STOCK BOX USER MANUAL Tel: 972-9-835-4848 Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504 Israel LogiTag Systems LTD. www.logi-tag.
Product name p/n STOCKBOX™ user manual Document p/n date LT-D-0101 14/11/2011 Product rev. A01 Document rev. Author name 01 Documents changes and version Date Name Change description 14/11/2011 Golan K Document release Tel: 972-9-835-4848 Fax: 972-9-865-6262 Golan K. version 01 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504 Israel LogiTag Systems LTD. www.logi-tag.
1. Safety Instructions / Warning - Read before start-up ! The device may only be used for the purpose intended by the manufacturer. The operation manual should be kept readily available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude the manufacturer from any liability.
2. System description and operation The STOCKBOX is a system for automating reordering operations in healthcare, manufacturing and other environments. By pre-encoding stock-cards carrying 13.56MHz RFID transponders (ISO-15693) and placing them in bins at the reordering level, users can perform a reorder operation by simply placing the card into the StockBox. The StockBox is designed to identify the cards inserted through its slot, and send the data to a remote server.
The system has 4 interface connectors: RJ45 adaptor for Ethernet connection D-type 9 pin female connector for RS232 connection power supply: plug connector size of 5.5*2.1mm SMA female connector for optional GPRS module antenna 2.1 LED Display And Button Led indicators: Power – LED is on when StockBox is connected to power. Com – LED is on when Ethernet interface is connected.
2.2 Power Supply Connection Allowed supply voltage: 12-24V +/-5%. System's DC supply connector: male jack size 5.5*2.1mm. Use of higher supply voltage can damage the system!! Use only authorized class B power supply certified device. The current consumption of the device (with GPRS connection) is 0.3A@12V. 2.3 Ethernet connection Use CAT5E cable, shielded SFTP. 2.
2.7 System operation: To operate the system: 1. Connect power supply to the power plug and see that the Power LED is ON. 2. Connect LAN or RS232 port to the host computer (section 2.3 and 2.4). 3. Run the StockBox software at the host computer 4. Insert transponders to the slot and see that the "Read" LED is ON 5. Monitor on the host computer's screen the identified transponders 6. Insert only one transponder at a time. 7. To perform Re-Stock operation: a.
Slot IDENTIFY Tel: 972-9-835-4848 Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504 Israel LogiTag Systems LTD. www.logi-tag.
3. Radio approvals: Product name: StockBox™ FCC ID: Z97-STB01 Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
3.1 EUROPE: 4. System Technical data: Mechanical data: o Dimensions (Wx L x H ) 290*200*180mm o Weight approx. 3Kg Electrical data: o Supply voltage 12-24V +/-5% o Power consumption 3.6VA o RFID transmitting power 0.2W Interface: o Ethernet o RS232 Supporting transponders: o ISO15693 Temperature range: o Operation: -20°C to +55°C o Storage: -20°C to +85°C o Humidity: 5%-70% Tel: 972-9-835-4848 Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.
Applicable standards: o RF approval: o Europe o USA o EMC o Safety Tel: 972-9-835-4848 Fax: 972-9-865-6262 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504 Israel LogiTag Systems LTD. www.logi-tag.