INSTR4166 0212
Table of Contents Section 1 - General Information Safety Notices........................................................................2 Model Numbers ....................................................................3 Warranty Coverage ................................................................3 Section 2 - Installation Instructions General ..................................................................................4 Dimensions/Exploded Views ..............................................
Safety Notices When using or servicing this product, be sure to pay close attention to the safety notices in this manual. Disregarding the notices may lead to serious injury and/or damage to the water filter and/or ice machine. Throughout this manual, you will see the following types of safety notices: Text in a Warning box alerts you to a potential personal injury situation. Be sure to read the Warning statement, and then proceed carefully.
Section 1 General Information Model Numbers Parts/Labor This manual covers the following models: Model # Range Claims Replacement Cartridge AR-10000 14,000 gal capacity For ice machines up to 0 - 600 lbs Chlorine taste and odor reduction, scale inhibition K00338 AR-20000 20,000 gal capacity For ice machines 601 - 1,000 lbs Chlorine taste and odor reduction, scale inhibition K00339 (1) AR-40000 40,000 gal capacity For ice machines 1,001 - 2,500 lbs Chlorine taste and odor reduction, scale inh
Section 2 Installation Instructions General Safety These instructions are provided to assist the qualified installer. Check your local Yellow Pages for the name of the nearest Manitowoc distributor, or call Manitowoc Ice for information. Always follow these safety precautions when installing and operating the water filter system: The ArcticPure® water filtration systems are designed to reduce coarse and fine particulate matter from the incoming potable water supply.
Section 2 Dimensions & Exploded Views 3 1/4" VENT TUBE OUTLET 3/8" OD TUBE 2 17/32" INLET 3/8" OD TUBE 17 3/32" NOM. 14 5/16" 13 7/32" AR-10000 3 1/4" OUTLET 3/8" OD TUBE VENT TUBE 2 17/32" INLET 3/8" OD TUBE 21 11/32" NOM.
Section 2 Dimensions & Exploded Views (continued) INLET 3/8" OD TUBE 13 13/32" OUTLET 3/8" OD TUBE 21 5/16" NOM 17 1/2" NOM 19 9/16" NOM AR-40000 6
Section 2 Location 4. Remove the protective cap from the cartridge. ArcticPure® water filtration systems should be located on the incoming cold water line and preferably away from heavy traffic areas. The system should be mounted on a wall or structure that will support the weight of the system when filled with water. 5. Inspect the cartridge and o-rings for damage. See Replacement Parts list if replacement is required. 6. Lubricate o-rings with food grade lubricant. 7.
Section 2 Installation - AR-10000/AR-20000 & AR-40000 Shut off the incoming water supply. For John Guest Fitting Installation: NOTE: Please review the following recommendations before installing the water lines. • Tubing must be 3/8" O.D., (.371 - .376). • Cut the tube square. The outside diameter must be free of score marks. • Burrs and sharp edges must be removed prior to installation. NOTE: Use a tube insert for thin-walled plastic tubing. To install water lines into the inlet/outlet ports: 1.
Installation - AR-Pre 5. Pull on the tubing to be sure it is secure. If the tubing releases, refer to the Troubleshooting section of this manual (page 11) to reinstall. NOTE: If the AR-Pre is being retrofitted to an existing ArcticPure® system, shut off the incoming water supply, relieve the filter pressure by removing the existing filter cartridge(s), and disengage the water inlet line. A small quantity of water will be vented directly behind the cartridge body. 6.
Installation Checklist It is recommended that ArcticPure® filter cartridges be changed out: • Have the min.-max. water temperature and pressure been checked? • • Has the filter system been installed away from heavy traffic areas? To change the filter: • Is the system installed securely to the mounting surface? • Has the water supply line been checked for suitability? (Refer to Water Service section, page 7).
Troubleshooting Please use Troubleshooting Guide to repair system. If system still does not work properly, contact Manitowoc Service for assistance. A leak may occur at the inlet/outlet connections because of defective tubing. To repair: • Turn off incoming water supply and depressurize system by removing the filter cartridge(s). • Disconnect the water line by pushing the collet squarely against the face of the fitting. • Pull the tubing to release.
Recommended Replacement Parts List Part # Description K00337 AR-Pre CartridgeAR K00338 AR-10000 Cartridge K00339 AR-20000 Cartridge 7601973 John Guest Collet 7601983 John Guest O-Ring Exploded View AR-Pre, AR-10000, AR-20000 Exploded View AR-40000 Manifold 12
2012