Insulin Pump System Overview The Personal Diabetes Manager (PDM) Pump Base Reservoir Patch 1 5 1. Power button 2. Home Key (Software Key) 3. Charging Port 4. Sound Hole 2 4 5. Indicator light 3 • Your ultra-thin Patch Pump is composed of a reusable Pump Base (MD0201) and a disposable Reservoir Patch (MD0200) which stores up to 200 U of insulin and lasts for up to 3 days.
PDM Settings 1. Turn on/off the PDM • Turn-on - Long-press the power button, a green light will flash. • Turn-off - Long-press the power button for about 2 seconds, then slide to power off. Or long-press the power button for about 8 seconds. 2. Wake the PDM When the screen goes black, press the power button and then slide to unlock 3. Select language and country www.medtrum.com 4. Set time and date Note: You can only change the date and time when there is no activated Reservoir Patch. 5.
6. Set audio options 8. Find Pump Base SN Main Menu ➔ Settings ➔ General ➔ Audio Options You can find the Pump Base SN on the product box or on the back of the Pump Base. If you set the audio option to Audio off /Vibrate off, your PDM only vibrates when a serious Alarm occurs. 7. Set display settings 9.
Basal Settings Main Menu ➔ Settings ➔ Insulin Pump ➔ Basal Setup 1. Max Basal Tap the Max Basal rate to edit it 2. Edit Basal Pattern 1. Tap Edit Basal, then select the Pattern to edit it 2. Set basal rate • Tap blue U/H field to set the Basal rate. • You can set a basal rate between 0 and the Max Basal Rate with an increment of 0.05 U/H. 3. Add Time Segment • Tap +Add Time Segment to add a new segment. • You can set up to 48 segments for each day. 4. Delete Time Segment www.medtrum.
Bolus Settings Main Menu ➔ Settings➔ Insulin Pump ➔ Bolus Setup 1. Max Bolus Tap the Max Bolus to edit it • Turn on/off the Bolus Calculator • Set IC ratios • Set Insulin Sensitivity • Set BG target • Set IOB Time (Active Insulin Time) www.medtrum.com 2. Set up the Bolus Calculator 3.
Start a new Patch 1 2 www.medtrum.com 3 Select the infusion site • Clean, less hair, no sweat, uncovered, enough fat (at least 5mm thick), away from navel. • A new infusion site should be at least 2.5 cm (1 inch) away from the last site. • If you choose an infusion site on your abdomen, back or buttocks, apply the Patch horizontally. • If you choose an infusion site on your upper arm or thigh, apply the Patch vertically. Prepare the infusion site • Wash your hands with soap and water.
Start a new Patch 5 Fill the New Reservoir Patch With the help of your healthcare provider, decide on the amount of insulin (70 U - 200 U) you need to insert into the Reservoir Patch. Warning: Do not inject air into the fill port. Doing so may result in unintended or interrupted insulin delivery. 1. Push air into the vial. 2. Fill the syringe with insulin. Remove air 3. Keep the syringe vertical to the Patch Pump, and the needle inside the fill port. Retract the plunger to remove air bubbles. 6 5.
Start a new Patch Priming takes about 3 minutes. 7 Place the Patch 1. Remove the safety lock www.medtrum.com 5. Press the needle button with one quick motion to completely insert the needle 8 Medtrum Simplifying Diabetes 2. Peel off the adhesive liners 8 3. Press the Pump against the skin Start Insulin Delivery 4.
Read Pump Delivery Status 1. Insulin Delivery Status 2. IOB 3. Delivery details 4. Pump RF Signal 5. Remaining insulin in Reservoir 6. Alarm/Alert Icon Shape and Color Grey ring Grey ring indicates that there is no activated Pump. Green ring Green ring represents the basal delivery. Green and dark green ring Green ring with dark green part represents Temp Basal, the dark green part indicates the progress of Temp Basal delivery.
Temp Basal Activate a Temp Basal Main Menu ➔ Basal ➔ Temp Basal With a Temp Basal you can adjust your Basal rate for a short time Select a Basal type, rate or percent and duration Cancel a Temp Basal Main Menu ➔ Basal ➔ Cancel Temp Basal www.medtrum.
Manual Bolus 1 Main Menu ➔ Bolus ➔ Manual bolus 4 Slide to deliver Normal Bolus 2 Set Bolus dose Extended Bolus 3 www.medtrum.
Food Bolus Calculator 1 Main Menu ➔ Bolus ➔ Bolus Calculator 4 Normal Bolus 2 Enter BG or Carb, or both Extended Bolus Set duration www.medtrum.
Suspend & Resume A Bolus is being delivered Suspend Main Menu ➔ Suspend Bolus All www.medtrum.
Deactivate the Patch 1 Deactivate the Patch Menu➔ Patch➔ Deactivate Patch 2 Remove the Patch • After the Reservoir Patch is deactivated, retract the needle with our release tool. • Gently remove the entire Patch Pump. Use a medical adhesive remover or baby oil if necessary. • Hold the both ends of the Pump Base and pull up the Pump Base to remove it from the old Reservoir Patch. • Discard the old Reservoir Patch according to your local waste disposal regulations. Do NOT discard your Pump Base.
Alerts & Emergency Kit Alert Emergency Kit Actions to Take END OF SUSPEND Check BG. Resume basal delivery if necessary. LOW RESERVOIR Change Patch soon. PATCH EXP IN 1 HOUR Change Patch soon. PATCH BATTERY LOW Change Reservoir Patch soon. Fast-acting glucose tablets or gel Urine ketone testing supplies Actions to Take PATCH EXPIRED Change Patch. Check blood glucose. EMPTY RESERVOIR Change Patch. Check blood glucose. EXCEEDS MAX TDD Change Patch. Check blood glucose. Check history.
Your Personal Settings Max Basal Rate: ________________ U/H Basal Pattern Name: ___________________ Start Time Rate (U/H) Rate (U/H) Start Time Rate (U/H) Start Time : : : : : : : : : : : : : : : : : : : : : : : : : : : : Name www.medtrum.
Your Personal Settings I:C Ratio I:C (g Carb) Start Time ISF (mmol/L) : 1U : g : 1U : mmol/L : 1U : g : 1U : mmol/L : 1U : g : 1U : mmol/L : 1U : g : 1U : mmol/L : 1U : g : 1U : mmol/L : 1U : g : 1U : mmol/L : 1U : g : 1U : mmol/L Max Bolus: __________________________U BG Target (mmol/L) Start Time : Low Limit High Limit Active Insulin Time: _______ : _______ : : : : www.medtrum.
Caution Labelling requirements This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Information to user Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. www.medtrum.
Caution RF warning for Portable device The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. www.medtrum.
Medtrum Technologies Inc. 7F, Building 8, No. 200, Niudun Road Shanghai 201203, China Tel: +86-21-50274781 Fax: +86-21-50274779 www.medtrum.com EC REP 0197 Medtrum B.V. Nijverheidsweg 17 5683 CJ Best The Netherlands Tel: +31(0) 499745037 This product complies with Directive 93/42/EEC (MDD) and Directive 2014/53/EU (RED). SY-201 IM881160WW 348644 Version:1.