Datasheet

MAX. No. of PSUs on 16A
CIRCUIT BREAKER
9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL APC-25-350
APC-25-700
DC VOLTAGE RANGE
RATED CURRENT
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER VOLTAGE
25~70V
11~36V
350mA
700mA
24.5W
25.2W
300mVp-p
300mVp-p
±5.0%
±1.0%
±3.0%
1500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load
47 ~ 63Hz
83%
83%
0.4A/230VAC;0.8A/115VAC
0.25mA / 240VAC
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.2%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristic for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
8. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
25W Single Output Switching Power Supply
Constant current mode power supply
Universal AC input / Full range
Withstand 300VAC Surge input for 5 seconds
Protections:Short circuit / Over voltage
Fully isolated plastic case
Small and compact size
Cooling by free air convection
IP42 design
100% full load burn-in test
Suitable for LED related fixture or appliance
(such as LED Decoration or Advertisement devices)
Low cost / High reliability
2 years warranty
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
File Name: APC-25-SPEC 2018-09-29
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
HOLD UP TIME (Typ.) 20ms/230VAC 12ms/115VAC at full load
76 ~ 94V
41 ~ 49V
84*57*29.5(L*W*H)
COLD START 45A(twidth=310 s measured at 50% Ipeak) at 230VACμ
UL8750 (except for APC-25-350), CSA-C22.2 No. 250.0-13 (only for APC-25-700&1050), BIS IS15885, EAC TP TC 004,
IP42 approved; design refer to EN60950-1
518.9K hrs min. MIL-HDBK-217F (25 )
Features :
LPS (except for APC-25-350)
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
90 ~ 264VAC 127 ~ 370VDC
APC-25 series
CURRENT ACCURACY
±8.0%
EMC IMMUNITY
Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020
EMC EMISSION
APC-25-500
15~50V
500mA
25.2W
300mVp-p
83%
55 ~ 68V
APC-25-1050
9~24V
1050mA
25.2W
300mVp-p
83%
27 ~ 35V
-30 ~ 70 (Refer to "Derating Curve")
0.13Kg; 72pcs/10.4Kg/0.92CUFT
Protection type : Shut down o/p voltage, re-power on to recover
(only for APC-25-700&1050)
( only for APC-25-500)
IP42
IS 15885(Part 2/Sec13)
R-41027766
THOMAS SAMUEL
THOMAS SAMUEL