WIRELESS MICROPHONE SYSTEM TA LK
Contents: Introduction -------------------------------------------------------------------------- 1 Quick Start Guide ------------------------------------------------------------------ 2 Product Description ---------------------------------------------------------------- 4 System Operation ------------------------------------------------------------------ 8 Color Label Identification --------------------------------------------------------- 15 Basic Connections ----------------------------------------------
Introduction Thank you for purchasing our product. This PLL synthesized wireless microphone system operates in UHF band frequency with 700 selectable channels. Please read this instruction manual carefully before operating the system. This manual covers the function and operation of the wireless microphone system. FCC Statement This device complies with part 15 of the FCC rules.
Quick Start Guide 1. Connected Receiver Power Cable 2. Connect Mixer or Amplifier AUDIO OUT AUDIO OUT UNBALANCED UNBALANCED LINE D SQ 12V LINE MIC BALANCED BALANCED 3.
4. Insert Batteries 2 2 5.
Receiver Front : RS-61: Diversity Receiver 5 1 4 2 3 6 RS-66: Diversity Dual Channel Receiver 5 1 4 5 2 3 6 4 2 1. Power Button. 2. VA LCD Display: Display group, channel, frequency and settings. 3 Tap the channel forward / backward. 4. SYNC Button: Press the button to actuate the synchronization with transmitter. 5. SET Button: Press button to activate the scan or preset mode or manual mode. 6. Volume Controller: Adjust the receiver output level.
VA LCD Display : 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. PRESET : Use this mode to set multiple constructions by preset group. Manual : Use this mode to select free channel by manually. SCAN : Use this mode to set free channel by scan function. SYNC : The synchronization process is actuated. GR : Display selected preset group. CH : In “PRESET” mode, display selected preset channel. CH : In “SCAN” mode, or “MANUAL” mode display selected channel number. FREQ : Display selected frequency.
Handheld Microphone 1 TALK TALK UF-61 UF-61m UF-62 1. Grille: Protects the microphone capsule and helps reduce breath sounds and wind noise. 2. SYNC Button: Press to actuate the synchronization process with the receiver. 3. Talk Button: Push the button up to talk. Push the button down for mute. 4. Battery compartment: Insert two AA size batteries into the compartment and make sure that the polarity of batteries is correct. 5.
UT-61 Bodypack Transmitter 4 2 8 6 3 1 5 1. 2. 3. 4. 5. 6. 7. 8. 9. 9 7 Power Button: Press for 2 seconds to power the microphone on or off. Mute Button: With the transmitter on, a slight press for button will toggle between mute and unmute function. Power LED: Indicate the power / low battery level status. LED Indicator Status Green Ready Flashing Green The synchronization process is actuated.
Connecting the receiver Prior to setting up, please check that the transmitter and receiver are tuned to the same frequency or channel. Two or more transmitters operating in the same frequency can not be used at the same time and area. Connected the provided DC power supply to the receiver power input with an appropriate AC power source. The LCD display will light and the receiver is on. AUDIO OUT UNBALANCED Using a standard audio cable with 3-pin XLR connectors or 6.
Setting up channel on receiver Press the “SET” button for 2 seconds, “PRESET” or “MANUAL” or “SCAN” mode will flash. Press the or button to select the “MANUAL” mode. Press “SET” button to lock the “MANUAL” mode. Press or button to change the channel forward or backward. Press the “SET” button to lock the setting. NOTE: If user needs to set up multi-receiver system, please keep your previous receiver-microphone pair power on. Then go no to next scanning procedure.
Scan Mode Set interference-free channel by frequency scan function. Press the “SET” button for 2 seconds, “PRESET” or “MANUAL” or “SCAN” mode will flash. Press or button to select the “SCAN” mode. Press the “SET” button, “SCAN” will stop flashing,it will searching the free channel automatically. Press the “SET” button, GR and CH digits will stop flashing, and “SCAN” is done. If the system fails to select free-interference channels, it will automatically scan available channels from all frequency ranges.
Preset Mode Set multiple constructions by using preset channels. Excluding the interference from external, up to 12 system can be operated simultaneously in each group (Region dependent). Press “SET” button for 2 seconds, “PRESET” or “MANUAL” or “SCAN” mode will flash. Press or button to select the “PRESET” mode. Press the “SET” button, “PRESET” will stop flashing. GR digit will flash simultaneously. Press or button to select GR number.
Set up the handheld microphone / bodypack transmitter Open the battery cover and insert batteries into the battery compartment conforming to the polarity (+)(-) marks. Unscrew the handheld Mic and open the battery cover to insert the battery into the battery compartment and confirm the marks of the polarity (+) (-). Connect to the lavalier microphone, headset microphone or guitar cable.
2 2 Press for 2 seconds to turn the Handheld/ Bodypack transmitter on. If the LED stays flashing , it indicates that the battery will out of power soon and should be changed. Bodypack Handheld Adjust the audio input level. • 0dB • -10dB (Default Setting) • -20dB • 0dB • -10dB • -20dB NOTE: When you don’t use this device for a long term period, please switch the power switch to “off” mode to save more electric power.
Synchronizing a transmitter with a receiver Automatic frequency synchronization via remote channel for easy setup. First, switch the transmitter and the receiver on. Press and hold the SYNC button on your transmitter. The SYNC flashes on the receiver display panel. At the same time, press the SYNC button of the receiver to transfer the selected frequency to the transmitter. When using SYNC setting, the distance of receiver and transmitter is within 1 M.
Color Label Identification TA LK You can also stick the color label on the receiver and transmitter for quickly identify the pair system.
Basic Connections To install a receiver in a 19” standard rack by using 2 short L type metal racks. L4 L4 C1 To mount a receiver in a 19” standard rack by using 2 long L type metal racks. (L type long metal racks is an optional product, so please purchase extra in local shops.) L3 By using the antenna holder to install the UHF antenna in high place for better reception quality.
Trouble Shooting whether is set too high or too low.