User's Manual

Table Of Contents
2
or Disconnect Battery
IDENTIFY POWER
CONNECTION POINT
AND ISOLATE SUPPLY
Fuse
Remove fuse
Vehicle batteries contain gasses
which are flammable and explosive.
Wear eye protection and do not lean
over battery while disconnecting. Do
!
WARNING
1. The Receiver is designed to carry a maximum of 15 Amps. That is, for example,15 Amps
through one output or 5 Amps each through 3 outputs.
2. Master Output. This can be configured to Continuous or Parallel operation, see overleaf for
details.
3. If Receiver outputs are connected in parallel with an external switching device (wired remote)
the Receiver will instantly switch off when the wired remote is operated
4. Lodar Receivers have an isolation switch for safety, to allow for registering a MUST
replacement Transmitter.
5. Safety Feature. Both the Transmitter and the Receiver will “time out” after 30 minutes of
inactivity. This can be altered, ask your dealer.
1
!
BEFORE YOU START
Wiring Instructions for 2 & 4 Function, 92 & 93 Series, FET Receivers.
92 02/4 RX
& 93 02/4 RX
have
7 core cable
CONNECT
WIRES
4
Transmitter
Function
Convention
92 00 RX
& 93 00 RX
have
4 core cable
www.lodar.com
9000
F1 F2
F3
F4
5
or re-connect Battery
ACTIVATE THE
RECEIVER SUPPLY
Fuse
Replace fuse
Press the Transmitter buttonRESET
to activate the system, and carefully
test each function for correct operation.
7
TEST
6
CONNECT TRANSMITTER BATTERY
Batteries generally have to be
disconnected when shipping.
3
Secure using 5mm (3/16") bolts (not supplied)
through the 4 mounting feet
TAKE TIME TO LOCATE THE BEST POSITION
If necessary, power the Receiver and move it around
the vehicle until the required performance is achieved.
Operate the Transmitter and observe the Receiver
internal LED’s.
Mount as HIGH as possible
AVOID surfaces with HEAVY VIBRATION
AVOID DIRECT SPRAY from wheels
In a HOT CLIMATE fit in a SHADED position
Cable gland should face DOWN or BACK
Receiver 92 04 RX and 93 04 RX shown,
Waterproof to IP67, complete with 3 metres (10 ft) cables
CAUTION
MOUNT RECEIVER
STOP
POSITIVE
NEGATIVE
!
12/24 Volts DC Nominal
Positive Supply
RED
Negative
BLACK
GREEN
YELLOW
BROWN
BLUE
WHITE
Output Function 1
Output Function 2
Output Function 3
Output Function 4
Output Function Master
Wire used for
Wire Colour
Not Present
Not Present
Not Present
Not Used
Not Used
9200RX
and 9300RX
9202RX
and 9302RX
9204RX
and 9304RX
Make notes about the
connections made
in the boxes below
What is the MASTER Output for ?
It is used to operate the pump of an electro-hydraulic
power pack or maybe a clutch pump. It can also be
used for powering a dump valve, master valve etc.
It can be configured to work continuously, that is ON
when SET is pressed and OFF when STOP is
pressed; or in parallel with any output, that is, it is
active only a function is operated. If it is needed with
certain functions only, this can easily be configured.
92104.
05 FET 24