Designer Series Direct Vent Gas Fireplace Models: STLDVNS/PS, CLLDVNS/PS, CRLDVNS/PS, PFLDVNS/PS WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. 2381 designer cover – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. – WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance.
CONTENTS Designer Series Direct Vent Gas Fireplace Thank you and congratulations on your purchase of an Vermont Castings Group Fireplace. PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE! IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Important Safety Information......................................3 Electrical Installation........
IMPORTANT SAFETY INFORMATION Designer Series Direct Vent Gas Fireplace OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. WARNING INSTALLER • Read this owner’s manual carefully and completely before trying to assemble, operate, • • or service this fireplace. Any change to this fireplace or its controls can be dangerous.
Designer Series Direct Vent Gas Fireplace IMPORTANT SAFETY INFORMATION & CODE APPROVAL IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY It is not unusual for gas fireplace to give off some odor the first time it is burned.
product features Designer Series Direct Vent Gas Fireplace product SPECIFICATIONS • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. • The appliance is approved for bedroom or bedsitting • • • • room installations. The appliance must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in Canada.
FIREPLACE DIMENSIONS Designer Series Direct Vent Gas Fireplace Centerline of Flue Outlet 12" (305 mm) 11 6M” (298 mm) 47(6 ” (1216 mm) 25 6M” (654 mm) 34” (864 mm) 35 6QE” (903 mm) 41(6 ” (1064 mm) 2856M” (718 mm) 37(6 ” (962 mm) 156M" (32 mm) 3356QE” (840 mm) 3 6QE” (81 mm) 23" (584 mm) 38 6QE” (979 mm) 7(6 ” (200 mm) 49 6QE” (1259 mm) FP2851 Figure 2 STLDV (See-thru) Fireplace Dimensions FP2851 LDV see thru dims Centerline of Flue Outlet 11 6M” (298 mm) 7(6 ” (200 mm) 21” (533 mm) 2
FIREPLACE DIMENSIONS Designer Series Direct Vent Gas Fireplace Centerline of Flue Outlet 11 6M” (298 mm) 7(6 ” (200 mm) 21” (533 mm) 2856M” (718 mm) 25 6M” (654 mm) 47(6 ” (1216 mm) 35 6QE” (903 mm) 41(6 ” (1064 mm) 2856M” (718 mm) 34” (864 mm) 37(6 ” (962 mm) 156M" (32 mm) 156M" (32 mm) 1856O” (470 mm) 12" (305 mm) 556 ” 156 ” (130 mm) (29 mm) 3356QE” (840 mm) 38 6QE” (979 mm) 46 6 ” (1178 mm) 23" (584 mm) 7(6 ” (200 mm) FP2853 Figure 4 PFLDV (Peninsula) Fireplace Dimensions 20302381 Fp2
FIREPLACE FRAMING Designer Series Direct Vent Gas Fireplace 23" (1/2" Drywall) or Adjustable to 22 6M” (5/8” Drywall) Remove box and Insulation for Top Vent Configurations Noncombustible Material CL 7 (17 ” 8m m Min ) . 4 (10 ” 2m m Min ) . 855 (22 6QE” 1m m Min ) . Fold Outer Tabs and Nail to Framing Members 48 6QE” (1224 mm) NOTE: Glass centerline is off center from rought framing dimensions.
FIREPLACE FRAMING Remove box and Insulation for Top Vent Configurations Designer Series Direct Vent Gas Fireplace 4656 ” (1172 mm) (1/2” Drywall) or 46” (1168 mm) (5/8” Drywall) 2756O” (699 mm) (1/2” Drywall) or 27 6 ” (696 mm) (5/8” Drywall) Noncombustible Material 45 (114 6O” mm Min ) . , 6QE” 855 ) Min m m 221 ( 7” ) mm 8 (17 in.
FIREPLACE FRAMING Designer Series Direct Vent Gas Fireplace 23” (584 mm) (1/2” Drywall) or Adjustable to 22 6M” (578 mm) (5/8” Drywall) 4656 ” (1172 mm) (1/2” Drywall) or 46” (1168 mm) (5/8” Drywall) Noncombustible Material Remove box and Insulation for Top Vent Configurations 48 6QE” (1224 mm) , 6QE” 855 ) Min m m 221 ( 7” ) m 8m (17 in.
pRE-INSTALLATION INFORMATION Designer Series Direct Vent Gas Fireplace Before You Start firebox framing Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received.
pRE-INSTALLATION INFORMATION Designer Series Direct Vent Gas Fireplace Fireplace Location Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspections.
CLEARANCES Designer Series Direct Vent Gas Fireplace WARNING Clearances to combustibles 12” Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. Noncombustible Material to Top of Standoffs 6” 16” The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring.
VENTING INSTALLATION WARNING Designer Series Direct Vent Gas Fireplace Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life. installation precautions Consult local building codes before beginning the installation.
VENTING INSTALLATION Screws Flue Pipe Cover WARNING Designer Series Direct Vent Gas Fireplace After conversion to top vent configuration, the 5" (127 mm) flue pipe should be concentric with the 8" (203 mm) outer collar within 1/4". Flue Cover Screws Flue Pipe Adapter FP2833 Figure 12 Remove 16 screws from Flue Pipe Adapter and Flue Pipe Cover 4. Remove six (6) screws securing the flue pipe to the back of the intake box and remove the pipe and gasket. Figure 13 5.
VENTING INSTALLATION This fireplace must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems.
Venting installation It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness. for horizontal termination Select the amount of vertical rise desired. All horizontal run of venting must have 1/4" rise for every 12" of run towards the termination below 7Z\x' of vertical rise from floor of fireplace. With 7Z\x feet or more of vertical rise from the floor of the fireplace, the horizontal run may be level.
venting installation Designer Series Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL V G H A D L V E C B V F Figure 16 Termination Locations Ope B V Operable rable V B B V V Fixed Closed J A CFM145a V VENT TERMINATION B Fixed Closed X AIR SUPPLY INLET X B M I V K X AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations1 US Installations2 A = Clearance above grade, veranda, porch, 12” (30 cm)CFM145a 12” (30 cm) D
venting installation Designer Series Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Alcove Applications* Inside Corner Outside Corner G= Combustible 6" (152 mm) G Noncombustible 2" (51 mm) V F= Combustible 6" (152 mm) Noncombustible 2" (51 mm) V C V O F Balcony with perpendicular side wall Balcony with no side wall D C E E = Min. 2” (51 mm) for non-vinyl sidewalls Min.
venting installation Designer Series Direct Vent Gas Fireplace REAR WALL VENT INSTALLATION (5" x 8" VENTING ONLY) When installed as a rear vent unit, this appliance may be vented directly to a termination located on the rear wall behind the appliance. Only an Vermont Castings Group brand termination is allowed for this application. • The maximum horizontal distance between the rear of the appliance and the termination is 20" (508 mm). Figure 19 Maximum 20" (508 mm) 2.
venting installation Designer Series Direct Vent Gas Fireplace Vent Cap Inerior Wall Surface Vent Cap (Horizontal Termination) Firestop T HO Apply Mastic to all Four Sides FP1957 Wood Screw Figure 22 Install Horizontal Termination Screw Figure 24 Install Firestop on Horizontal Vent Pipe 5DT-VS (Not required for Vermont Castings Group termination) Termination T HO FP1956 Nut Do not recess vent termination into any wall. This will cause a fire hazard.
venting installation WARNING Designer Series Direct Vent Gas Fireplace When installing the appliance as a rear vent unit, the 90° or 45° transition elbow attached directly to the rear of the unit is NOT INCLUDED in the following criteria and calculations and, unless specifically mentioned, should be ignored when calculating venting layouts.
venting installation Designer Series Direct Vent Gas Fireplace B 7' A 10' Horizontal 90° Elbow = 3' Reduction 7'6" A + B = 17' Maximum Horizontal with vertical rise (through-the-wall) applications 1. Locate and cut the vent opening in the wall. For combustible walls first frame in opening. Combustible Interior Walls: Cut a 12Z\x"H x 10Z\x" W hole through the interior wall. Combustible Exterior Walls: Cut a 10Z\x"H x 10Z\x"W square hole through the exterior wall frame.
venting installation Designer Series Direct Vent Gas Fireplace 1. Locate and cut the vent opening in the wall. For combustible walls first frame in opening. Combustible Interior Walls: Cut a 11Z\x"H x 9Z\x" W hole through the interior wall. Combustible Exterior Walls: Cut a 9Z\x"H x 9Z\x"W square hole through the exterior wall frame. Figure 31 Noncombustible Walls: Hole opening should be 7Z\x" (190 mm) in diameter. 2.
venting installation Designer Series Direct Vent Gas Fireplace NOTICE vertical through-the-roof applications A restrictor disc must be installed on vertical terminations that are higher than 12' (366 cm). 10' Maximum 40' Maximum Height 8' Minimum Height Install restrictor disc as shown in Figure 34 for vertically vented applications. Up to two (2) restrictor discs may be needed for 40' installation. Support Straps Every 3' The two (2) restrictor discs suppled will work for most installations.
venting installation Designer Series Direct Vent Gas Fireplace Roof Flashing 1 2 3 Wall Strap 4 45° Elbows 1 2 Elbow 1 Elbow 2 Elbow 3 Elbow 4 Total Angular Variation Example: = = = = = 90° 45° 45° 90° 270° 4 Ceiling Firstop Figure 37 Offset with Wall Strap and 45° Elbows flat ceilingFP1969 installation offset wallstrap 1. Cut a 10Z\x" (267 mm)w/ square hole in the ceiling using Figure 36 Maximum Elbow Usage INSTALLATION FOR VERTICAL TERMINAFP2309 TION max elbow use A 1.
venting installation Designer Series Direct Vent Gas Fireplace Nails NOTE: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclosure with standard construction material. Make sure to meet the minimum allowable clearances to combustibles. Do not fill any of the required clearance spaces with insulation.
FLEX vent installation Designer Series Direct Vent Gas Fireplace 1. Flexible UL1777 listed venting may be used in any venting application where rigid direct vent components can be used. All restrictions, clearances and allowances that pertain to the rigid piping apply to the flexible venting. Flex kits may not be modified. Flex kits may be added to the end of a vent run made of rigid vent sections using pipe manufacturer's approved flex to pipe adapters.
FLEX vent installation Designer Series Direct Vent Gas Fireplace D. Attaching flexible venting to vertical termination assemblies. 1. When using Duravent pipe, an Vermont Castings Group flex-to-pipe adapter and/or rigid pipe section(s) is required to connect the flexible vent assembly to the vertical termination by using three self-penetrating screws. 2. Review Figure 44 and corresponding instructions for proper overlap, clamp and screw placement. 3.
FLEX vent installation Designer Series Direct Vent Gas Fireplace 4" x 7" Flex Pipe If you prefer to use 4" x 7" flex pipe, you must install model 7TDVP58 reducer (5" x 8" to 4" x 7") onto the fireplace collar. Then follow the the assembly guidelines for 5" x 8" flex venting. UL1777 Flex Vent 1C\v" Flexible Pipe and Adapter Outer Gear Clamp 5" x 8" to 4" x 7" Adapter (7TDVP58) Screws (3 places, equidistant just above gear clamp) Appliance Starting Collar FP1972a Figure 46 Typical 4" x 7" Appliance Co
fireplace installation Designer Series Direct Vent Gas Fireplace check gas type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace according to your gas type. External Regulator WARNING Installing gas piping to fireplace location A qualified installer or service person must connect appliance to gas supply. Follow all local codes. 100 gal.
fireplace installation Designer Series Direct Vent Gas Fireplace CAUTION WARNING GAS SUPPLY LINE INSTALLATION Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. NOTE : The gas line connection may be made using 1/2" rigid tubing or an approved flex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the National Fuel Gas Code ANSI.Z223.1, NFPA54.
CHECK GAS PRESSURE and ELECTRICAL INSTALLATIONDesigner Series Direct Vent Gas Fireplace Pressure Inlet FP1909a Pressure Outlet Pilot Adjustment Screw Figure 52 Signature Command Valve WARNING 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. 2.
ELECTRICAL INSTALLATION Designer Series Direct Vent Gas Fireplace JUNCTION BOX WIRING 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing codes. 2. Remove the external junction box cover by removing the screw from the side of the outside firebox wall. Junction box was installed at the factory. 3. The junction box cover has a factory installed “romex” style strain relief connector.
ELECTRICAL INSTALLATION Designer Series Direct Vent Gas Fireplace Optional AC Module To Junction Box in Fireplace Pilot { Plug in Connector Optional Blower Optional Light { White Black White Black Optional { White Black Aux. Green Connector Pin To Control Board Input 300 Watt Max.
Optional fan blower system The black and white wires on the AC box wiring harness are marked ‘Blower’, ‘Light’ and ‘Aux’. It is important to use the wires marked ‘Blower’ or the control will not work correctly. WARNING WARNING Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
OPTIONAL FAN BLOWER SYSTEMS Designer Series Direct Vent Gas Fireplace BLOTBLDV AUTOMATIC DUAL THERMOSTAT BLOWER 120VAC Receptacle Junction Box BLACK GREEN WHITE BLACK WHITE BLACK BLACK Speed Control Figure 56 BLOTBLDV Blower Wiring Diagram FP2685 Before installing the blower, wire the receptacle into an electrical circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance FP2685 with prevailing codes.
glass removal Glass Frame Removal 1. Remove access panel by lifting up and out. 2. Release two clamps (500 model has three clamps) on bottom of fireplace. Figure 58 3. Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace. 4. Set glass frame aside. CAUTION Designer Series Direct Vent Gas Fireplace Each clamp has a quick spring force. When reinstalling clamps, keep fingers clear.
final installation Designer Series Direct Vent Gas Fireplace ROCK WOOL PLACEMENT Place rock wool evenly in dime-sized pieces over the burner ports. Do not place embers over the burner slots. To better enable the gas to permeate the rock wool, apply the rock wool in light, dime size fluffy pieces.
log placement Designer Series Direct Vent Gas Fireplace LOG PLACEMENT Log #1 1. Hold log #1 with the rounded end opposite the pilot. NOTE: Log #1 is designed to not be symmetrical. Place log #1 aligning the two (2) pins provided making sure to fit the notches in the bottom of the log over the sides of the grate so that it sits firmly in place. The log will rest on the grate bar about 1/4" over the top of the burner surface. Figure 60 Figure 60 LG965 Log #2 LG965 designer BV log #1 2.
log placement Designer Series Direct Vent Gas Fireplace Log #3 False-Bottom Hearth LG967 3. Position log #3 on the key provided on the rounded end of log #1. The other end sits on the "false-bottom hearth" (the sheet metal surrounding the burner and supporting the grate), just outside of the grate. The base of the log should be about 1" from the end of log #2. Figure 62 Figure 62 LG967 designer DV log 3 4.
log placement Designer Series Direct Vent Gas Fireplace 5. Place log #5 on the key provided on log #4. Rest the other end of the log on the "false-bottom hearth" just outside of the grate. It should be almost touching the end of log #1.
OPERATING INSTRUCTIONS Designer Series Direct Vent Gas Fireplace WARNING for your safety read before lighting If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of lie. A. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions. B. BEFORE OPERATING smell all around the appliance area for gas.
OPERATING INSTRUCTIONS Designer Series Direct Vent Gas Fireplace OPERATing INSTRUCTIONS 1. STOP! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. With five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on Page 43. If you do not smell gas, go to next step. 4.
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS Designer Series Direct Vent Gas Fireplace FEATURES RF Receiver ON/OFF Command Center To Thermopile To Sensor • Easy Access Function Operation and System Configura- tion • Operation Confirmation/Fault Diagnostic Indications (LED/ Buzzer) • ON/OFF/HI/Med/Low Operation • Optional Wall Mounting Control Board To Sparker NG/LP Conversion Control Board • Electronic Ignition • Pilot Lockout safety feature • Electric Power Regeneration from Thermopile to save
Designer Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS SYSTEM CONFIGURATION/SETUP All System configuration/setup is done on the Command Center. NOTE: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center. COLD CLIMATE OPTION Choose the Mode That Best Suits Your Needs The Signature Command System is designed to operate in either Standing Pilot or Intermittent Pilot mode.
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS Designer Series Direct Vent Gas Fireplace FUNCTIONS/OPERATION Turning on the fireplace 1. Turn on the master switch and wait for a beep. 2. Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High setting or last memory setting (See Turning Off Fireplace below). For memory feature. Pilot Safety Lockout Function 1. If the pilot doesn’t light after sparking for 30 seconds, pilot trial lockout happens.
cleaning and maintenance WARNING Designer Series Direct Vent Gas Fireplace Sensor Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season Thermopile Burner, Pilot and Control Compartment Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year.
cleaning and maintenance Vent SysteM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function. Glass Door Thoroughly clean the inside of the glass door after using the fireplace for ten hours. Periodically clean the glass door as necessary.
troubleshooting Designer Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION Install batteries and/or plug in the AC board FAULT No beep in about 8 seconds A Using battery? Make sure Command Center and the control board are connected by a 2 feet or 15 feet cable After the beep Flip the master switch (rocker switch) to the ON position Press the ON button on the Command Center No beep or no sound from the valve indicating pilot solenoid open B No sparking on the pilot C Sparking
REPLACEMENT PARTS Designer Series Direct Vent Gas Fireplace 3 1 5 2 4 firebox components Item Description 1. Glass Frame Assembly 2. Access Panel 3. Glass Frame Assembly, Short 4. Access Panel, Short 2381 5. Grate firebox parts 6. Junction Box Assembly (not shown) 20302381 ST Qty. 2 2 --1 1 PF CR/CL Qty. Qty.
REPLACEMENT PARTS Designer Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM 1 12 2 3 13 4 7 15 16 6 5 11 9 8 2381 LDV SCS burner parts 52 20302381
REPLACEMENT PARTS Designer Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM Item 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. Description Qty. Burner Assy 1 Venturi Gasket 1 Venturi Assy 1 Injector 1 Tube, Union to Venturi 1 Fitting Brass - Union 5/16 Compression 1 Tube, Elbow to Union 1 Fitting, 5/16 x 3/8 Brass Male 1 Valve SCS 1 Bolt M5-.
REPLACEMENT PARTS Designer Series Direct Vent Gas Fireplace logs 2 1 3 5 4 Item 1. 2. 3. 4. 5. 54 Description Log #1 Log #2 Log #3 Log #4 Log #5 Qty.
REPLACEMENT PARTS Designer Series Direct Vent Gas Fireplace BRICK 2 1 Ref. 1. 2. 3. 4.
REPLACEMENT PARTS Designer Series Direct Vent Gas Fireplace VENT components 1 7 4 8 9 HO T 5 2 3 6 11 10 0004 MLDV vent parts 56 20302381
VENTING COMPONENTS Designer Series Direct Vent Gas Fireplace VENT COMPONENTS FOR 4" X 6B\," Current Duravent or Vermont Qty./ Castings Group Item Box Description Part no.
Designer Series Direct Vent Gas Fireplace VENTING COMPONENTS VENT COMPONENTS FOR 5" X 8" Current Old Duravent Duravent or Vermont or Vermont Qty./ Castings Group Castings Group Selkirk Metal-Fab Item Box Description Part no. Part no. Part no. Part no.
VENTING COMPONENTS Designer Series Direct Vent Gas Fireplace HORIZONTAL VENTING - 4" x 7" Horizontal Vent Termination Kits Description Model Number Rear Vent Hot Touch Termination Kit w/ 10" to 16" 7TBRHTK Adjustable Termination Pipe, Firestop, and Hot Touch Termination w/ Siding Shield Up and Out Side Wall Termination Kit w/ 10" to 16" 7TDVSCTK Adjustable Termination Pipe, 90° Elbow, Firestop, and Cool Touch Termination w/ Siding Shield Rear Vent Cool Touch Termin
Designer Series Direct Vent Gas Fireplace VENTING COMPONENTS VERTICAL VENTING - 4" x 7" Description Vertical Vent Termination Kits Model Number Vertical Vent Termination w/ Storm Collar (flashing NOT included) 7TDVSKV Vertical Vent Termination w/ Storm Collar - 8 pack (flashing NOT included) 7TDVSKV/8 Vertical Vent Termination w/ 1/12 - 6/12 Flashing, Storm Collar and Ceiling Support Kit 7TDVSKVA* Vertical Vent Termination w/ 6/12 - 12/12 Flashing, Storm Collar and C
Designer Series Direct Vent Gas Fireplace 20302381 61
Designer Series Direct VentCommonwealth Gas Fireplace Requirements for the of Massachusetts This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Note Regarding Vented Products Flex line installation must not exceed 36 inches and must have a T shutoff valve. Any residence with a direct vent product must have a CO detector installed in the residence.
Designer Series Direct Vent Gas Fireplace Limited lifetime warranty policy Lifetime Warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. Five Year Warranty The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
Designer Series Direct Vent Gas Fireplace Based on CSA P.4.1-09 Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) Natural Gas 69.7 LP/Propane 79.4 D.O.E. (AFUE%) 67.0 68.3 Recherchez dans la brochure les caractéristique de rendement énergétique de foyer au gaz Énerguide Based CSA P.4.1-09 Selonon CSA P.4.1-09 Vermont Castings Group 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.