Programming Instructions

Rolling Code Transmitters - Series "100"
Rolling Code Transmitters - Series "100"
Specifications and Programming Instructions
Specifications and Programming Instructions
Commercial Sequence or SBC Programming (Optional)
Modes Functions
Programming
(On operator's ECB)
Commercial
Sequence -
1-Button
OPEN / CLOSE Button
Door is CLOSED:
- Click Button Door OPENS FULLY
During UPWARD Travel:
- Click Button Nothing happens
Door is OPENED:
- Click Button Door CLOSES FULLY
During DOWNWARD Travel:
- Click Button Door reverses and OPENS FULLY
Door is STOPPED:
- Not possible in this mode. Door is either FULLY
OPENED or FULLY CLOSED.
Standard default mode.
1.Door is in fully CLOSED posi
tion.
2.On ECB, verify if the close limit
switch is activated (CLOSE LED is
ON).
3.On ECB, set select switch on
9 = SBC.
4.On ECB, press “STOP” button.
5.On ECB, select run mode
(1, 4, or 5).
Single Button
Control (SBC)
Available with the
Electronic Control
Board (ECB) only.
Alternating
Sequence
OPEN / STOP / CLOSE Button
Door is CLOSED:
- Click Button Door OPENS
During UPWARD Travel:
- Click Button Door STOPS
Door is STOPPED:
- Click Button Door CLOSES
Dur
ing DOWNWARD Travel:
- Click Button Door STOPS
Door is STOPPED:
- Click Button Door OPENS
Note: If the door is STOPPED for more than 2 minutes,
the next movement will be UPWARD regardless of the
previous movement.
1.Door is in fully CLOSED position.
2.On ECB, verify if the close limit
switch is activated (CLOSE LED is
ON).
3.On ECB, set select switch on
9 = SBC.
4.On ECB, press “OPEN” button.
5.On ECB, select run mode
(1, 4, or 5).
For further i
nformation, please consult the operator's Installation & Instruction Manual or contact our Technical
Support Department at
1-800-361-2260
.
1-800-361-2260
www.manaras.com
4 TN1054 REV 0 - 2019/07/25
Rolling Code Transmitters - Series "100"
Rolling Code Transmitters - Series "100"
Specifications and Programming Instructions
Specifications and Programming Instructions
Transmitter Programming: RADIOEM101, RADIOEM102, RADIOEM103, RADIOEM104
The Opera Brand Transmitters can be used as either a 1-Door x 3-Button Transmitter or as a Multiple-Door
Transmitter (Commercial Sequence or SBC). Commercial Sequence or SBC settings depend on the operator
programming settings. The Transmitters can be re-programmed as needs change.
Transmitter Modes and Functions Transmitter Programming
RADIOEM101
1-Door
1-Button Transmitter
(1)
1.OPEN / STOP / CLOSE Only Button
No initial programming is required.
The Transmitters are ready to be matched to the
Receiver of your choice, refer to section Transmitter
to Operator Matching (Pairing), p. 3.
RADIOEM104
4-Door
4 x 1-Button Transmitter
(1)
1.DOOR #1 Top Left Button
2.DOOR #2 Top Right Button
3.DOOR #3 Bottom Left Button
4.DOOR #4 Bottom Right Button
(1)
Each button acts separately as a 1-Button Transmitter.
Commercial Sequence or SBC Programming depends on the Operator Settings, please refer
to the Commercial Sequence or SBC Programming instructions, p. 4).
RADIOEM102
Mini Key Chain
1-Door
3-Button Transmitter
(Factory default for RADIOEM103SD)
1.OPEN Top Button
2.CLOSE Middle Button
3.STOP Bottom Button
1.Press and HOLD Buttons
and for 5 sec.
The RED LED will BLINK.
You have 15 sec. to complete the configuration or
you will need to restart.
2.Release Buttons
and .
3.Press Button
.
4.The RED LED will stop blinking.
Programming is now complete.
RADIOEM103
Single Door (SD) /
Multiple Door
(MD)
3-Door
3 x 1-Button Transmitter
(1)
(Factory default for RADIOEM102 &
RADIOEM103MD)
1.DOOR #1 Top Button
2.DOOR #2 Middle Button
3.DOOR #3 Bottom Button
1.Press and HOLD Buttons
and for 5 sec.
The RED LED will BLINK.
You have 15 sec. to complete the configuration or
you will need to restart.
2.Release Buttons
and .
3.Press Button
.
4.The RED LED will stop blinking.
Programming is now complete.
(1)
Each button acts separately as a 1-Button Transmitter.
Commercial Sequence or SBC Programming depends on the Operator Settings, please refer
to the Commercial Sequence or SBC Programming instructions, p. 4).
1-800-361-2260