GB www.lehmann-locks.com Locker lock M610 with keypad (M610 TA03) Operating Instructions BDA M610 TA03 / 2021-08-17 (GB) Content Page General system description / Operating description........................................................ 2 Safety precautions / Care & maintenance / Technical specifications............................... 3 System components & package contents......................................................................... 4 Dimensions........................................
GENERAL SYSTEM DESCRIPTION The M610 TA03 (keypad) locking system is a locker lock with a motor-driven locking bolt intended for use in the home and office. This manual gives you information in order to install and operate the locking system correctly. Keep the operating instructions in an easily accessible place. Using the locking system in applications for which it is not intended may result in irreparable damage to it and render any claims null and void.
! SAFETY PRECAUTIONS U Pack the batteries to transport the lock in such a way, that no short circuit can occur (explosion and fire hazard). U On changing the batteries, ensure correct battery polarity and position. U Dispose of spent batteries and packaging material in the proper manner (see page 20, „Disposal“). U Do not heat batteries, take them apart or short-circuit them. U Never throw batteries into open fires. U The batteries must not be charged.
SYSTEM COMPONENTS / PACKAGE CONTENTS Please note that these operating instructions apply to different product variants. The packaging content therefore depends on the respective product variant. The product variants and installation recommendations shown here are intended for furniture with a wood thickness of 19 mm. For different wood thicknesses and materials, the screws for fixing the lock and the keypad must be adjusted. 9 6 8 5 7 3 1 2 4 1. 2. 3. 4. 5. 6.
DIMENSIONS Locker lock M610 105 105 25 9 4,5 94 14 14 5 105 94 94 25 27,5 94 ,4 (M610 for left hand doors) 4 6 (M610 for right hand doors) 8 14 44 4 6 Striker plate 4516 22 14 4 6 14 39 4 22 14 1 44 8 10 27 6 15,5 4,5 10 27 1 39 15,5 4,5 Keypad TA03 without labeling clip 53 12 32 ø3 For Für Ø19Stanzbild x 16 15,9 5 All figures in mm.
Keypad TA03 with optional labeling clip 53 32 12 ø3 88 64 19 ø 18 ,8 28 16 GETTING STARTED / CHANGING BATTERIES Make sure that the lock and keypad are correctly connected to each other by the connection cable. Pay attention to the correct connection of the plugs and sockets. Open the battery compartment cover by inserting the pin into the small holes and releasing the cover. Lift the cover off at the same time. Insert the batteries CR123A in the battery compartment.
EMERGENCY POWER SUPPLY The locking system has the option of an emergency power supply in case of empty batteries. 1 2 3 Insert the pin into the hole on the bottom side and press until the cover is released. Then lift up the cover. Hold a 9V battery to the contacts at the keypad while entering the code or emergency opening code for opening the lock. Pay attention to the correct polarity of battery! 4 Insert the two guide lugs of the cover into the recesses. Press the cover until it clicks into place.
INSTALLING THE LOCKING SYSTEM Mounting position of lock M610 Mounting position of keypad TA03 Door 70 23 Door 94 54 32 1 9 ho le in th e do or 21 64 32 94 Sidewall Sidewall 47 Exemplary for a right door. Mounting position of striker plate 4516 X Door Sidewall Sidewall X + 36,5* Door Inlay doors * Overlay doors ** X = Door thickness 8 All figures in mm.
In order to attach the cover to the already mounted keypad unit TA03, insert the two guide lugs of the cover into the recesses and press the cover until it clicks into place. Installation instructions: • Do not use countersunk head screws when installing the locker lock, the keypad and the striker plate. • Flat headed screws (3,0 x 15 mm) are recommended for mounting the striker plate (only included in single-set packaging).
STRUCTURE OF THE KEYPAD TA03 LED display Numbers 0-9 Cancel Enter Trip point for removing the cover for emergency power supply You can cancel any operation at any time by pressing the cancel button there is one short red flashing. Any input already made is deleted. x . When the cancel button is pressed, During operation, make sure that each key input is acknowledged by a light signal at the LED display! If a light signal does not appear, the key input was not accepted.
FACTORY SETTINGS The following settings apply for the locking system as delivered from the factory: U Free Code mode U The lock is in open position U Master code: 9-0-8-0-7-0-5-5-5-5 U Emergency opening code: 1-0-1-0-5 U Automatic locking is deactivated U Automatic opening is deactivated ATTENTION: I t is highly recommended to change the factory set master code and factory set emergency opening code! OPENING & CLOSING IN FREE CODE MODE The lock must be in open position.
SWITCHING TO FIXED CODE MODE The lock must be in open position. There must be no battery warning. The fixed code must be 3 to 10 digits. If you have already changed the default master code, enter your valid master code here. In order to confirm the master code, press the keys x + simultaneously. Enter of master code (example: factory settings) Keys 9 0 8 0 7 0 5 5 5 5 simultaneously Display Keys x + The lock is in configuration mode (continuous green light).
USER CHANGES THE FIXED CODE The lock must be in open position. There must be no battery warning. The fixed code must be 3 to 10 digits. If you have already changed the default fixed code for the user, enter your valid code here. The previous code will be overwritten by entering the new code. Enter of valid fixed code (example: 1-4-5-6) Keys 1 4 5 6 The lock waits for entering a new fixed code (continuous green light). x + simultaneously Display After the buttons code is entered.
SWITCHING TO FREE CODE MODE The lock must be in open position. There must be no battery warning. If you have already changed the default master code, enter your valid master code here. In order to confirm the master code, press the keys x + simultaneously. Enter of master code (example: factory settings) Keys 9 0 8 0 7 0 5 5 5 5 simultaneously Display Keys x + The lock is in configuration mode (continuous green light). When the LED display turns off, Free Code mode is activated.
CHANGING THE MASTER CODE It is highly recommended that you change the default master code and to choose the longest possible and secure master code. The lock must be in open position. There must be no battery warning. The master code must be 3 to 10 digits. If you have already changed the default master code, enter your valid master code here. In order to confirm the master code, press the keys x + simultaneously.
CHANGING THE EMERGENCY OPENING CODE It is highly recommended that you change the default emergency opening code and to choose the longest possible and secure emergency opening code. The lock must be in open position. There must be no battery warning. The emergency opening code must be 3 to 10 digits If you have already changed the default master code, enter your valid master code here. In order to confirm the master code, press the keys x + simultaneously.
EMERGENCY OPENING If you have already changed the default emergency opening code, enter your valid emergency opening code here. Enter emergency opening code (example: Werkseinstellung) Keys 1 0 1 0 5 Lock opens. Display After an emergency opening in the Fixed Code mode, the lock can be used again normally with the previously programmed fixed code. If you want to change the fixed code, follow the instructions in section „User changes the Fixed code“ or in section “Switching to Fixed Code mode”.
AUTOMATIC LOCKING IN FIXED CODE MODE The lock must be in open position. There must be no battery warning. This feature can only be activated in Fixed Code mode. If you have already changed the default master code, enter your valid master code here. In order to confirm the master code, press the keys x + simultaneously. Enter of master code (example: factory settings) Keys 9 0 8 0 7 0 5 5 5 5 simultaneously Display Keys x + The lock is in configuration mode (continuous green light).
AUTOMATIC OPENING IN FREE CODE MODE The lock must be in open position. There must be no battery warning. This feature can only be activated in Free Code mode. If you have already changed the default master code, enter your valid master code here. In order to confirm the master code, press the keys x + simultaneously. Enter of master code (example: factory settings) Keys 9 0 8 0 7 0 5 5 5 5 simultaneously Display Keys x + The lock is in configuration mode (continuous green light).
BATTERY WARNING The locking system is equipped with two battery warning levels (see table below).: Warning level LED-Display Meaning Stage 1 The batteries are weak and should be changed. Opening and closing of the lock are possible. Configuration changes are not possible. Stage 2 The batteries are exhausted and must be changed immediately! The lock can only be opened. Configuration changes are not possible. For changing the batteries see page 6 „Getting started & changing batteries“.