DCS 6000 User Manual Digital Conference System PS 6000 Power Supply Danish Interpretation Systems DIS
Danish Interpretation Systems Copyright © 2007 DIS User Manual PS6000 REV B.DOC 21-05-2007 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher.
Danish Interpretation Systems User Manual List of Contents List of Contents..................................................... 3 Important .............................................................. 4 Compliancy........................................................ 4 Safety.................................................................. 4 Installation precautions .................................... 4 Cleaning & Repacking...................................... 4 Warranty ..........................
Danish Interpretation Systems User Manual Important The equipment must be connected to earth Compliancy The equipment has been tested and found to comply with the limits of the following standards for digital devices: • • • • • EN55103-1 (Emission) EN55103-2 (Immunity EN60065 safety UL6500 safety FCC rules part 15, class A (Emission) This device complies with part 15 of the FCC rules.
Danish Interpretation Systems User Manual Description of the DCS 6000 system • Features The DCS 6000 system has the following main features: • Fully digital • Excellent sound quality • “State of the Art” fully digital integrated interpretation, discussion and voting system offering interpretation, language distribution, conference microphone and voting facilities with attendance check with Chip Card ™.
Danish Interpretation Systems User Manual Conference equipment and channel selectors System components The CU 6005/6010 Central Unit supports all available units in the DCS 6000 series: Central equipment etc.
Danish Interpretation Systems User Manual Operating instructions PS 6000 Power Supply • Delayed switching on of power to minimise the total ‘switch-on’ current on the Mains supply. The PS 6000 Power Supply provides additional Power for the DCS 6000 system. • Designed in a small size easy-to-install cabinet. One CU 6005/6010 Central Unit is needed in each DCS 6000 system; however for expansion of the system the PS 6000 Power Supply is suitable.
Danish Interpretation Systems User Manual Use of PS 6000 The PS 6000 can be inserted at any point in a DCS 6000 chain, where extra power is needed. The PS 6000 is used, when extra power is needed typically, where long feeding cables are needed. 8 A typical application is to place a PS 6000 in the first Interpreter Booth to compensate for a long feeding cable.
Danish Interpretation Systems User Manual System Setup General guidelines Connect the PS 6000 to the various DCS 6000 units using Cat5 or Cat5e FTP or STP screened cables. Please observe the following guidelines: • • • Maximum cable length in one chain is 200 m without repeater. This includes interconnection cables between the units. The max. usable cable length depends on the units connected and length of feeding cables etc. Maximum cable length in one chain when using repeaters is 650 m.
Danish Interpretation Systems User Manual Max. number of units to be connected The following tables show the maximum number of units, which can be connected to the two outputs (A1 or A2) on a CU 6005 Central Unit in total or to each of the four outputs (A1, A2, B1 or B2) on a CU 6010 Central Unit or to each output on an EX 6010 Extension Unit or to the output of a PS 6000 Power Supply.
Danish Interpretation Systems User Manual CM/DM 6060F/6510F Chairman/Delegate Units The following tables show the maximum number of units, which can be connected to the two outputs (A1 or A2) on a CU 6005 Central Unit in total or to each of the four outputs (A1, A2, B1 or B2) on a CU 6010 Central Unit or to each output on an EX 6010 Extension Unit or to the output of a PS 6000 Power Supply.
Danish Interpretation Systems User Manual MU 6040 C/D without connected loudspeaker This table shows the maximum number of MU 6040 Microphone Units, which can be connected. The numbers are with no audio in loudspeaker (no loudspeaker connected to each unit). If loudspeakers are used, then use the figures for CM/DM 60x0 above. Length of Feeding Cable, Type CAT5 AWG24 Cable length between each MU 6040 Total cable length Max.
Danish Interpretation Systems User Manual IS 6132P w/JB 6004 and LS 6032 Length of Feeding Cable, Type CAT5 AWG24 Length of cable between booths Number of booths Number of IS 6132/ booths Number of LS 6032/ booths 10 m 10 m 30 m 30 m 50 m 50 m 100 m 100 m 150 m 150 m 5m 5m 5m 5m 5m 5m 5m 5m 5m 5m 19 12 17 10 15 9 11 7 8 5 4 4 4 4 4 4 4 4 4 4 0 4 0 4 0 4 0 4 0 4 CS 6032F Channel Selector w/back light on Length of Feeding Cable Type CAT5 AWG24 Length of Inter-connecting cable, Type CAT5 AWG24 30
Danish Interpretation Systems User Manual Appendix Technical appendix Cabling CAT5 The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors. EIA 568-B wiring shall be used. It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.