COSEC ARGO Contents Know your COSEC ARGO 3 What your Package Contains 7 Preparation for Installation 7 Installation Instruction - Wall Mounting 9 Installation Instruction - Flush Mounting 15 Connecting the Cables 21 Configuring the Settings from ARGO 24 Configuring the Settings from ARGO Web Page 29 Technical Specification 33 Please read this guide first for correct installation and retain it for future reference.
Know your COSEC ARGO Figure 3: Rear View The COSEC ARGO is available in three different variants as follows: 1) COSEC ARGO FACEE 2) COSEC ARGO FACEM 3) COSEC ARGO FACEI Figure 1: Front View Touch Screen Display RGB Camera IR Camera Figure 2: Bottom View IR LED Mounting Screw Hole Back Plate or Wall Mounting Plate Flush Mounting Plate Knock Out Area 3 4
Pre-Installation Safety Instruction Figure 6 1. Do not install the device in extremely hot temperature or under direct Sunlight on turnstile or at extra bright places. This may affect the LCD and Camera sensor of device. You can do indoor installation or on the turnstile under the roof as shown in Figure 4. 120cm - 130cm Figure 4 30cm 120cm 2.
Built In Cameras • • For providing efficient Face Recognition, two Cameras are used in COSEC ARGO. • These Cameras are 2MP with Focal length of 2.8mm. The Cameras detect liveness and capture user images. The captured image is used to identify user for Time and Attendance Management.
Installation Instruction: Wall Mounting Step 1: Place the Wall Mounting plate and trace screw holes 1 and 2 on the wall where the device is to be installed. Step 2: Drill the screw holes along the traced markings. Fix Wall Mounting plate with the supplied screws. Tighten the screws with a screw driver.
Step 3: Connect the cables of the COSEC ARGO unit and lead all the cables through the duct of the Wall Mounting plate into the electrical box recessed in the wall i.e. concealed wiring or through the bottom of the device in non-concealed wiring. • • Keep all the cables parallel to the side of the COSEC ARGO body in such a way that it should not cover the back portion of the unit as illustrated in figure below.
Step 4: Align COSEC ARGO on the mounting plate and hook it into the mounting slot. Press the bottom side inwards to lock it in place. Step 5: Insert the mounting screw into the mounting screw hole at the bottom of the device. Tighten the screw to complete the Wall Mounting.
Installation Instruction: Flush Mounting Step 1: Place the Flush Mounting Template on the desired installation surface. • • Mark the area along the dotted line and trace the four screw holes (say A,B,C,D) on the wall as shown in Figure 7. Now drill the dotted line area and four screw holes (say A,B,C,D) on the wall as illustrated in Figure 8.
Step 3: Connect the cables of the COSEC ARGO unit and lead all the cables through the Flush Mounting plate into the electrical box recessed in the wall. • • Figure 10 Keep all the cables parallel to the side of the COSEC ARGO FACE body in such a way that it should not cover the back portion of the unit as illustrated in the figure below. Radially curve all the cables and lead it through the duct to fit the flush mounting plate easily with COSEC ARGO.
Step 4: Align COSEC ARGO with the Flush Mounting plate and hook it into the mounting slot. Press the bottom side inwards to lock it in place. Figure 12 Step 5: Insert the mounting screw into the mounting screw hole at the bottom of the device. Tighten the screw to complete the Flush Mounting.
Connecting the Cables • Figure 15 For Concealed wiring; first draw out sufficient length of the cables from the hole you have made on the mounting surface. • Connect the Power, External Reader and EM Lock cable assemblies to the 20 PIN connector affixed on the back side of the COSEC ARGO Unit. • Connect the Ethernet Cable to the LAN port. • Connect the micro USB port to the Printer or Broadband dongle. If required, use a micro USB cable extender.
Diode Connection for Back EMF Protection Relay Pin 1 Power + - Configuring the Settings from ARGOFACE Assigning IP/ Server Address to Device (For first time user only) Relay Pin 2 Cathode Anode EM Lock Reverse biased Diode GND • Connect the Overswing diode in reverse biased condition parallel to the EM Lock for better lifetime contact and to protect the device from inductive kickback.
Setting the Device and Server Address from Menu Figure 21: Tap Menu Figure 23: Tap Admin Figure 24: Tap Settings Figure 26: Set the LAN Configurations Figure 25: Tap LAN Figure 22: Enter Password If you are logging in for the first time, you need to set the Password in Choose New Password and confirm the same in Confirm New Password.
Checking the Connectivity Status Device is Connected Figure 27: Tap Server Device is Disconnected Figure 28: Set the Server Configurations (COSEC CENTRA) In case of COSEC VYOM Figure 31: Tap About Device Figure 29: Select Server as VYOM 27 Figure 32: Tap Connectivity Figure 30: Set the Server Configurations (COSEC VYOM) Figure 33: Connectivity Status 28
If you enable the Auto Add New Devices check box in the Server (Admin Module > System Configuration > Global Policy > Device) the device will be added automatically. You can also add the device later manually.The Status will be online only if the Device is added in the Server. • Click Basic Profile and select the desired Server Connection – COSEC CENTRA or COSEC VYOM, see Figure 35. Figure 35 Make sure the Monitor Service is running.
Figure 36 Figure 37 80 For COSEC VYOM • • 31 Enter the Tenant ID, for example see Figure 37. Click the Submit button, the Web Server URL (Address) and Directory Name will be fetched automatically from the Server which cannot be modified, see Figure 37.
Technical Specification Technical Specification 33 Event Buffer 5,00,000 Built In WiFi Yes (IEEE 802.11 b/g/n) Input Power 12V DC @2A and PoE Yes Credential Support Face, PIN, Card, BLE Built In Bluetooth Built In USB Yes Reader Power Output Max 12V DC @0.250A Operating Temperature 0 °C to +50 °C Reader Interface RS 232 and Wiegand Type Dimensions (H x W x D) 186mm x 74mm x 50mm (Wall Mount) 186mm x 74mm x 16mm (Flush Mount) Door Lock Relay Max 30V DC @2A Weight 0.
FCC Compliance Disposal Of Product After End-Of-Life This device complies with part15 of the FCC rules. Operation is subject to the following two conditions: WEEE Directive 2002/96/EC 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits of Class A digital device, pursuant to part 15 of the FCC Rules.
Warning Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC RF Radiation Exposure Statement: 1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. 3.