R R DRAFT February 14, 2019 ENGLISH GV60 Bidirectional Control System for use with The Puck and Symax© Handsets together with myfire© App Installation and Operating Instructions
R R ENGLISH GV60 Bidirectional Control System for use with The Puck and Symax© Handsets together with myfire© App Installation and Operating Instructions APPLICATION AND COMPONENTS Application ................................................................................. 3 Components .............................................................................. 3 GV60 – GAS COMBINATION CONTROL Technical Data ...........................................................................
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY IMPORTANT SAFETY INFORMATION Read these instructions carefully and completely before installing or operating. Failure to follow them could result in a fire or explosion causing property damage, personal injury, or loss of life. Service and installation must be performed by a trained / experienced service technician. WHAT TO DO IF YOU SMELL GAS ▪ Do NOT operate any appliance.
DRAFT INSTALLATION AND OPERATING INSTRUCTIONS FOR OEM USE ONLY APPLICATION AND COMPONENTS APPLICATION GV60 is a battery-powered electronic remote ignition and control system for gas appliances with pilot burners and ODS systems. COMPONENTS 8-symbol handset B6R-H8(A)TL3P...D 10-symbol handset B6R-H8(A)TV...P...D Wall Switch EU G6RZWSE… with integrated Touchpad G6R-TPN... Wall Switch / Touchpad Cable G6R-CWSN… Switch Panel with cable G6R-SPKS / 1000 ENGLISH The Puck B6R-H8(A)SP...
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY GV60 – GAS COMBINATION CONTROL TECHNICAL DATA APPROVALS CSA: Multifunctional gas control according to ANSI Z21.78 6.20 and ANSI Z21.20 6.20 for U.S. & Canada CE: Gas Appliances Regulation 2016/426/EU and DIN EN 298, DIN EN 126, DIN EN 13611, 2014/53/EU (RED) FUELS CSA: Suitable for natural, manufactured, mixed gases, liquefied petroleum gases, and LP gas-air mixtures. CE: Suitable for use with gases of EN 437 gas family 1, 2 and 3.
DRAFT 1. Turn off gas supply at the appliance service valve before starting installation, and perform a Gas Leak Test after the installation is complete. 2. Install the sediment trap or filter (where required) in the gas supply line to prevent contamination of the gas valve (see figure 8, page 5). 3. Use only your hand to push in or turn the gas control knobs. Never use tools. If a knob will not push in or turn by hand, do not try to repair it. Call a qualified service technician.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT The control valve must be in the closed position when the gas supply line is tested for leakage up to 150 mbar (15 kPa; 2 PSI). Above 150 mbar (15 kPa; 2 PSI) the control valve must be isolated from the gas supply. PERFORM PRESSURE TEST 1. Check carefully for gas leaks immediately after the valve has been installed and the gas turned on. Do this before attempting to operate the appliance or other gas burning device. 2.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT NOTICE The antenna (see page 25) must not cross or come into contact with the ignition wire. This will render the receiver inoperable. FOR OEM USE ONLY the synchronization and data exchange is in process (see figure 13, page 7). Two (2) short beeps confirm the code is set. After successful synchronization the current state of the gas fire is displayed on the handset.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY V MODULE POWER SUPPLY CSA: Inlet: Outlet: Built-in fuse: CE: Inlet: Outlet: Built-in fuse: Pilot Gas Adjustment Screw (turn with screwdriver) Pressure Regulator (remove plug first) 115 VAC / 60 Hz; 210 VA 115 VAC / 60 Hz; 100 VA each 2.5 A 230 VAC / 50 Hz; 210 VA 230 VAC / 50 Hz; 100 VA each 2.5 A Manual Knob Main Valve Knob Connection Piezo Igniter Tab 2.8 x 0.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY Figure 16: Combination Control GV60, Cover NOTE: Throttle model’s pressure is increased by turning counterclockwise ; or decreased by turning clockwise . 4. After adjustment, replace the plug. 5. If no other adjustments are required, close pressure tap(s) by turning the screw(s) full clockwise . Check all connections / pressure tap(s) for leaks. 6.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT 6. Place ON / OFF switch (if equipped) in I (ON) position. 7. With the MANUAL knob in MAN position a manual pilot valve operator and piezo ignitor (optional) are accessible. 8. Fully push down manual pilot valve operator and hold in, to start pilot gas flow (see figure 18, page 10).
DRAFT TOUCHPAD / WALL SWITCH SWITCH PANEL Increase flame height A) Increase flame height ON / OFF B) ON / OFF Decrease flame height C) Decrease flame height Figure 19: Touchpad / Wall Switch Figure 20: Switch Panel AMBIENT TEMPERATURE RANGE CSA: Wall Switch / Touchpad: 176 °F CE: Wall Switch / Touchpad: 80 °C AMBIENT TEMPERATURE RANGE CSA: Switch Panel: 221 °F CE: Switch Panel: 105 °C To Turn ON Appliance ▪P ress button (see figure 19, page 11) until two short beeps confirm the start sequence
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY SYMAX HANDSET TECHNICAL DATA AMBIENT TEMPERATURE RANGE CSA: Handset: 32 °F to 131 °F CE: Handset: 0 °C to 55 °C RADIO FREQUENCY CSA: 918.0 MHz for U.S. (FCC), Canada (ISED), New Zealand (RNZ) and Australia (ACMA) (handset, receiver) CE: 868.1 MHz for Europe (handset, receiver) (see general radio frequency information on page 4.) POWER SUPPLY Handset: 2 x 1.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY 10-SYMBOL OPERATION Child Proof Time Signal Indicator Thermostatic Mode Battery Status AM PM ENGLISH Fan Countdown Timer Fahrenheit or Celsius Program Mode Light ON OFF 1 2 Eco Mode Temperature Auxiliary Feature (2nd Burner Feature) Figure 22: 10-symbol Display SETTING FAHRENHEIT OR CELSIUS AM PM To change between °C and °F, press and buttons simultaneously. NOTE: Choosing °F results in a 12 hour clock.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT MANUAL MODE (HANDSET) NOTICE BEFORE OPERATING 1. Make sure MANUAL knob on the GV60 valve is in the ON, full counterclockwise position. 2. Place the ON / OFF switch (if equipped) in the I (ON) position. FOR OEM USE ONLY DESIGNATED LOW FIRE AND HIGH FIRE NOTE: B acklight must be on for high fire and low fire double-click operation. AM ▪ To go to low fire, double-click ton. is displayed.
DRAFT MODES OF OPERATION AM PM ON OFF 1 2 AM PM ON OFF Thermostatic Mode he room temperature is measured and T compared to the set temperature. The flame height is then automatically adjusted to achieve the set temperature. FOR OEM USE ONLY PROGRAM MODE AM PM AM AM PM ON OFF ON OFF OFF: 1. Press or or button to enter Manual Mode. 2. Press button to enter Thermostatic Mode. 3. Press button to enter Eco Mode.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT AUXILIARY FEATURE (2ND BURNER FEATURE) ON OFF 1 2 ON TIME SETTING (PROGRAM 1): 7. , , displayed, is displayed shortly, and hour flashes. 8. To select hour press or button. 9. To confirm press button. , , displayed, displayed shortly, and minutes flash. 10. To select minutes press or button. 11. To confirm press button.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY LIGHT / DIMMER OPERATION AM ON: Press button ( on at preset level. OFF: Press displayed). Light is button ( disappears). ENGLISH SETTING: 1. Press button and hold until flashes. 2. To adjust light between 20…100 % press or button. 3. To confirm setting either press button or wait ( displayed). NOTE: The Light works independently of the pilot flame. If you want the light on but no flame, press button.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY THE PUCK HANDSET The Puck is a smart control that works in conjunction with the GV60 / Symax system. Its basic functions include turning the fire on and off and turning the flame height up and down. The Puck is equipped with temperature sensing that allows the use of the popular myfire app.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY MYFIRE WI-FI BOX (B6R-W2…) The second generation of the Wi-Fi Box has a faster processing speed, two RGB outlets, identical connectors on both ends of the cable, and the Wi-Fi Box itself has a much smaller footprint. Receiver WLAN LED 2 LED 1 RGB 1 RGB 2 RGB Power Input Receiver cable TECHNICAL DATA RADIO FREQUENCY 2.4 GHz (see radio frequency information on page 4.
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY MYFIRE APP SETUP NOTICE For more detailed app setup / operating instructions refer to www.myfireapp.com INITIAL SETUP 1. Download myfire app from Apple App Store or Google Play Store. 2. Touch screen to start app setup. 3. Choose language, temperature (°C or °F) and time format (12 or 24 hour). REGISTRATION NOTE: You must register before logging in. Registration is one time only. 1. Fill in data and accept the “Privacy Policy”. 2.
14 to 100 Watt Fan 4 levels from 60 % to 100 % myfire Wi-Fi Box B6R-W2(XX)-(2)-(T) 115/230 V; AC Mains Power Cable G6R-CBV… Provided by OEM. RGB 1 Phoenix, MC 1.5/3-ST-3.5 NOTE: To connect LED lights or 12 V lamps a driver/transformator is needed.
R Exclusive Distributor Europe for Maxitrol Company Exclusive Distributor North America for Mertik Maxitrol Mertik Maxitrol GmbH & Co. KG Warnstedter Str. 3, 06502 Thale GERMANY Maxitrol Company 23555 Telegraph Rd., PO Box 2230 Southfield, MI 48037-2230 USA Tel: + 49 3947 400-0 Fax: + 49 3947 400-200 www.mertikmaxitrol.com GV60-II.OI-EN-02.2019 Tel: + 1 248-356-1400 Fax: + 1 248-356-0829 www.maxitrol.com © 2018 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.