USER MANUAL TWINDRIVE ® TD3.2 / TD3.3 To learn more about LINAK please visit: W W W. L I N A K .
Contents Preface ................................................................................................................................................................. Important information ....................................................................................................................................... Safety instructions ..............................................................................................................................................
Preface We are delighted that you have chosen a product from LINAK A/S. LINAK systems are high-tech products based on many years of experience in the manufacture and development of actuators, electric control boxes, controls, and chargers. We are also constantly improving our products to meet customer requirements. This User Manual will tell you how to install, use, and maintain your LINAK TWINDRIVE® products. We are sure that the TWINDRIVE® products will give you many years of trouble-free operation.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Important information Important information on LINAK® products can be found under the following headings. Please read and understand these instructions for proper operation. Be sure to keep this instruction manual handy for future reference. Warning! Failure to comply with these instructions may result in accidents involving serious personal injury. Failing to follow these instructions can result in the product being damaged or being ruined.
Before start-up: • Make sure that the system has been installed as instructed in this User Manual. • Make sure that the voltage is correct before the system is connected to the mains. (See TD3 label on page 22). • System connection. The individual parts must be connected before connection to the mains. During operation • Take care that the cables are not damaged or get jammed. • The products must only be used in an environment, which corresponds to their IP protection or where no IP protection is required.
Misc. on the TD3 TWINDRIVE® system This system is a TWINDRIVE system developed for leisure beds and for indoor use in private homes. Warranty There is 36 months’ warranty on the TWINDRIVE® products against manufacturing faults calculated from the production date of the individual products (see label). LINAK A/S’ warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with. Furthermore, the system must not be exposed to violent treatment.
Mounting guidelines for the TWINDRIVE® system Place the TD3 below the twist brackets/“arms” of the bed Mount the TD3 and slide the closing devices over the gaps and make sure that the closing devices are in place before the TD3 is used.
Functional description Transmitter HB10: Up – down head motor Up – down foot motor Simultaneous up/down Transmitter HB20: Up – down head motor Up – down foot motor up to 3 extra channels common operation up/down (option) 1 2 Memory positions (3 positions) 3 S Store Button Light Button How to store • Drive to the desired position • Push “S” • Immediately afterwards the desired memory position must be pushed (1, 2 or 3) • The position is now stored Drive to stored memory position Push (1, 2 or 3) keep th
Handset for massage HB22RF2000 Usage: Enter/exit massage command mode Sets the control in massage mode for controlling the massage functions (LED flashing) or returns to normal mode for controlling the bed adjustment (LED off). Pressing this key has no influence on the TWINDRIVE unit except from waking it up to make its response time to massage commands shorter. If no keys are pressed for 10 min., the control will automatically go to normal mode (LED off).
Short key press on the right key turns off both massage motors no matter if they are running in a massage program, or separately. Keep key pressed to adjust the motor, change speed up or down (left key down, right key up.) Store and recall massage settings. 2 massage settings can be stored. Adjust the massage to the preferred settings. Pres the “S” key followed by either key “1” or “2”. To recall a pervious stored setting pres key “1” or “2”. In general Massage will turn off automatically 10 min.
Child lock To enable the function, the position of the switch in the front of the transmitter must be changed. To unlock the handset press up and down keys of the 2nd row at the same time for one sec. When the blue LED turns on the handset is unlocked for 10 sec. after last key press. Then it automatically locks again. If the up + down key is pressed for more than 2 sec. the handset will lock again.
Start-up - How to install the RF handset: Please be aware that if you use the TD3 for the first time or it has been disconnected from the mains, the receiver integrated in the TD3 needs approx. 20 sec. before being able to receive a signal. The TD3 can accept commands from up to 2 RF handsets. From the factory the TD3 cannot recognise any RF handsets at all and must be matched to the RF handset(s) by the end-user/bed manufacturer before these can control the TD3 operation.
Disturbance of RF signals: Please be aware that other equipments (as e.g. doorbells), which use the 433 MHz can disturb the RF signal. Under some circumstances it is not possible to run 2 or more TD3 at the same time. Please observe that if you place 2 beds/2 x TD3 at a distance below 0.8 m the RF signals they may interfere each other and the TD3’s can run irregularly. The min. distance between the TD3 must be 0.
Connections Ch.1 Ch.2 Ch.3 Mains inlet (HB connection) Battery cable/connection Battery drawer Reset Connection of massage motors: CH1 CH2 Footrest Headrest Connection of LA27 actuators: The TD3 will as default detect and run the LA27 using plug and play rules as illustrated in the table below. The idea is that the Headrest is the first actuator, the Footrest second and then Extra function.
Mounting instructions for the massage motor: Mounting on plate: Is mounted with 4 screws The massage unit is mounted with 4 x 4 mm round-head wood screws with flat underside. The head must be 8 mm in diameter and in length 19 mm + the thickness of the plate on which the massage motor is mounted. Torque max. 2 Nm + resistance in the plate.
Mounted on one slat: The massage motor is mounted on to the slat by using 2 brackets 0761009 and 4 x M6 screws of good quality. Inside the motor 4 self-locking nuts avoid the mounting screws to get loose.
Accessories: The TD3 can handle different kinds of accessories. The 3 main types are: 1. LED Lightbox : A light unit 2. DC Connector: Connection possibilities of units with DC plugs 3. USB Connector: Connection possibilities with units with USB plugs Cable for connection to the TD3 is a separate unit: 0617101, 205 mm long 1. LED Lightbox Just connect the LED Lightbox to the TD3 system via the motor cable. The light can be turned on and off via the handset. 2.
3. USB Connector Connect the USB Connector to the TD3 system via the motor cable. Before use the system must be configured via the TD3 configurator to be able to handle the mounted USB unit. The TD3 configurator is a PC software program. Via this unit you can connect a range of different accessories and gadgets with a USB plug, just as long as the device works in accordance with the general USB charger standard (max. 5V and supply max. 0.5A).
Changing of batteries 1. Remove the battery cover (see Figure 1). 2. Use a blunt instrument to remove the battery. 3. Place 3 new batteries type R03 or LR03 (AAA) in the transmitter. Press a button for 3 sec. If above procedure not is performed the handset will function anyway after app. 5 minutes.
Connection of Emergency lowering: Please observe that if you order the TD3 with 2 x 9V batteries mounted, the batteries will not be connected. The customer needs to connect the cable from the battery drawer to the TD3 when installing the bed and connecting the mains. If the batteries are connected and the bed is not connected to the mains, the batteries will discharge in approx. 2 months and it will not be possible to perform an emergency lowering.
Welding the twist bracket on the e frame 1) For the TD3 it is important that it is not welded on the outside of the twist bracket because use there is not room for a welding seam in the motor housing. Instead weld the brackett on the whole length of its ends. 2) To maintain the correct angle of rotation otation of the headrest and the foot rest itt is important that the twist bracket is welded according to the below instructions. ns.
Label for TD3 TWINDRIVE® System Label for Massage Motor Label for HB12 The shown TD3 label is an example for one model part number.
Disposal of LINAK’s products As LINAK’s customers often ask us how our products can be disposed of or scrapped we have prepared this guidance that enables a classification to different waste fractions for recycling or combustion. Guidance We recommend to disassemble our product into as many fractions as possible at the disposal and try to make it recycable. As examples of main groups within waste fractions we can mention: Metal, plastic, cable shoe, combustible waste, and collection for recovery.
Main groups of disposal Product main groups Scrap Cable scrap Electronics scrap Plastic recycling or combustin LA27 X X X X TD3 X X X HB10 X X X HB20 X X X MD1 X X Comments The metals can be sorted for steel or aluminum X LED Lightbox X X X DC Connector X X X USB Connector X X X Disposal of batteries. Details regarding safe disposal of used and leaking batteries: Batteries should be disposed in accordance with appropriate federal, state and local regulations.
DRAWING APPENDIX TWINDRIVE® TD3 System LA27 27
HB10 Transmitter HB20 Transmitter Massage motor otor MD1 28
LED Lightbox 52.6 4 30 24 62 65 8.1 DC Connector 52.6 Ø4 30 29 63 65 8.
USB Connector 52.6 4 30 29 63 65 8.
LINAK APPLICATION POLICY The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware, software, technical advice, etc. related to an existing or new customer application. LINAK products as defined above are applicable for a wide range of applications within the Medical, Furniture, Desk, and Industry areas.
FACTORIES CHINA LINAK (Shenzhen) Actuator Systems, Ltd. Phone: +86 755 8610 6656 . Fax: +86 755 8610 6990 E-mail: sales@linak.cn . www.linak.cn NORWAY LINAK Norge AS Phone: +47 32 82 90 90 . Fax: +47 32 82 90 98 E-mail: info@linak.no . www.linak.no IRAN Bod Inc. Phone: +98 21 2203 9435 . Fax: +98 21 2203 9430 E-mail: info@bod.ir . www.bod.ir DENMARK LINAK A/S . Group Headquarters Guderup Phone: +45 73 15 15 15 . Fax: +45 74 45 80 48 Fax (Sales): +45 73 15 16 13 E-mail: info@linak.com . www.linak.