GB www.lehmann-locks.com Captura (Captura 100 MIFARE®) Operating instructions BDA Captura 100 MIFARE® / 2020-10-26 (GB) Content Page General Description / Technical Specifications / Safety Precautions ........................................2 Care and Maintenance / Factory Settings / Functional Description..........................................3 Overview of Transponder Cards ...............................................................................................
GENERAL DESCRIPTION The Captura 100 MIFARE® lock is a battery-operated electronic furniture lock based on RFID technology, which is intended for use in living and office areas inside buildings. These operating instructions provide you with information on how to operate the locking system without errors. Keep the operating instructions in an easily accessible place. Improper use can destroy the locking system and lead to the loss of any warranty claims.
UU The battery must not be charged! UU Keep the product away from children, as small parts may be swallowed! UU Any persons swallowing batteries must seek immediate medical advice! UU Damaged and/or leaking batteries may cause acid burns and/or poisoning! CARE AND MAINTENANCE UU Do not spill any liquid over or into the individual components of the lock, and never immerse the components in any liquid. UU The product should not be exposed to direct sunlight.
OVERVIEW OF TRANSPONDER CARDS Card type Description Installation card (only for assembly and testing purposes) The installation card can be used specially for assembly and testing purposes in order to perform basic functions on the lock (opening and closing). Furthermore, the lock can be closed using the installation card for transporting the furniture to its destination. This card is for universal use. Any number of installation cards can be used at any lock.
SYSTEM COMPONENTS AND PACKAGE CONTENTS Please note that these operating instructions apply to different product versions. The package content therefore depends on the respective product variant. The product variants and mounting recommendations shown here are intended for wooden furniture with a thickness of 16-19 mm. In the case of deviating thicknesses and materials, the screws for mounting the lock must be adapted. Sid ew all or Do 5 7 9 1 6 3 8 4 2 Components: 1. Lock Captura 2.
13,5 25 7,5A Locking pin unit SD Type 38 20 3, 7 7 3, 7,5 17,5 38 13,5 25 20 20 3, 7 7 3, Locking pin unit SD Type A with ejector pin A1 7,5 7 3, 7 3, 30 24,5 65 40 34,5 20 12,5 8 52 13,5 25 30 24,5 40 34,5 17,5 7 21 19 17,8 27,8 40 7,5 ,8 3 16 38 26 8 17,5 Locking pin unit SD Type B 48 54 54 54 54 54 6,5 6,5 6,5 70 70 48 3,3 3,3 3,3 54 70 (8,8()8,8) (8,8) 6 All dimensions in mm.
A lightpoint pin can optionally be installed to display optical signals on the furniture front. 5 58 6,5 (53)* 1,9 6,5 Lightpoint O10.1 for HPL with material thickness of 10-15 mm 1,9 5 Lightpoint O16.1 for wood with material thickness of 16-21 mm 15,5 9,5 48 20 processes and functional checks with the cabinet door open. In the event of a malfunction, you always have access to all components. 27 54 IMPORTANT: Install the lock only when it is unlocked. Hand-tighten all screws.
Note that the lightpoint can be installed as an option. Without a lightpoint, only acoustic signaling is available. Mounting the lightpoint: 5 27 27 To be installed without tools. Mounting the lock with locking pin SD Type B, e.g. drawer: 54 Top Shelf inside view 54 C 8 All dimensions in mm.
ATTENTION: I f no lightpoint is installed, a sticker is recommended on the outside of the door, centered behind the lock, for correct positioning of the RFID transponder. Using the LEHMANN RFID sticker: 1) Remove the backing paper. 2) Stick the self-adhesive transfer film with the RFID symbol on the outside of the door, centered behind the lock. 3) Carefully pull off the transfer film so that only the RFID symbol sticks to the door.
GETTING STARTED AND CHANGING BATTERIES 1. Opening the cover of the battery compartment by loosening the screw. 2. Insert the battery. Pay attention to the correct polarity of the battery. A long acoustic and an optical signal are provided. 3. Then close the battery compartment cover and hand-tighten the screw. CAUTION: U se only a CR123A primary-battery. Insert the battery after installing the lock in the furniture. Inserting the battery Battery is inserted correctly in the battery compartment.
USING THE INSTALLATION CARD (optional) During installation, one or more installation cards can be used. The installation cards are ready for immediate use and do not have to be programmed. With the installation cards, the basic functions (opening and closing) can be carried out on the lock. It is not possible to program user cards with the installation card. The installation card can no longer be used on a lock as soon as the master card has been programmed.
Programming the User Cards (only for “assigned use” mode) In “assigned use“ mode, a maximum of 250 different user cards can be programmed per lock. It is not possible to program user cards in “shared use“ mode. In “shared use“ mode, the lock can be opened and closed without first programming the user cards (see Closing and Opening, see below). Programming user cards Hold the master card in front of the lock. Hold the user card in front of the lock. The card is accepted and programmed.
UNAUTHORISED TRANSPONDERS CARDS Rejection of an unauthorised user card Unauthorised user card is held in front of the lock. The card is rejected. FACILITY MANAGER FUNCTION In the event that an authorised person only briefly wants to check whether for example a cabinet is actually occupied, the lock can be opened with the master card. With this function, the lock opens for 30 seconds and then closes automatically.
DELETING INDIVIDUAL TRANSPONDER CARDS (only for “assigned use” mode) Insofar as further user cards were programmed on the lock, these can continue to be used on this lock after an individual user card has been deleted. For the deleting process, the lock must be open. To do this, first carry out an emergency opening with the master card if necessary (see Emergency opening, P. 13). Deleting individual user cards Hold the master card in front of the lock.
Hold the master card in front of the lock. CHANGING THE OPERATING MODE The lock has two modes: “assigned use“ and “shared use“. When the lock is open, you have the option of changing the mode. To do this, the master card and the programming card “P1: Mode“ are required. The programming card set must be bought separately from LEHMANN Vertriebsgesellschaft mbH & Co. KG. The cards are for universal use. Changing the operating mode Hold the master card in front of the lock.
DEACTIVATING AND ACTIVATING ACOUSTIC SIGNALS Acoustic signalling is activated when the system is delivered. You have the option of deactivating the acoustic signals with the aid of the master card and the programming card “P2: Sound“. For this, the lock must be open. It is recommended that the acoustic signals should only be deactivated if the RFID reader with the LED is mounted outside the item of furniture.
Resetting to factory settings Hold the master card in front of the lock. Hold the programming card “P3: Reset“ in front of the lock. Hold the programming card “P3: Reset“ in front of the lock again. Hold the master card in front of the lock. after about 10 seconds ACTIVATION AND DEACTIVATION OF AUTOMATIC LOCKING With the programming card “P4: Auto Locking”, the function “automatic locking“ can be activated and deactivated in the operating mode “assigned use“.
Hold the programming card “P4: Auto Locking“ in front of the lock again. Automatic locking is activated. Automatic locking is activated. Hold the programming card “P4: Auto Locking“ in front of the lock again. Automatic locking is deactivated. Automatic locking is deactivated. Hold the master card in front of the lock.
REORDERING MASTER CARDS With this locking system, you have the option of ordering replacements for your master cards at your own expense. For this you obtained a service key together with the master cards. Please keep the service key carefully and securely. The service key makes it possible to reorder the master card specified there. To reorder these cards, please contact LEHMANN Vertriebsgesellschaft mbH & Co. KG at the following email address: sales@lehmann-locks.
Regulatory Information for USA and Canada: FCC ID: W2YL3NF13CX This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment.