ME AGS Auto Gen Start Network System with Inverter and Remote for Coach Generators Operators Manual
ME AGS Operators Manual Auto Gen Start Network System with Inverter and Remote for Coach Generators Table of Contents Section 1. 2. 3. 4. 5. 6. 7. Overview Configuration Installation Operation Specifications Troubleshooting Warranty Page 2 3 5 12 14 15 16 SAVE THESE INSTRUCTIONS This manual contains important safety instructions. 2004 - Magnum Energy, Inc.
1.
2. Configuration 1. Configuring the AGS Controller The Magnum AGS Controller can be configured for 12 or 24 VDC operation. It can also be configured for various diesel or gas generator brands and models. The controllers default settings are set for "12 VDC" and "Diesel" operation. If necessary, refer to Table 1 (next page) to determine which setting is correct for your system. To access the jumpers, remove the controllers four cover screws.
2. Configuration VERSION V 2.0 V 2.
3. Installation Installing the AGS Controller In most cases, the Auto Gen Start (AGS) Network System with Inverter and Remote has been installed by the coach manufacturer. 1. Determine a suitable location to mount the Auto Gen Start (AGS) Controller. It must be located in a clean, dry and protected place. The controller can be mounted in any direction; however, allow ample room to access the adjustment dials and to view the LEDs for troubleshooting.
3. Installation Installing the AGS Interior Temperature Sensor WARNING: Always check for hidden wires, pipes and cables before drilling or cutting into the coachs walls and cabinets. There are three options for installing the AGS Interior Temperature Sensor which are all used in conjunction with the ME-RC remote control. You must specify which option you would like when ordering your Magnum AGS system or call the factory to order if your system did not come with the desired option.
3. Installation 4. Plug the other end of the 6 wire phone cable into the AGS Controllers RJ-11 connector marked "Remote." 5. If all wiring is correct, the unit performs a "self test" when power is applied. The "STATUS" LED blinks green. At the same time, the "READY" LED turns on solid green. 6. Reconnect the generators spark plug (or reconnect the battery for diesel generators). 4-wire Cable w/Temperature Sensor Installation (option) 1.
3. Installation 4 Wire Twisted Pair Cable ME Series Inverter 4 Wire Sensor Cable AGS Controller AGS Controller AGS Sensor 1 2 3 4 5 6 7 8 Aux Aux Remote GEN Hour Meter - + Start 5 Amp Comm Ground Stop Fuse + GEN Start/Stop Switch - 12 VDC Battery Ground Figure 3 - AGS Wiring Diagram 8 2004 - Magnum Energy, Inc.
3. Installation Note: Pin #1 is located on the LEFT side facing the terminal block 1 2 4 Wire Connector to Sensor 6 Wire Connector to Inverter 3 4 5 6 7 8 Aux Contact Generator Stop / Preheat Common from Generator Start / Stop Switch (Ground) Generator Start - 12 VDC (Negative) from Battery + 12 VDC (Positive) from Battery Generator B+ (+ 12 VDC) from Generator Hour Meter Aux Contact Figure 4 - AGS Connector Pin Legend (from left to right) 2004 - Magnum Energy, Inc.
3. Installation The AGS comes preset for voltage, temperature and generator run time directly from the factory. Quiet Time is factory preset to "OFF" (defeated). For the majority of customers, no adjustments are necessary. If you need to make changes to the factory adjustments, you can do so by rotating the knobs on the AGS Controllers front panel (refer to next page) 1. The "START TEMP F" factory setting is set at 75 °F (25 °C).
3. Installation 5. "QUIET TIME" is a program that prevents the generator from starting during specific hours of the evening and early morning. It is adjustable for five pre-selected time ranges. To set quiet time, turn the dial either counter-clockwise or clockwise to the hours required: 9-7 (9 PM to 7 AM), 9-8 (9 PM to 8 AM), 9-9 (9 PM to 9 AM), 10-8 (10 PM to 8 AM), 11-8 (11 PM to 8 AM). The program only needs to be set once.
4. Operation The AGS Remote Control is equipped with a wide range of easy-to-use switches and displays, allowing you to quickly setup your inverter/charger as well as determine its operational status. The "AGS" soft key controls the operation of the networked AGS Controller (refer to figures on page 11). Rotary SELECT Knob Similar to a dash radio knob, use the SELECT knob to move between menus and select program options. Turn the knob clockwise to increase value or counter-clockwise to the decrease value.
4. Operation WARNING: Set the AGS to "AutoGenSt OFF" before servicing the electrical or generator system. NOTE: It is recommended that the AGS be set to "AutoGenSt OFF" while storing or leaving the coach unattended for extended lengths of time. This setting is also recommended whenever the coach is plugged into shore power. 1. Set the air conditioner thermostat to match the AGS "START TEMP F" setting.
5. Specifications Weight (Controller) 1 lb (0.5 kg) Weight (Switch) 0.25 lb (0.1 kg) Dimensions (Controller) 3.0 H x 5.2 W x 1.33 D (7.6 cm H x 13.2 cm W x 3.3 cm D) Dimensions (Switch) 2.25 H x 3.25 W x 1.5 D (5.7 cm H x 8.3 cm W x 3.
6. Troubleshooting To test the system for proper operation, hold the AGS Switch in the "TEST" position and release. The generator should start and run for 30 seconds and then shut off. If the generator does not start and stop as expected, refer to the troubleshooting chart below. If the problem persists, contact your dealer. LED INDICATION RED = GEN FAULT SYMPTOM Gen won't start. OPERATION/SOLUTION Check Gen start wiring, Turn "off" then "enable" to reset.
7. Warranty 36 Month Limited Warranty Magnum Energy, Inc., warrants the ME Series Auto Gen Start to be free from defects in material and workmanship that result in product failure during normal usage, according to the following terms and conditions: 1. The limited warranty for the product extends for 36 months beginning from the product's original date of purchase. 2. The limited warranty extends to the original purchaser of the product and is not assignable or transferable to any subsequent purchaser. 3.
Remote Switch (option) 1-5/8” Cutout 2-1/8” 1-1/4” 7/64” Drill Bit 5-1/4” 4-3/4” Cut Out Area 2-3/4” Remote Control Templates 1/8” Drill Bit 3-1/4”
Magnum Energy, Inc. 1111 80th Street SW - Suite 250 Everett, WA 98203 p: 425.353.8833 f: 425.353.8390 p/n 64-0005 rev.