FlightConnect Setup Guide Aviation Fueling System LCR 600 FlightConnect DMS FlightConnect FlightConnect Office Liquid Controls Group An IDEX Fluid & Metering Business Operation: EM200-18
Table of Contents Introduction FlightConnect Components..................................2 FlightConnect Overview.......................................4 FlightConnect Setup Overview.............................5 Installation & Setup Install LC Flowmeters...........................................6 Install LCR 600 and DMS (& LCR-II) Units..........6 Setup LCR 600 & DMS (& LCR-II) Units..............6 Install FlightConnect Office & DBManager...........6 Populate FlightConnect Master Database...........
System Components - Introduction FlightConnect System Components (cont’d) FlightConnect FlightConnect fueling Software FlightConnect fueling software can run on a LectroCount LCR 600 or a DMS in-cab computer in conjunction with a LectroCount LCR-II register. LectroCount electronic registers are Weights & Measures approved and mounted onto the meter. LectroCount registers compile metrological data during custody transfers. The DMS is an in-cab computer with a heavy-duty lap pad interface.
Introduction - System Overview FlightConnect Fueling System Overview The FlightConnect Fueling System is an automated data acquisition and data management system designed for into-plane fueling. FlightConnect spans from the point of delivery to the office PC. FlightConnect fueling software, installed onto an LCR 600 or DMS, automatically captures fueling data on the tarmac and transmits the data to the office.
Setup Overview - Introduction FlightConnect Fueling System Setup Overview This document is a guide for the complete installation of a FlightConnect Fueling System. It does not provide specific instructions, but it does provide the correct order of installation steps and references to the manuals that contain specific directions. A FlightConnect Fueling System Setup includes the following steps: 1. Install LC flowmeters 2. Install LCR 600 and DMS (& LCR-II) units 3.
Installation & Setup #1 - Install LC Flowmeters Before installing electronics, Liquid Controls positive displacement flowmeters must be properly installed into the piping system of the refuellers, hydrant trucks, hydrant carts, or other fueling vehicles. Typically, this step is completed by the OEM that built the fueling vehicle.
Installation & Setup #6 - Setup DBManager After the master database is populated, the DBManager program can be set up. This involves registering all of the LCR 600 and DMS units in the FlightConnect network, registering the units in the network with the correct master database (more than one FlightConnect database can be created), and scheduling the LCR 600 and DMS database files for updates (according to changes in the FlightConnect master database.
Liquid Controls 105 Albrecht Drive Lake Bluff, IL 60044 (847) 295-1050 Toptech Systems 1124 Florida Central Parkway Longwood, FL 32750 (407) 332-1774 Nateus Business Park Nieuwe Weg 1-Haven 1053 B-2070 Zwijndrecht (Antwerp), Belguim +32 (0)3 250 60 60 SAMPI Via Amerigo Vespucci 1 55011 Altopascio (Lucca), Italy +39 0583 24751 IDEX Fluid and Metering Pvt. Ltd. Survey No. 256, Alindra Savli GIDC, Manjusar Dist. Vadodara 391 770 Gujarat, India +91 2667 662001 Faure Herman Route de Bonnetable B.P.