English SET UP INSTRUCTIONS Guardian Alert Emergency Wall Communicator Model #41920 This accessory is to be used with the LogicMark’s CaretakerSentry product line. Up to a total of 9 pendants and Emergency Wall Communicators (EWC) can be learned to one LogicMark “DECT” (1.9 Ghz) base unit. CONTENTS: Emergency Wall Communicator (EWC) Double Stick Velcro AAA Alkaline Batteries 4 pieces 2 Screws v3.
TABLE OF CONTENTS Installing the Batteries...............................................................................3 Learning the EWC to the Base of Your PERS System...........................3 Battery Check.............................................................................................4 System Check.............................................................................................5 FCC Information..................................................................................
Installing the Battery Slide the battery cover to the left to unlatch the cover Install the 4 AAA alkaline batteries - noting the polarity on the inside of the battery cover. The spring contacts are meant to touch the negative side of the batteries. Close the battery cover and latch to lock cover. Learning the EWC to the Base unit of Your PERS System.
Notes: • You have up to 45 seconds after pushing the RED Code Learn button on the Base unit to get the EWC to enter “Pendant Learning”. • Learning additional Pendants or EWCs does not erase previously learned Pendants or EWCs. • The Base unit will automatically exit the Pendant learning mode after several seconds or if Pendant learning failed. • Only a combined total of 9 Pendants and EWCs can be learned to a Base unit.
“Battery is ok.” Check the battery condition monthly. “Battery is low.” The batteries should be replaced within the next weeks. “Replace battery now.” The 4 AAA batteries should be replaced now with 4 new AAA alkaline batteries. Please note: If there is no response after pressing the button for one second or more, the batteries are dead and must be replaced immediately. The battery should be tested at least monthly along with the System Check outlined below.
“System cannot detect dial tone.” The Base unit is not connected to the phone line or can not get a dial tone for some reason. “Base and Pendant out of range.” This confirms one or more of the following: The EWC has malfunctioned. The Base has malfunctioned. The EWC and Base unit are not communicating with each other or are out or range. Caution - To ensure proper operation, this equipment must be installed according to the these instructions.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
ONE YEAR LIMITED WARRANTY LogicMark, LLC warrants to the original consumer/purchaser that this product shall be free of defects in material and workmanship under normal use and circumstances for a period of one (1) year from the date of original purchase for use.
Product Specifications: RF Characteristics: 1.9 Ghz DECT Communication Technology Operating Range Should cover your typical American house - but needs to be tested after installation. Batteries 4 AAA Alkaline. Replace every 6 months Water-resistance Water Spray Standard IPX5 (shower only). Number of Products/Base Unit Up to a total of 9 Pendants and Emergency Wall Communicators can be programmed to one Base unit. Operating Temperature 32˚ to 120˚ F. (0˚ to 49˚ C).