 Thale GERMANY Maxitrol Company 23555 Telegraph Rd., PO Box 2230 Southfield, MI 48037-2230 USA Tel: + 49 3947 400-0 Fax: + 49 3947 400-200 www.mertikmaxitrol.com GV60-II.OI-EN-04.2019 Tel: + 1 248-356-1400 Fax: + 1 248-356-0829 www.maxitrol.com © 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.