0 INSTALLATION INSTALLATION Before Installing Installation Overview Please read the following installation instructions first after purchasing this product or transporting it to another location.
INSTALLATION 11 Parts Parts Provided © Anti-tip bracket (1 ea) @ Screws (6 ea) @ Anchors (6 ea) © Template (1 ea) Parts Not Provided © 4-wire cord or 3-Wire cord (UL approved 40 or 50 AMP) @ Strain relief (for conduit installations only} NOTE Observe all governing codes and ordinances. Have the installer show you the location of the circuit breaker or fuse. Mark it for easy reference. As when using any appliance generating heat, follow common-sense safety precautions.
12 INSTALLATION Choosing the Proper Location Dimensions and Clearances Dimensions Dimensions LTEL7337% A Width 2917/8" (758.8 mm) B Height 36 1/2" (927.9 mm) Cc Depth {Includes Door Handle) 2917/64" (743.2 mm) D Height (Excludes Vent Trim) 36" (913.0 mm) E Depth es ony she on” that is loaded into the cabinet. (629.4 mm) F Depth (Excludes Door Handle) 26 7/8" (683 mm) G Depth when upper door is fully opened 385/8" (981.2 mm) H Depth when lower door is fully opened 427/32" (1072.
INSTALLATION 13 ® Minimum clearance to left/right wall cm) © Maximum depth for cabinets above counter tops 13" (33.0 cm) i © Front edge of the range side panel forward from cabinet 21/4" (63cm) 2 © To cabinets below cook top and at the range back 0" E @ Minimum opening in overhead cabinets 30" (76.2 cm) = @ Minimum distance from counter top to overhead cabinets at side 18" {45.7 cm) © Height of counter top 36" (91.3 cm) NOTE = @ 30" (76.
14 INSTALLATION Electricity The range should always be plugged into its own individual properly grounded electrical outlet. » This prevents overloading house wiring circuits which could cause a fire hazard from overheated wires. = Iris recommended that a separate circuit serving only this appliance be provided. Flooring 4. CAUTION + Use an insulated pad or 1/4 in. {0.64 cm) plywood under the range if installing the range over carpeting.
INSTALLATION 15 All wiring should conform to local and NEC codes. This range requires a single-phase, 3 wire, AC 120/ 208 V or 120/240 V 60 Hz electrical system. Use only a 3-conductor or a 4-conductor UL listed range cord with closed-loop terminals, open-end spade lugs with upturned ends or similar termination. Do not install the power cord without a strain relief. A range cord rated at 40 amps with 120/240 minimum volt range is required.
16 INSTALLATION in. (2.8 cm) conduit hole @ instead of the 1 3/8 in. (3.5 cm) power cord hole @. For power cord @ installations, hook the strain relief over the 1 3/8 in. (3.5 cm) power cord hole located below the rear of the oven, Insert the power cord through the strain relief and tighten it. For conduit installations, insert the conduit strain relief in the 1 1/8 in. (2.8 cm) conduit hole. Then install the conduit through the body of the strain relief and fasten the strain relief with its ring.
INSTALLATION 17 © Red @ Terminal Block @ Cord/Conduit Connection Plate 4-Wire Connection: Power Cord £4 WARNING Only a 4-conductor power-supply cord kit rated 120/240 volts, 50 amperes and marked for use with ranges with closed-loop connectors or opened spade lugs with upturned ends must be used. The white middle {neutral) wire of the power cord or 4-wire conduit has to be connected to the middle post of the main terminal block.
18 INSTALLATION 2 Prepare the conduit wires as shown below. 1 a" Sem) 5 {0.2 em} Ey @ Cord/Conduit connection plate 3 install the conduit strain relief. 1) Insert the strain refinement 1 1/8in. (2.8 cm) conduit hole. 2) Install the conduit through the body of the strain relief and fasten the strain relief with its ring. NOTE * For conduit installations, purchase a strain relief, 4 Reinstall the cord/conduit connection plate. Conduit Connections If the wire In the conduit Is copper It must AWG wiring.
INSTALLATION emi (0.8 om "RE 89cm} @ Cord/Conduit Connection Plate @® Ground Wire 3 install the conduit strain relief. 1) Insert the strain refinement 1 1/8in. (2.8 cm) conduit hole. 2) Install the conduit through the body of the strain relief and fasten the strain relief with its ring. IRE IRE IRE EEE NOTE « For conduit installations, purchase a strain relief. 4 Reinstall the cord/conduit connection plate. Conduit Connections If the wire in the conduit is copper it must AWG wiring.
20 INSTALLATION EY NOTE + If the counter top depth is less than 24 3/4", the control panel will not sit flush with the counter top. 1 Using a screwdriver, remove the three screws holding the rear top plate in place. @ Rear Top Plate 2 attach the rear top plate and filler assembly as shown, using three screws removed in step 1. @ Rear filler Anti-tip Device Installing the Anti-tip Device Tip Hazard £5 WARNING + A child or adult can tip the range and be killed.
INSTALLATION 21 @ Leveling Leg 1 Slide the range against the wall, making sure the back leg slides into and engages the anti tip bracket. Check for proper installation by grasping the front edge of the cook top and carefully attempting to tilt the range forward. Test Run Test the Range Before Use Check if the range is properly installed and run a test cycle. 1 Before using the cook top for the first time, clean it with a ceramic cook top cleaner. This helps protect the top and makes cleanup easier.