39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 39-T1 User Manual Rev. 4.0 Model: 39-T1 Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Table of Content FCC statement..................................................................................................... 3 CE statement ....................................................................................................... 3 Chapter 1 Introduction of 39-T1 ......................................................................... 4 1.1 Overview of 39-T1 ...............................................................................
9-T1 User Manual Rev. 4.0 Updated on 20DEC2016 FCC statement FCC NOTICE: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Chapter 1 Introduction of 39-T1 1.1 Overview of 39-T1: 39-T1 is an UHF EPC C1G2 mobile RFID reader that is cost-effective, reliable and scalable mobile UHF RFID device. Such device would be monitoring the UHF RFID tagged items on the tray’s movement. The 39-T1 Intelligent RFID Reader supports protocols, UHF CLASS 1 GEN2 EPC C1G2/ISO 18000-6C, (865-868 MHz RFID frequency band) in Europe as well as (902-928 MHz RFID frequency band) in United States.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 1.2 Ports Description The 39-T1 has several types of input/output port: Items no. Name Description 1 DC jack 19V/3.42A dc power supply input 2 USB Port One standard USB port 3 Micro USB Port One standard Micro USB port 4 Power On button The DUT is turned On by pressing the button 5 Latch button The latch give the signal to the tray the main battery will be removed Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 1.3 Indicators LEDs in 39-T1 The 39-T1 has different LEDs to indicate the reader status. Items no. Name Description 6 Red LED Charging 7 Blue LED Fully charged battery or normal operation without charging 8 Green LED Indicate the Main Battery can be removed Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 1.4 Antenna for 39-T1 There are two antennas are used in 39-T1. The following antennas are used for 39-T1: Check-in antenna: antenna gain = 0dBi Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Checkout antenna: antenna gain = 0dBi Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 1.5 Specification: Item Input indicator Connectivity UHF RF Output Power Battery Charger Talk/ Standby time Charging time Operation temp. Storage temp. Operating Humidity Features Specification 1 power key button 1 latch key button Red LED stand for charging Blue LED stand for fully battery / normal operation with charging Green LED stand for ready to remove the Main battery Bluetooth 4.0 USB 2.0 Wifi ( 802.11 b/g/n) Max.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Chapter 2 Installation of 39-T1 2.1 Start-up Procedure of 39-T1 This section explains how to set-up 39-T1 and connect the 39-T1 to your computer and antenna: I. Power On the 39-T1 by pressing the Power on button. Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 II. Enter the Window, and then find the test tools or apps to use. Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 III. For using Wifi, selecting and connecting the network in the site. After connected to the network, then use IE browser to connect the internet. Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 IV. For using Bluetooth, searching and connecting the BT device you want. After connected, you can transfer the file or command to the device. Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 V. For using RFID, run the program or apps like “Explorer.exe”. Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 VI. Set the correct COM number in the program which found in the device manager in the tray. Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 VII. Run the program “Explore.exe”. Then set the parameter. i) Set antenna port to 1 ii) Set the Dwell to 400 iii) Set the inventory to 10000 iv) Set the power to 300 VIII. Set the GPIO to configure using check-in antenna or check-out antenna. If we use check-in antenna, then choose “set” and “HI” in pin_1, and then press “apply”. If we use check-out antenna, then choose “set” and “HI” in pin_2, and then press “apply”.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 IX. After setting all parameter, you will see the data logging when placing the tags on the different antenna side. X. 39-T1 operates at UHF frequency band, ranging from 865MHz to 928MHz (ETSI 865-868 MHz, FCC 902-928 MHz, SRRC 920-925 MHz and NCC 922-928 MHz); the setting depends on countries’ regulations. Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 2.2 Environmental Requirements The next table includes environmental requirements for the 39-T1. Choose a location that meets these requirements. Description Minimum Maximum Operating temperature 0ºC 40ºC Storage temperature -20ºC 60ºC Humidity (non-condensing) 20% 90% Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 2.3 Caution Danger of Electric Shock Disconnect the device from the electric supply before cleaning or performing maintenance on the machine. Keep this device dry. Turn off or unplug the machine when it is not in use. Please read the information contained within this user manual prior to attempting installation and operation of the RFID Reader.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 2.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Federal Communications Commission (FCC) Compliance These products operate at the following frequencies in compliance with Part 15 of the FCC rules: RFID; 902 MHz - 928 MHz, Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 FCC criteria. The 39-T1 shall be installed & used such that parts of the user’s body and the hands should be maintained at a comfortable distance of approximately 25 cm or more. In some situations or environments, the use of wireless devices may be restricted by the proprietor of the building or responsible representatives of the organization.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Chapter 3 Demonstration of RFID Applications 3.1 Creating RFID Application with 39-T1 Megabyte Ltd. 39-T1 is an intelligent reader and compliance with EPC global C1G2/ISO 18000-6C, Users can develop own UHF RFID application on this platform. 3.1.1 Delivering Application to 39-T1 When the user wants to deliver applications to the 39-T1, they just simply install the program in Windows. 3.1.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Chapter 4 Regulatory Information 4.1 Federal Communications Commission (FCC) Compliance This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 4.2 CE Compliance This device has been tested to and conforms to the regulatory requirements of the European Union and has attained CE Marking. The CE Mark is a conformity marking consisting of the letters "CE". The CE Mark applies to products regulated by certain European health, safety and environmental protection legislation.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Chapter 5 Disclaimer Notice Disclaimer Notice The manufacturer shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. This document contains proprietary information, which is protected by international patent applications and copyright. All rights reserved.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Chapter 6 Warranty 1. Megabyte Ltd warrants to the User that the Products sold to the User will comply with their published specifications and will be of satisfactory quality and that Megabyte Ltd is entitled to sell the Products to the User. Megabyte Ltd warrants that for a period of twelve (12) months from date of purchase (“the Warranty Period”), the products will be free from defects in materials and workmanship. 2.
39-T1 User Manual Rev. 4.0 Updated on 20DEC2016 Chapter 7 Support Technical support/Sales Enquiry can be obtained from Megabyte Ltd. Please email to: jimmywong@myndar.com Technical Contacts and Enquiry: jimmywong@myndar.com Website: www.myndar.com (This user manual / product specification is subjected to be changed without prior notice) P.
FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.