MANUAL IMPAC Pyrometers IS 6-TV Advanced · IGA 6-TV Advanced · ISR 6-TV Advanced Addendum to IS 6 Advanced, IGA 6 Advanced, and ISR 6 Advanced Manuals
Confidential Information The material contained herein consists of information that is the property of LumaSense Technologies and intended solely for use by the purchaser of the equipment described in this manual. All specifications are subject to change without notice. Changes are made periodically to the information in this publication, and these changes will be incorporated in new editions.
Contents 1 General Information...................................................................................................... 5 1.1 Information about the user manual..................................................................... 5 1.1.1 Legend ................................................................................................................. 5 1.1.2 Terminology ........................................................................................................ 5 1.2 Safety ..
To ensure consistent document formatting, this page was intentionally left blank.
1 General Information 1.1 Information about the user manual Congratulations on choosing the high quality and highly efficient IMPAC Series 6-TV Advanced pyrometer. This manual provides important information about the instrument and can be used as a work of reference for installing, operating, and maintaining your Series 6-TV Advanced pyrometer. It is important that you carefully read the information contained in this manual and follow all safety procedures before you install or operate the instrument.
The warranty is VOID if the instrument is disassembled, tampered with, altered, or otherwise damaged without prior written consent from LumaSense Technologies; or if considered by LumaSense Technologies to be abused or used in abnormal conditions. The Windows compatible software was thoroughly tested on a wide range of Windows operating systems and in several world languages.
Return the instrument upon receipt of the RMA number, transportation prepaid. Clearly indicate the assigned RMA number on the shipping package exterior. Refer to Section 1.6, Shipments to LumaSense for Repair, for shipping instructions. Technical Support can be contacted by telephone or email: Santa Clara, California Frankfurt, Germany Erstein, France Telephone: +1 408 727 1600 +1 800 631 0176 Telephone: +49 (0)69-97373 0 Telephone: +33 (0)3 88 98 98 01 Email: support@lumasenseinc.
To ensure consistent document formatting, this page was intentionally left blank.
2 Introduction 2.1 Technical Data (Different from IS 6 Advanced / IGA 6 Advanced / ISR 6 Advanced) Video-Signal: Date/Time: Connection of Video-Signal: Operating ambient temperature: FBAS-Signal ca.
2.
3 Electrical Installation 3.1 Video Output Electrical Connection On the back cover of Series 6-TV Advanced pyrometers, there is an additional coaxial connector for the video output. LumaSense offers ready-made video connection cables in various lengths, which are fitted with a BNC connector and a BNC-RCA adapter to connect to a monitor or video grabber. Triaxial video-output Focus adjustment set screw 4 digit LED display 12-pin connector Rear View of the Pyrometer 3.1.
Operating Mode The two dots above the letter “T” show the selected operating mode (ISR 6-TV Advanced only). · · · 2-channel mode: 2 dots displayed. If the signal falls below the set Relative Signal (see "Relative Signal" in ISR 6 Advanced Manual), the temperature displayed on the image will be flashing. 1-channel mode: only the left dot is displayed. Metal mode: the left dot is displayed continuously, the right dot flashes.
4 Software InfraWin Using a PC and the InfraWin 5 software (included in scope of delivery), the video image and display options can be configured. 4.1 Set Video Mode Parameters 1. Choose TV for setting the parameters of the video module. 2. Complete the following fields on the screen: · Text: Enter user text (e.
· Manual - the brightness of the video image can be set manually using the slider at the right side of the video image. · Automatic - the brightness of the video image is automatically controlled. Using the two sliders (red and blue) at the right side of the video image, a range of brightness can be set where the automatic control should work. With the yellow button, the selected range can be moved.
Comparison between manual and automatic control of brightness: The measuring temperature was changed for the image recording from the beginning of the measuring range to 1200 °C.
To ensure consistent document formatting, this page was intentionally left blank.
5 Accessory (optional) 5.1 Video Grabber (Converts Analog TV to USB) Using the video grabber (optional accessory) in conjunction with the software InfraWin 5, it is possible to see the video image on the PC screen together with the temperature graph. The video image can be size adjusted and positioned at any place of the screen. The properties of the pyro's video chip as well as properties of the video grabber can be adjusted with InfraWin 5. 5.1.
5.1.2 Adjusting Video Output Settings 1. Select Grabber input. 2. Currently, only “PAL_B” is supported. 5.1.3 Viewing the Video Image During a temperature measurement of the pyrometer, the video image can be displayed on the screen by pressing the TV button. The video image can be positioned anywhere on the screen. Use the slider to change the brightness of the image during the measurement.
6 Data format Universal Pyrometer Protocol (UPP): Extended for Video Module Software commands can be exchanged directly with the pyrometer through an interface using suitable communication software or by using the Test function located in the Pyrometer Parameters window of the InfraWin software package.
Description v00 Command v00XX v01 v01 v01XXXYYY v01? v02 v03 v05 v06 v05 v06 v06nnS v06? v07 v07 v08 v08 v08XX v08? v09 v09 Series 6 – TV Advanced Manual Parameters Text fade in, set value. XX=00..
Description v10 Command v10 v10ABCD Parameters Text properties parameter, read. Answer 4-digit, hex. Text properties parameter, write. A: text color (0..F) B: text transparency (0..7 à 0: transparent; 7: full opacity) C: background color (0..F) D: background transparency (0..
Description v24 Command v24 v24XXYY v25 v26 v27 v31 v24? v25 v26 v26hhmmss v26? v27 v27DDMMYY v27? v31 v31x v31? v32 v32 Series 6 – TV Advanced Manual Parameters Control limit, for automatic brightness read. Answer: XXYY (4-digit, hex) Control limit, for automatic brightness write. XX: bottom Control limit (00..FFhex) YY: top Control limit (00..
7 Reference Numbers 7.
3 820 840 3 820 550 25m connection cable with right angle connector 30m connection cable with right angle connector 3 826 510 PI 6000: PID programmable controller, very fast, for digital IMPAC pyrometers 3 826 720 USB to RS485 adapter cable, 1.
Index A Accessories 17 T B Technical Data 9 Transport 6 Brightness control 9, 13 D Data format UPPÒ 19 Dimensions 10 Disposal 7 G General Information 5 Grabber settings 17 L Legend 5 Liability 5 U Unpacking the Instrument 6 UPPÒ data format 19 V Video Grabber 17 Video Image 11 Video Mode Parameters 13 Video Output Electrical Connection 11 W Warranty 5 O operating mode 12 P Packing 6 R Reference numbers Accessories 23 Instrument 23 Reference Numbers 23 Repair 6, 7 Resolution 9 S Safety 5 Servic