USER MANUAL TWINDRIVE ® TD32 / TD33 To learn more about LINAK, please visit: W W W. L I N A K .
Page 2 of 44
Contents Preface .................................................................................................................................................................. Important information........................................................................................................................................ Safety instructions...............................................................................................................................................
Preface We are delighted that you have chosen a product from LINAK A/S. LINAK systems are high-tech products based on many years of experience in the manufacture and development of actuators, electric control boxes, controls and chargers. We are also constantly improving our products to meet customer requirements. This User Manual will tell you how to install, use and maintain your LINAK TWINDRIVE® products. We are sure that the TWINDRIVE® products will give you many years of trouble-free operation.
Important information Important information on LINAK® products can be found under the following headings: Warning! Failure to comply with these instructions may result in accidents involving serious personal injury. Failing to follow these instructions can result in the product being damaged or being destroyed. Safety instruction General Safe use of the system is possible only when the operating instructions are read completely and the instructions contained are strictly observed.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation • Statement – for all intentional and unintentional radiators: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
- Reorient or relocate the receiving antenna. - Increase the separation between the equipment and the receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/ TV technician for help. This device complies with Industry Canada licence-exempt RSS standard(s).
Before installation, de-installation or troubleshooting: • Stop the TD3. • Switch off the power supply and pull out the mains plug. • Relieve the TD3 of any loads, which may be released during the work. Before start-up: • Make sure that the system has been installed as instructed in this User Manual. • Make sure that the voltage is correct before the system is connected to the mains. (See TD3 label in the appendix). • System connection. The individual parts must be connected before connecting to the mains.
Only for EU markets This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Informations importantes Les informations importantes sur les produits LINAK® peuvent être trouvées dans les rubriques suivantes: Attention! Le non respect de ces instructions peut entraîner des accidents impliquant des blessures graves. Ne pas suivre ces instructions peut entraîner l´endommagement ou destruction du produit. Consignes de sécurité Géneral Le non respect de ces instructions peut entraîner des accidents impliquant des blessures graves.
Avant l´installation, ré-installation ou le dépannage: • Arrêtez TD3 • Retirez la prise du secteur • Soulagez TD3 des toutes charges qui pourraient être émises lors de l´utilisation Avant de démarage: • Assurez-vous que le système a été installalé comme indiqué dans le mannuel d´utilisateur. • Assurez-vous que la tension du boîtier de contrôle est correcte avant que le système soit connecté sur le secteur. • Système de connection.
Seulement pour les marchés au sein de l´UE: Cet appareil peut-être utilisé par des enfants âgés de 8 ans et plus, ainsi que les personnes dont les capacités physiques, sensorielles ou mentales sont réduites ou ayant un manque d´expérience et de connaissance si elles ont bénéficié d´une surveillance ou d´instructions concernant l´utilisation de l´appareil en toute sécurité et compris les risques encourus. Les enfants ne doivent pas jouer avec l´appareil.
Repairs In order to avoid the risk of malfunction, all TWINDRIVE® repairs must only be carried out by authorised LINAK workshops or repairers, as special tools must be used and special gaskets must be fitted. TWINDRIVE under warranty must also be returned to authorised LINAK workshops.
Misc. on the TD3 TWINDRIVE® system This system is a TWINDRIVE system developed for leisure beds and for indoor use in private homes. Warranty There is 36 months’ warranty on the TWINDRIVE® products against manufacturing faults calculated from the production date of the individual products (see label). LINAK A/S’ warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with. Furthermore, the system must not be exposed to violent treatment.
Connections CH.1 CH.2 CH.3 Reset Mains inlet Battery drawer Hand Control connection Battery cable/connection Cable relief Connection of massage motors (TD32 series): CH1 CH2 Footrest Headrest Connection CH1, CH2 and CH3 (TD33 series) Massage motors (MD1) LA27 actuators Accessories (LED, DC Connector, USB Connector, Bluetooth2Lin) Mains inlet The mains cable can either be a standard computer power cable or a mains cable with mains cut-off. Both versions are exchangeable.
Cable relief It is important to use the cable relief for the mains cable on the TD3. By using the cable relief you avoid that the mains cable plug is pulled out of the TD3 and a malfunction occurs.
Mounting guidelines for the TWINDRIVE® Place the TD3 below the twist brackets/“arms” of the bed Mount the TD3 and slide the closing devices over the gaps and make sure that the closing devices are in place before the TD3 is used.
Functional description Hand Control HB10RF: Up – down head motor Up – down foot motor Simultaneous up/down Hand Control HB20RF: Up – down head motor Up – down foot motor up to 3 extra channels common operation up/down (option) 1 2 Memory positions (3 positions) 3 S Store Button Light Button How to store • Drive to the desired position • Push “S” • Immediately afterwards the desired memory position must be pushed (1, 2 or 3) • The position is now stored Drive to stored memory position Push (1, 2 or 3)
Start-up - How to install the RF handset: The TD3 can accept commands from up to 2 RF handsets. From the factory the TD3 cannot recognise any RF handsets at all and must be matched to the RF handset(s) by the end-user/bed manufacturer before these can control the TD3 operation.
Connection of LA27 actuators: The TD3 will as default detect and run the LA27 using plug and play rules as illustrated in the table below. The idea is that the Headrest is the first actuator, the Footrest is the second actuator and then the Extra function. The Headrest is always the one nearest to the Backend and the Footrest is always the one nearest to the Leg-end.
Child lock function - only for HB20RF Enable the child lock function: To enable the child lock function the following procedure must be performed: 1. Dismount the battery lid 2. Remove 1 battery and wait for 15 seconds 3. Press both buttons on row 2 and mount the battery at the same time 4. The child lock function is now enabled 5. Mount the battery lid See pictures below: N.B: The child lock function only locks the actuator functions. Therefore, it is disabled when the handset is in massage command mode.
Frequency tuning (FT) HB12RF HB22RF FT (Frequency Tuning): FT is designed to minimise problems with interfering RF frequencies by moving the frequency of the receiver to a more optimal placement relative to the interfering frequency. FT cannot alleviate problems if the interfering RF transmitter is sending on the same frequency as the handsets. The FT has three frequencies it tries out: The centre frequency found during the PCB-test, a frequency a bit lower and one a bit higher.
Disturbance of RF signals: Please be aware that other equipments (as e.g. doorbells), which use the 433 MHz can disturb the RF signal. Under some circumstances it is not possible to run 2 or more TD3s at the same time. Please observe if you place 2 beds/2 x TD3 at a distance below 0.7 m the RF signals may interfere each other and the TD3s can run irregularly. Distance > 0.
Massage systems controlled by HB22RF2000 Usage: Enter/exit massage command mode Pressing this button will toggle the handset from controlling massage functions and bed adjustment. The mode in which the handset is, is indicated by the LED at the top of the handset : LED Flashing – handset is controlling massage functions LED Off – handset is controlling bed functions Pressing this button has no influence on the TWINDRIVE unit except for waking it up so that the response time to massage commands is shorter.
HB22RF2000 in general: • Massage will turn off automatically 10 minutes after the last adjustment of the settings. Default at the TD1 and the TD3. The TD3 can be configured. • Adjusting the bed will turn off the massage, but massage will automatically start up again afterwards. • When turning on a single massage motor it will start up with the same intensity as it was last time it was running as a single motor.
Massage systems controlled by HB22RF2001 On/off (start/stop of the massage) Mode (change between the different massage programs) Controlling the backrest massage motor: Keep the left button pressed to adjust the intensity down and the right button pressed to adjust the intensity up. A short press on the right button turns on the massage motor at current intensity. The massage will run in continues mode while being adjusted.
Massage programs As default the system has 5 massage modes, they are: Hard-wave The massage motors take turns on/off (one on = one off) Soft-wave The massage motors work similar to a wave: when one motor decreases the speed the other motor will increase the speed. Continues in turns like this. Hard-pulse Both massage motors run at the same time. They run from min. to max. speed. Soft-pulse Both massage motors run at the same time. They run from min. to max. speed. From max. speed they drop to min.
Mounting instructions for the massage motor: Mounting on plate: Mounted with 4 screws The massage unit is mounted with 4 x 4 mm round head wood screws with flat underside. The head must be 8 mm in diameter and in length 19 mm + the thickness of the plate on which the massage motor is mounted. Torque max. 2 Nm + resistance in the plate.
Mounted on one slat: The massage motor is mounted onto the slat by using 2 brackets 0761009 and 4 x M6 screws of a good quality. Inside the motor 4 self-locking nuts avoid the mounting screws to get loose.
Accessories: The TD3 can handle different kinds of accessories. The main types are: 1. LED Lightbox: A light unit 2. DC Connector: Connection possibilities of units with DC plugs 3. USB Connector: Connection possibilities with units with USB plugs 4. Bluetooth2LIN with this box connected you can use your iPad, iPhone or iPadtouch as a handset Cable for connection to the TD3 is a separate unit: 0617101, 205 mm long 1. LED Lightbox Just connect the LED Lightbox to the TD3 system via the motor cable.
Changing of batteries 1. Remove the battery cover (see Figure 1). 2. Use a blunt instrument to remove the battery. 3. Place 3 new batteries of the types R03 or LR03 (AAA) in the transmitter. Direction of how to place the batteries in the transmitter is shown in Figure 2 Figure 1 Figure 2 Emergency lowering function: (optional) Emergency lowering is meant for lowering the bed if a power failure occurs and the bed needs to be driven down into horizontal position.
Connection of emergency lowering: Please observe that if you order the TD3 with 2 x 9V batteries mounted, the batteries will not be connected. The customer needs to connect the cable from the battery drawer to the TD3 when installing the bed and connecting the mains. If the batteries are connected and the bed is not connected to the mains, the batteries will discharge in approx. 2 months and it will not be possible to perform an emergency lowering.
Welding the twist bracket on the frame 1) For the TD3 it is important that it is not welded on the outside of the twist bracket because there is not room for a welding seam in the motor housing. Instead weld the bracket on the whole length of its ends. 2) To maintain the correct angle of rotation of the headrest and the footrest it is important that the twist bracket is welded according to the below instructions.
Label for TD3 TWINDRIVE® System Label for LA27 Label for Massage Motor The shown TD3 label is an example for one model part number.
Disposal of LINAK products As LINAK customers often ask us how our products can be disposed of or scrapped we have prepared this guidance that enables a classification to different waste fractions for recycling or combustion. Guidance We recommend to disassemble our product into as many fractions as possible at the disposal and try to make it recycable. As examples of main groups within waste fractions we can mention: Metal, plastic, cable shoe, combustible waste and collection for recovery.
Main groups of disposal Product main groups Scrap Cable scrap Electronics scrap Plastic recycling or combustin LA27 X X X X TD3 X X X HB10RF X X X HB20RF X X X HC20RF X X X MD1 X X Comments The metals can be sorted for steel or aluminum X LED Lightbox X X X DC Connector X X X USB Connector X X X Bluetooth2LIN X X X can be chosen as accessories Disposal of batteries Details regarding safe disposal of used and leaking batteries: Batteries should be disposed in
DRAWING APPENDIX TWINDRIVE® TD3 System LA27 Page 37 of 44
HB12RF Hand Control HB20RF Hand Control HC20RF Hand Control Page 38 of 44
HC30 LED Lightbox 2 3 4 5 6 4 52.6 A 30 B 24 62 65 C 8.1 Material: Type: WE IMPROVE YOUR LIFE General Tolerance: Product: 2 3 Color: Producer: - - Date: Scale: Format: Sheet: Volume: General Surface Character: - - Name: Weight: accessory_lys.asm 31541 mm³ No.: 19-Aug-09 Ini: 1:1 ECO: A3 No. of 1/1 DD-Mmm-YY - check. dim. # Lifecycle state: ACCESSORY_LYS Rev.: Iter.
DC Connector 2 3 4 5 6 Ø4 52.6 A 30 63 29 B 65 C 8.1 2 3 USB Connector 4 WE IMPROVE YOUR LIFE 4 Color: Producer: General Tolerance: Product: - - Name: Scale: Format: Sheet: Volume: General Surface Character: - - Date: 5 Weight: accessory_dc.asm 33879 mm³ - 19-Aug-09 6Ini: 1:1 ECO: A3 No. of 1/1 DD-Mmm-YY - check. dim. # Lifecycle state: No.: ACCESSORY_DC Rev.: Iter.
Bluetooth2LIN Massage motor MD1 Page 41 of 44
Page 42 of 44
DECLARATION OF CONFORMITY LINAK A/S Smedevænget 8 DK - 6430 Nordborg hereby declares that LINAK Bluetooth receiver: BLUETOOTH2LIN001 complies with the Radio equipment and Telecommunications terminal equipment Directive 1999/5/EC: EN 300328 V1.7.7:2006, EN 301489-1 V1.9.
FACTORIES CHINA LINAK (Shenzhen) Actuator Systems, Ltd. Phone: +86 755 8610 6656 Fax: +86 755 8610 6990 E-mail: sales@linak.cn www.linak.cn DENMARK SLOVAKIA LINAK A/S - Group Headquarters, Guderup Phone: +45 73 15 15 15 Fax: +45 74 45 80 48 Fax: +45 73 15 16 13 (Sales) E-mail: info@linak.com www.linak.com LINAK Slovakia s.r.o. Phone: +421 51 75 63 414 Fax: +421 51 75 63 410 E-mail: jp@linak.sk www.linak.com USA LINAK U.S. Inc.