MANLEY LABORATORIES, INC. OWNER'SMANUAL MANLEY LAB SERIES MONOBLOCK 100 WATT AMPLIFIER MANLEY LABORATORIES, INC. 13880 MAGNOLIA AVE. CHINO, CA.
CONTENTS SECTION PAGE INTRODUCTION 3 MAINS CONNECTIONS 4 CONNECTING YOUR AMPLIFIER 5 DIAGRAM TOP VIEW 6 DIAGRAM REAR VIEW & FRONT VIEW 7 BIAS PROCEDURES 8 OPERATIONAL NOTES 9 SPECIFICATIONS 10 WARRANTY 11 WARRANTY REGISTRATION 12
INTRODUCTION THANK YOU!... for choosing the Manley LAB SERIES Monoblock 100 watt Amplifiers. Designed by David Manley, the Manley Monoblock 100 watt Amplifiers use only the best available components, with the shortest and cleanest signal path possible. The circuit and the components used have been chosen carefully after years of development and refinement for reliability, constancy and most importanly, musical, accurate, and emotional delivery of the sound.
MAINS CONNECTIONS Export units for certain markets have a moulded mains plug fitted to comply with local requirements. If your unit does not have a plug fitted the coloured wires should be connected to the appropriate plug terminals in accordance with the following code.
CONNECTING YOUR AMPLIFIER Setting up your amplifiers is rather easy. 1. Connect all source components (turntable, CD, Tuner, Tape DAT, etc.) to your preamplifier. 2. Connect the RCA interconnects from the output of the preamplifier or switching center to the RCA input on the back of the amplifiers. 3. Connect the hot or "+" speaker cable to the red binding post and the common or "-" speaker cable to the black binding post. Ensure that the other end of the cable is connected correctly to the speaker.
TOP VIEW AC BALANCE ADJUST BIAS ADJUSTMENT POINTS 1 2 3 4 3 1 MASTER BIAS ADJUST 2 4 6414 12AT7 AC BALANCE MEASUREMENT POINTS 1 2 3 4 BIAS MEASUREMENT POINTS Amplifier Overhead View Tube Location & Bias adjust points OUTPUT TUBES:4 x RUSSIAN EL34/6CA7 The EL34's used are the Russian up-rated EL34's. This has been proven to be the rugged and reliable of this type. The MANLEY 100 WATT MONOBLOCK has been thoroughly optimised around this tube.
REAR VIEW RCA INPUT B+ FUSE MAINS IN SLO-BLO IEC MAINS FUSE SLO-BLO SPEAKER OUTPUT BINDING POSTS FRONT VIEW MANLEY TRIODE LABORATORIES, INC DESIGNED BY DAVID MANLEY TETRODE LAB SERIES MONOBLOCK 100
BIAS PROCEDURES The Manley Monoblock 100 watt Amplifiers use a fixed bias system that requires very little attention. We recommend checking the bias every 2-3 months or any time you replace an output tube. To adjust or check the bias, follow the following steps. For this procedure you will need a voltmeter (a hand held autoranging DMM digital multimeter is the easiest) and a small flat screwdriver. 1.
OPERATIONAL NOTES TRIODE / TETRODE OPERATION: With the TRIODE / TETRODE switch, the amplifier may be set for TRIODE or TETRODE operation. When the switch is in the lower position, the amplifier is in TETRODE mode which will produce well over 100 watts.
SPECIFICATIONS Vacuum Tubes: Output Power 4 x EL34/6CA7 (Output), 1x 6414 (Driver), 1 x 12AT7 (Input) TETRODE: 135Watts (@1.5% THD 5 ohm load) TRIODE: 65 Watts (@1.5% THD 5 ohm load) Frequency Response, +/- .5 dB 10 Hz - 30 KHz Input Sensitivity 800 mV Input Impedance 100 KOhm Load Impedance 5 Ohm (fixed) S/N Ratio @440W -80 dB Power Consumption 145 Watts 348 Watts Mains Fuse 100, 110, 120V 220, 240 V B+ Fuse 4/10A (250V)SLO-BLO Dimensions W=14.
WARRANTY All Manley Laboratories equipment is covered by a limited warranty against defects in materials and workmanship for a period of 90 days from date of purchase to the original purchaser only. A further optional limited 5 year warranty is available to the original purchaser upon proper registration of ownership within 30 days of date of first purchase.
WARRANTY REGISTRATION We ask that you please fill out this registration form and send the bottom half to: MANLEY LABORATORIES REGISTRATION DEPARTMENT 13880 MAGNOLIA AVE. CHINO CA, 91710 Registration entitles you to product support, full warranty benefits, and notice of product enhancements and upgrades. You MUST complete and return the following to validate your warranty and registration. Thank you again for choosing to use Manley Laboratories. MODEL ____________________ SERIAL No.