DIGITAL MULTIMETER 600.219 600.
Read this owner’s manual thoroughly before use. SAFETY INFORMATION The digital multimeter has been designed according to IEC-1010 concerning electronic measuring in struments with an over voltage category (CATI) and pollution degree 2. ELECTRICAL SYMBOLS AC (Alternating Current) DC (Direct Current) Important safety information. Refer to the manual. Dangerous voltage may be present. Earth ground Fuse Conforms to European Union directives Double insulated Do not attempt to make any repairs yourself.
WARNING To avoid possible electric shock or personal injury, follow these guidelines: • Do not use the meter if it is damaged. Before you use the meter, inspect the case. Pay particular attention to the insulation surrounding the connectors • Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace damaged test leads before you use the meter. • Do not use the meter if it operates abnormally. Protection may be impaired.
CAUTION To avoid possible damage to the meter or to the equipment under test, follow these guidelines: • Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance. • Use the proper terminals, function, and range for your measurements. • Before measuring current, check the meter's fuses and turn power OFF to the circuit before connecting the meter to the circuit.
FRONT PANEL DESCRIPTION 1. LCD 2. Power Switch 3. Capacitor Measuring Socket 4. Transistor Testing Socket 5. Function Range Switch 6. Temperature Measuring Socket (For 600.219 only) 7.
TECHNICAL SPECIFICATIONS Accuracy is specified for a period of one year after calibration and at 18ºC~28ºC(64ºF~82ºF) with relative humidity up to 75%. Accuracy specifications take the form of: ±([% of Reading]+[Number of Least Significant Digits]) DC VOLTAGE RANGE RESOLUTION 200mV 100µV 2000mV 1mV 20V 10mV 200V 100mV 600V 1V Input impedance: 10M Ω for all ranges AC VOLTAGE RANGE RESOLUTION ACCURACY ±(0.8% rdg +5D) ±(1.0% rdg +5D) ACCURACY 600.219 600.524 ±(1.2% rdg+2D) / 200mV 0.
DC CURRENT RANGE RESOLUTION ACCURACY 600.219 600.524 / ±0.8% rdg+5D) 200µA 0.1µA 2mA 1µA 20mA 10µA 200mA 100µA ±(1.2% rdg+5D) 2A 1mA / 20A 10mA ±(2.0% rdg+5D) Overload protection: 600.219: 250mA/250V fused (Range 10A unfused) 600.524: 2A/250V fused (Range 10A unfused) Maximum input current: 10A (can not last for more than 10 seconds) Measuring Voltage Drop: 200mV AC CURRENT RANGE RESOLUTION ACCURACY 600.219 600.524 200µA 0.1µA ±(1.2% rdg +5D) / 2mA 1µA 20mA 10µA 200mA 100µA ±(1.
RESISTANCE RANGE 200 Ω 2K Ω 20K Ω 200K Ω 2MΩ RESOLUTION 0.1 Ω ACCURACY ±(1.2% rdg+5D) 1Ω 10 Ω 100 Ω 1K Ω ±(1.0% rdg+5D) 20M Ω 10K Ω Open cicuit voltage: less than 700mV. FREQUENCY (For 600.219 only) RANGE RESOLUTION 20KHz 10Hz CAPACITANCE (For 600.219 only) RANGE RESOLUTION 2000pF 1pF 20nF 10pF 200nF 100pF 2µF 1nF 20µF 10nF Measuring Voltage: Approximate 40mV RMS. TRANSISTOR hFE TEST RANGE hFE PNP & NPN 0 ~ 1000 TEST CURRENT Ib ≈ 10µA ±(1.5% rdg+5D) ACCURACY ±(1.0% rdg+4D) ACCURACY ±(5.
TEMPERATURE (For 600.219 only) RANGE Temperature Range RESOLUTION ACCURACY 0ºC ~ 400ºC 1ºC ±(1.5% rdg+5ºC) TEMP. 400ºC ~ 1000ºC 1ºC ±(1.5% rdg+15ºC) Note: Use “K” type thermocouple probe while measuring temperature. DIODE AND AUDIBELE CONTINUITY TEST Range Description Test Condition The approx. forward The forward DC current voltage of the diode is approx. 1mA, the under test will be reversed DC voltage is displayed on the LCD. approx. 2.8V.
DC VOLTAGE MEASUREMENT 1) Connect the red test lead to the "V/Ω" jack and the black test lead to the "COM" jack. 2) Set the Function / Range switch to the desired “ ” range. If the voltage to be measured is not known beforehand, set the switch to the highest range and then turn down range by range until satisfactory resolution is obtained. 3) Connect the test leads to the source or load to be measured. 4) Read the voltage value displayed on the. DC CURRENT MEASUREMENT 1) [600.
DC CURRENT MEASUREMENT 1) [600.219] Connect the black test lead to the "COM" jack and the red test lead to the "mA" jack (While the current to be measured is between 200MA and 20A, remove the red test lead to the “20A” jack.) [600.524] Connect the black test lead to the "COM" jack and the red test lead to the "2A" jack (While the current to be measured is between 2A and 20A, remove the red test lead to the “20A” jack.) 2) Set the Function / Range switch to the desired “ ” range.
DIODE TEST 1) Connect the red test lead to "V/Ω" jack and the black test lead to the "COM" jack (The polarity of the red test lead is positive “+”) 2) Set the Function / Range switch to " " range. 3) Connect the red test lead to the anode of the diode to be tested and the black test lead to cathode of the diode. The approximate forward voltage drop will be displayed on the LCD. If the connection is reversed, only figure "1" will be shown.
TEMPERATURE MEASUREMENT (For 600.219 only) 1) Insert the K type probe to the temperature jack. 2) Set the Function / Range switch to the “ºC” range. 3) Connect the K type probe to the object to be measured. 4) Read Temperature value in displayed on the LCD. AUTO POWER-OFF The function of auto power-off extends the life of the battery by turning the meter off if the range switch has not been operated for about 15 minutes. To turn the meter on again, just rotate the range switch or press the power switch.